Buderus 9P 239 Fault Code: Causes, Fixes & Repair Costs

What does the Buderus 9P 239 fault code mean?

The 9P fault code (display value 239) appears on Buderus boilers when the main controller cannot successfully read or communicate with the KIM — the Key Identification Module. The KIM is a small EEPROM-based identification chip that sits on the DBA control panel circuit board. It holds configuration data the boiler needs to operate correctly, so if it cannot be detected — whether due to a loose connection, a short circuit at its contacts, or a defective control board — the boiler locks out and displays 9P. In short, the boiler's brain cannot recognise its identity chip, and it refuses to run until the issue is resolved.

Lockout — engineer likely May need a Gas Safe engineer 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Switch the boiler off at the power switch and wait 30 seconds, then switch it back on DIY safe

    A temporary power interruption can sometimes clear a transient communication glitch between the controller and the KIM. This is the quickest first step. If the 9P code disappears and does not return, monitor the boiler over the next few days.

  2. Attempt a boiler reset — but no more than two or three times DIY safe

    On most Buderus models there is a Reset button on the front panel. Press and hold it for approximately five seconds. Do not reset more than two or three times in succession — repeated resets when the burner will not start can damage the ignition transformer. If the fault returns immediately or will not clear, stop resetting and move on.

  3. Check that the gas supply to the boiler is turned on and other gas appliances in the property work DIY safe

    While 9P is not a gas-pressure fault, it is worth ruling out a general supply interruption before calling an engineer. Check whether your gas hob or other appliances light normally. If there is no gas supply, contact your gas supplier.

  4. Have a Gas Safe engineer inspect and reseat the KIM module Gas Safe engineer

    The KIM sits on the DBA board inside the boiler casing. An engineer will isolate the boiler from the mains, open the casing, and carefully reseat the KIM in its connector, ensuring it is fully and correctly engaged. This alone resolves many 9P faults at minimal cost. If reseating clears the code, the engineer will run functional checks before leaving.

  5. If reseating does not resolve the fault, have the KIM module tested and replaced if necessary Gas Safe engineer

    The engineer can test the KIM independently. If it has failed — which can happen due to age, moisture, or an electrical spike — a replacement KIM is the next step. This is a relatively low-cost component compared to a full board replacement and should always be tried before condemning the PCB.

  6. Have the DBA control board (PCB) inspected and replaced if found to be defective Gas Safe engineer

    If the KIM is confirmed good but the 9P fault persists, the DBA control board itself is likely defective. The engineer will check for visible damage such as burnt tracks, failed components, or moisture. If the board is beyond repair, a replacement board will need to be sourced, fitted, and correctly configured for your specific boiler model. PCB work involves connections to the gas valve and safety controls and must only be carried out by a Gas Safe registered engineer.

  7. Ask your engineer to verify the mains voltage and earthing at the boiler Gas Safe engineer

    If neither the KIM nor the PCB is found to be obviously damaged, intermittent 9P faults may point to an electrical supply problem. The engineer can check incoming voltage and confirm the earth connection is solid, which may require liaison with a qualified electrician if the consumer unit or building wiring is at fault.

  8. Contact a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    If the steps above have not resolved the fault, or if you are unsure about any aspect of the diagnosis, book a Gas Safe registered Buderus specialist. They will have access to manufacturer diagnostic tools and the correct replacement parts. You can find Gas Safe registered engineers at the official Gas Safe Register website (gassaferegister.co.uk).

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£450, depending on the underlying cause.

Frequently asked questions

Can I fix the Buderus 9P fault myself?

The only safe DIY steps are switching the boiler off and on, attempting a reset (no more than two or three times), and checking your gas supply is on. Everything else — opening the boiler casing, reseating or replacing the KIM, or inspecting the PCB — must be done by a Gas Safe registered engineer. The control board is connected to the gas valve and safety systems, and working on it without Gas Safe registration is both illegal and dangerous.

How much does it cost to fix a Buderus 9P fault in the UK?

If the KIM simply needs reseating, you may only pay the engineer's callout and labour charge — typically £80 to £150 depending on your region. A KIM replacement adds around £45 in parts. If the full DBA control board needs replacing, expect to pay £300 to £450 all-in for parts and labour, though costs can be higher in London and the South East. A specialist PCB repair service is worth considering for boards that show physical damage — these typically charge £80 to £120 and often provide a 12-month warranty on the repair.

Is it worth replacing the PCB on an older Buderus boiler?

If your boiler is under eight years old and otherwise in good condition, a PCB replacement is generally a sensible repair. On a boiler that is ten years old or more, especially one that has had other component failures, it is worth weighing the repair cost (£300–£450 or more) against the cost of a new installation. A new combi boiler typically costs £1,800–£3,000 installed, so on an ageing boiler the sums can sometimes favour replacement — particularly when you factor in improved efficiency and a fresh warranty.

What is the KIM module on a Buderus boiler?

KIM stands for Key Identification Module. It is a small EEPROM chip mounted on the DBA control panel board inside the boiler. It stores identification and configuration data that the main controller needs in order to recognise the boiler's specification and operate safely. Without a working KIM that the controller can read, the boiler will lock out and display the 9P fault code. It is a relatively inexpensive component, so an engineer will always try replacing just the KIM before moving on to replacing the entire control board.

Affected models: Buderus GB172, Buderus GB192, Buderus GB212, Buderus GB162, Buderus Logamax Plus GB172, Buderus Logamax Plus GB192, Buderus GB125, Buderus GB315

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer