BBiasi logo

Biasi ER07 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi ER07 fault code mean?

The ER07 code appears on Biasi boilers when the control board detects a problem with the domestic hot water (DHW) temperature probe. The PCB continuously monitors readings from this probe to keep the boiler operating safely within its designed temperature range. When those readings fall outside acceptable limits — or stop arriving altogether — the boiler triggers a safety lockout and shuts itself down to prevent further internal damage. The fault is closely related to ER06, which covers the central heating probe; ER07 is specifically the hot water side. If your display is showing multiple error codes alongside ER07, this can point to a broader issue affecting all temperature sensing, such as a circulation problem or a faulty PCB. Note: a small number of industry sources describe ER07 as an ignition lockout, but the large majority of specialist references consistently identify it as a DHW probe fault — that is the definition used here.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check for other visible issues first DIY safe

    Before calling anyone out, note whether any other error codes are showing alongside ER07, whether you have hot water or heating at all, and whether the boiler has been making any unusual noises. This information will help an engineer diagnose the fault more quickly.

  2. Attempt a single boiler reset DIY safe

    Locate the reset button on your Biasi boiler (usually a dedicated button or a turn-and-hold function on the control dial — check your user manual for the exact method on your model). Hold it as directed and see whether the boiler fires up normally. If it restarts but the code returns within a short time, there is an underlying fault that reset alone will not cure. Do not reset more than two or three times.

  3. Have a Gas Safe engineer test the DHW probe and its wiring Gas Safe engineer

    An engineer will remove the boiler casing — which legally must be done by a Gas Safe registered professional — and use a multimeter to measure the resistance of the DHW temperature probe against the manufacturer's specification. They will also check every connector and length of wiring on that circuit. Loose connections can sometimes be re-secured without replacement; damaged wiring sections may be repaired rather than fully replaced.

  4. Replace the DHW temperature probe if defective Gas Safe engineer

    If multimeter readings confirm the probe is out of specification, the engineer will fit a new compatible DHW temperature probe and clear the fault code. After replacement the boiler should be run through a full hot water demand cycle to confirm the code does not return.

  5. Inspect and flush the system if circulation is restricted Gas Safe engineer

    Where sludge or limescale is suspected, the engineer may recommend a power flush or hot chemical flush of the system. This involves circulating cleaning agents at elevated temperature to break down deposits, followed by a full drain-down. After flushing, a central heating inhibitor should be added and a magnetic system filter fitted to prevent recurrence.

  6. Assess the PCB if all other components test correctly Gas Safe engineer

    If the probe, wiring, and circulation all check out, the engineer will turn their attention to the PCB. A faulty board will need to be replaced. Given the cost of a Biasi PCB (typically £300–£500 for the part), the engineer may discuss whether repair or a new boiler installation represents better value, particularly for older appliances outside warranty.

  7. Contact a Gas Safe registered engineer if the code persists Gas Safe engineer

    ER07 is not a fault that can be cleared by a homeowner beyond a reset. If the code keeps returning or if you have not yet had a professional inspection, book a Gas Safe registered engineer to carry out a full diagnosis. You can find registered engineers at the Gas Safe Register website (gassaferegister.co.uk).

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £140–£350, depending on the underlying cause.

Frequently asked questions

Can I fix the Biasi ER07 fault myself?

Not in any meaningful way, unfortunately. The only things you can safely do as a homeowner are attempt a reset (no more than two or three times) and make a note of any other codes on the display. Diagnosing or replacing the DHW temperature probe, testing the wiring, flushing the system, or touching the PCB all require the boiler casing to be removed — and working inside a gas appliance is legally restricted to Gas Safe registered engineers in the UK.

How much does it cost to fix ER07 on a Biasi boiler?

Most people with this fault end up paying between £140 and £350, which covers the engineer's call-out and labour plus a replacement DHW temperature probe or wiring repair. If the system needs a power flush to clear sludge or limescale, expect to add £300–£500 to that depending on the number of radiators. PCB replacement is a less common but more expensive outcome, typically £400–£600 all-in for a Biasi board — at that point it is worth discussing the boiler's age and whether a replacement boiler makes more financial sense.

Will resetting the boiler clear ER07 permanently?

A reset may clear the code temporarily, but if there is an underlying fault with the DHW probe, its wiring, or another component, the code will return — often within the same heating or hot water cycle. Repeatedly resetting without fixing the root cause will not resolve the fault and could mask a developing problem. If the code comes back after one or two resets, call a Gas Safe engineer.

Is ER07 covered under my Biasi warranty?

Biasi boilers typically carry a manufacturer's warranty of five to seven years depending on the model and registration. If your boiler is within that period, contact Biasi directly or the installer who fitted it before arranging an independent repair, as using an unauthorised engineer for warranty work can sometimes affect your cover. If you are outside the warranty period, any Gas Safe registered engineer can carry out the repair.

Affected models: Biasi Riva Plus, Biasi Riva Advance, Biasi Garda, Biasi Parva, Biasi Inovia

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi ER07 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →