Buderus 9L 238 Fault Code: Causes, Fixes & Repair Costs

What does the Buderus 9L 238 fault code mean?

The 9L fault family on Buderus boilers relates to an electrical problem with the gas valve circuit — specifically, the boiler's control electronics cannot confirm that the gas valve coil or its associated wiring is functioning correctly, so the boiler shuts down as a safety precaution. The three-digit sub-code 238 narrows the diagnosis toward a fault with the UBA 3 (Universal Burner Automator) or KIM (combustion identification module) rather than a simple cable break. A closely related sub-code, 9L 234, is specifically described by Buderus as a faulty gas burner fitting cable connection; if you see 234 rather than 238 on your display, the wiring harness to the valve is the more likely culprit before the UBA board itself. In both cases the boiler locks out until the underlying electrical issue is resolved. This is not a fault a homeowner can repair — all diagnostic and corrective work must be carried out by a Gas Safe registered engineer.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Do not reset the boiler more than two or three times DIY safe

    Pressing reset repeatedly when the burner is failing to start risks damaging the ignition transformer. Attempt a single reset; if the fault returns immediately, stop and move on to calling an engineer rather than cycling the reset button further.

  2. Check that your gas supply is available DIY safe

    Confirm that other gas appliances in the property (hob, gas fire) are working normally. If there is no gas elsewhere, contact your gas supplier — this is not a boiler fault. If gas is available to other appliances, the issue is within the boiler itself.

  3. Inspect and reseat the gas valve wiring connectors — engineer only Gas Safe engineer

    A Gas Safe engineer will disconnect power, remove the boiler casing, and carefully unplug and re-seat the connector block at the gas valve. They will visually inspect each terminal for signs of burning, corrosion, or pushed-back pins and clean or replace terminals as required.

  4. Measure gas valve coil resistance — engineer only Gas Safe engineer

    Using a calibrated multimeter set to the lowest ohm range, the engineer will measure the resistance across the valve coil terminals. A reading outside the 18–55 ohm range indicates a defective coil. They will also check each wire in the loom for continuity and test between wires for any short circuits.

  5. Perform live voltage measurement at the gas valve — engineer only Gas Safe engineer

    While the fault operating code is active, the engineer will use a volt-ohm meter to confirm that 20–24 V DC is present at the gas valve plug — between the central and left contacts, and between the central and right contacts. Absence of voltage at this point shifts suspicion toward the UBA or PCB rather than the valve itself.

  6. Trial substitution of the UBA board — engineer only Gas Safe engineer

    If wiring and valve coil are both confirmed good, the engineer may temporarily connect a known-working UBA to determine whether the original board is the source of the fault. If the substitute UBA clears the fault, the original unit should be replaced. The engineer will need to restore all user settings on the room controller after fitting a new UBA.

  7. Replace defective components as indicated — engineer only Gas Safe engineer

    Depending on findings, the engineer will replace the gas valve coil or complete valve assembly, the UBA 3 board, or — if all other components test correctly — the main PCB. Only Gas Safe registered engineers may carry out work on gas components.

  8. Call a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    All of the diagnostic and repair steps above require a Gas Safe registered engineer. If you have not already booked one, do so now. Have your boiler model number and the full fault code (9L 238 or 9L 234) ready when you call so the engineer can bring likely replacement parts.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£400, depending on the underlying cause.

Frequently asked questions

Can I fix a Buderus 9L 238 fault myself?

No. The 9L 238 fault involves the gas valve circuit and associated control electronics. Any work on gas components is legally required to be carried out by a Gas Safe registered engineer in the UK. You can safely check that your gas supply is working and attempt a single boiler reset, but beyond that the diagnosis and repair must be left to a qualified professional.

What is the difference between fault codes 9L 238 and 9L 234?

Both codes belong to the same 9L fault family relating to the gas valve electrical circuit. Buderus describes 9L 234 specifically as a faulty cable connection at the gas burner fitting — so if your display shows 234, the wiring harness or connectors are the most likely culprit. Sub-code 238 points more toward a defect in the UBA 3 control board or KIM module itself, though wiring should always be ruled out first before replacing the UBA.

How much does it cost to fix a Buderus 9L 238 fault in the UK?

Most repairs fall in the range of £150–£400 including parts and labour. Wiring reconnection or a terminal clean at the lower end, a gas valve replacement typically £180–£280, and a UBA board replacement around £250–£400. If the main PCB turns out to be the root cause, costs can rise higher — typically £300–£500 or more — but PCB failure is a less common outcome for this particular fault code.

Will resetting my Buderus boiler clear the 9L 238 fault?

Occasionally a transient voltage spike can trigger a 9L 238 code that clears after a single reset. However, you should not press reset more than two or three times in succession — doing so risks damaging the ignition transformer. If the fault returns after one or two resets, stop resetting and contact a Gas Safe engineer, as repeated resets will not resolve an underlying wiring or component fault and may cause additional damage.

Does replacing the UBA board erase my boiler settings?

Yes. Buderus confirms that fitting a new UBA 3 board resets all user-defined parameters stored in the control unit, including any settings programmed via a room controller such as the RC30 or RC35. Ask your engineer to note your current settings — heating schedules, hot water temperatures, and so on — before replacing the board so they can be reprogrammed afterwards.

Affected models: Buderus GB162, Buderus GB172, Buderus GB192, Buderus Logamax Plus GB162, Buderus Logamax Plus GB172

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Buderus 9L 238 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →