Chaffoteaux 112 Fault Code: Causes, Fixes & Repair Costs

What does the Chaffoteaux 112 fault code mean?

Fault code 112 on a Chaffoteaux boiler indicates that the PCB has detected a problem with the NTC thermistor monitoring the water temperature at the inlet of the main heat exchanger. The boiler's control board is receiving either no signal at all (open circuit) or a garbled, out-of-range signal (short circuit) from this sensor, so it shuts down as a precaution to prevent overheating or unsafe operation. In plain terms, the boiler can no longer trust the temperature reading at the point where water enters the heat exchanger, and it will not fire until the issue is resolved.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once or twice DIY safe

    Press and hold the reset button on the boiler's front panel as described in your user manual. Fault 112 can occasionally be triggered by a brief, transient signal dropout rather than a true component failure. If the boiler fires up normally and stays running without the code returning, monitor it over the next day or two. If the code comes back, move on to the steps below.

  2. Check that the boiler's external electrical supply is stable DIY safe

    Make sure the boiler's isolator switch is on and that no relevant circuit breakers in your consumer unit have tripped. A power interruption can sometimes cause a spurious sensor fault on restart. This takes only a moment to verify before calling an engineer.

  3. Have a Gas Safe engineer inspect the sensor wiring and connectors Gas Safe engineer

    An engineer will isolate the boiler electrically, then trace the wiring between the heat exchanger inlet sensor and the PCB. They will check for visible damage, corrosion, chafed insulation, and loose or damp connector plugs. Many fault 112 cases are resolved at this stage simply by cleaning a connector or replacing a short section of damaged wire.

  4. Have the engineer test the NTC thermistor with a multimeter Gas Safe engineer

    The NTC thermistor has a known resistance-to-temperature relationship. At room temperature a healthy sensor typically reads in the range of several kilohms; the resistance drops predictably as temperature rises. If the reading is open-circuit (infinite resistance) or zero ohms, the sensor has failed and needs replacing. Compatible replacement sensors for Chaffoteaux boilers are widely available and relatively inexpensive.

  5. Have the engineer replace the inlet NTC thermistor if faulty Gas Safe engineer

    Once confirmed faulty, the engineer will fit a replacement sensor, reconnect all wiring securely, and run the boiler through a full heating cycle to verify the fault code does not return. They will also check that the new sensor's readings are tracking correctly on the boiler's diagnostic menu if one is available.

  6. If the sensor and wiring are both healthy, have the PCB assessed Gas Safe engineer

    A correctly wired, in-specification sensor that still produces fault 112 points toward a PCB input fault. The engineer may try a known-good sensor as a swap test before concluding the PCB is the problem. PCB replacement or specialist repair is a more significant job and cost, so it is worth ruling out every other cause first.

  7. Call a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    All the diagnostic and repair work described above must be carried out by a Gas Safe registered engineer. You can verify an engineer's registration at gassaferegister.co.uk. Do not attempt to access internal boiler components, test live wiring, or replace parts yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£280, depending on the underlying cause.

Frequently asked questions

Is fault code 112 dangerous — should I keep using the boiler?

The boiler will typically lock itself out when fault 112 appears, so it will not fire while the code is active. This is a safety feature rather than a sign of immediate danger such as a gas leak. That said, you should not attempt to repeatedly reset and force the boiler to run if it keeps locking out on the same fault. Leave it off and arrange for a Gas Safe engineer to visit.

How much does it typically cost to fix Chaffoteaux fault code 112 in the UK?

For most households the repair comes in between £100 and £280. The sensor itself is inexpensive — usually £10–£25 for the part — but you are also paying for the engineer's call-out and labour, which typically runs £60–£120 depending on your region and the engineer. London and the South East tend to be 15–25% higher than the national average. If the root cause turns out to be the PCB rather than the sensor, costs rise significantly — a replacement PCB for a Chaffoteaux boiler can cost £200–£350 for the part alone plus labour, so it is worth getting the sensor and wiring checked thoroughly first.

Can I replace the NTC thermistor myself to save money?

It is strongly recommended that you do not. While the sensor itself is not a gas component, accessing and replacing it involves working inside the boiler casing with live electrical circuits and pressurised water connections. Under UK law, Gas Safe registration is not required for sensor replacement specifically, but errors during the work could damage the boiler, cause a water leak, or create an electrical hazard. More practically, most boiler manufacturers and home insurers expect service work to be carried out by a competent heating engineer. The labour cost for a straightforward sensor swap is usually modest, so the saving from a DIY attempt is small relative to the risk.

The fault cleared after a reset but keeps coming back — what does that mean?

An intermittent fault 112 that clears temporarily after a reset but returns within hours or days suggests the sensor or its wiring is on the way out rather than having failed completely. A thermistor that is beginning to break down internally can produce correct readings when cold but drop out once it warms up, or it may have a hairline break in its wiring that only opens under vibration or thermal expansion. An engineer can monitor the sensor's live resistance readings through a heating cycle to catch intermittent faults that would not show up on a cold static test.

Affected models: Chaffoteaux Pigma, Chaffoteaux Mira, Chaffoteaux Alixia, Chaffoteaux Serelia, Chaffoteaux Niagara

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Chaffoteaux 112 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →