Chaffoteaux 116 Fault Code: Causes, Fixes & Repair Costs

What does the Chaffoteaux 116 fault code mean?

Fault code 116 on Chaffoteaux boilers signals that the manual-reset safety thermostat on the underfloor heating circuit has tripped open. This thermostat acts as a last line of defence against overheating — it cuts the electrical circuit and triggers a boiler shutdown when the underfloor circuit temperature climbs beyond a safe threshold (typically around 55–60°C). Because this is a manual-reset device, the boiler will remain locked out until the thermostat is physically reset at the manifold or control box, and the underlying cause is identified. The closely related code E30 (seen on older Chaffoteaux & Maury models without a numeric display) describes the same condition. Newer display-equipped models — including the Urbia Green, Mira C Green, Serelia Green, and Niagara Green — show 116 instead.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Locate and manually reset the underfloor heating safety thermostat DIY safe

    The manual-reset thermostat is normally situated on or near the underfloor heating manifold or its control enclosure — look for a small button, often red or white, that can be pressed in with a finger or a fine tool. The boiler will not restart until this is done. Before pressing it, allow a few minutes for the system to cool down.

  2. Reset the boiler once DIY safe

    After resetting the floor thermostat, press the boiler's reset button once and observe whether it fires up and stays running. If the fault reappears promptly, do not continue resetting — repeated lockouts without addressing the root cause will not resolve the problem and may mask a worsening issue.

  3. Check that the underfloor heating pump is running DIY safe

    With the heating on, place a hand on the pump body and listen for a faint hum or feel for vibration. Complete silence and no warmth suggest the pump is not spinning. After a long summer shutdown, pumps can seize due to limescale on the rotor shaft — an engineer can free the rotor using the manual bleed screw on the pump head.

  4. Verify the underfloor circuit flow temperature setting DIY safe

    Check the boiler's controls or the blending valve setting to confirm the underfloor circuit is being supplied with water no hotter than 45–50°C. If your installation mixes underfloor and radiator circuits from the same boiler without a dedicated blending valve, inform the engineer — fitting one may be needed.

  5. Inspect the system for signs of sludge or poor circulation DIY safe

    Cold patches in the floor, gurgling sounds from pipework, or other heating zones also underperforming can all point to a circulation blockage. Note these symptoms before calling an engineer — the information will help them diagnose quickly.

  6. Call a Gas Safe registered engineer to investigate and carry out repairs Gas Safe engineer

    Any work on the boiler's internal components — including the flow sensor, pump replacement, blending valve installation, or PCB — must be carried out by a Gas Safe registered engineer. They can also test the underfloor thermostat for continuity, check sensor accuracy, and arrange a power flush if sludge is identified. Always ask to see their Gas Safe ID card before work begins.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£350, depending on the underlying cause.

Frequently asked questions

Why won't my Chaffoteaux boiler restart even after pressing the reset button?

Fault code 116 uses a manual-reset safety thermostat on the underfloor heating manifold — this is separate from the boiler's own reset button. You need to physically press the reset button on the thermostat unit itself (usually located at the manifold or its control box) before the boiler's reset will work. If the boiler still locks out again shortly after, there is an underlying issue — most likely a pump fault or excessive flow temperature — that needs a Gas Safe engineer to diagnose and fix.

Is Chaffoteaux fault code 116 the same as error E30?

Yes, they describe the same condition. E30 is the alphanumeric code shown on older Chaffoteaux & Maury boilers that have a simpler display, while 116 is the numeric equivalent displayed on newer models such as the Urbia Green, Mira C Green, Serelia Green, and Niagara Green. Both indicate that the underfloor heating circuit's safety thermostat has tripped open due to overheating.

How much does it cost to fix a Chaffoteaux 116 fault in the UK?

Most people with this fault pay somewhere between £100 and £350. A straightforward thermostat reset plus investigation by an engineer typically costs £100–£180 including callout. If the circulation pump needs replacing, expect £200–£350 in parts and labour combined. A power flush to clear sludge from the underfloor circuit can add £300–£500 on top if blockage is found to be the root cause — though that is less common. Major boiler-side components such as a PCB, if found to be involved, can push costs higher, but that would be unusual for this specific fault.

Can I prevent fault code 116 from coming back every autumn when I switch the heating on?

Yes — seasonal maintenance goes a long way. Before switching your heating on after a long summer break, check that the underfloor heating pump spins freely (an engineer can manually free a seized rotor), bleed any air from the underfloor loops, and confirm the blending valve or temperature settings are still correct. Having the system serviced annually by a Gas Safe engineer keeps all these components in check and catches deteriorating parts before they trigger a safety shutdown.

Affected models: Urbia Green, Mira C Green, Serelia Green, Niagara Green, Chaffoteaux & Maury (E30 equivalent on older models)

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Chaffoteaux 116 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →