Ariston 116
Ariston fault code 116 points to a problem with the room temperature sensor circuit or, on certain models, an open floor thermostat circuit. The boiler has detected that the signal from the room sensor (NTC) is missing or out of range — either because the sensor has failed, the wiring has lost continuity, or the circuit has opened. On most modern Ariston combis and system boilers this is a room temperature sensor fault (similar in nature to code 114, which covers the outdoor sensor). On some older models such as the Clas HE R, the code specifically flags a floor thermostat contact open condition, meaning the underfloor heating thermostat circuit is not completing properly. In both interpretations the boiler may refuse to fire for heating until the circuit is restored, but this is not a gas safety emergency.