Baxi E.01-.12
Baxi's E-series codes are permanent lockout faults — the boiler has shut itself down and will not restart until the underlying problem is resolved and the reset button is pressed manually. The two-part number after the dot narrows the fault right down: for example, E.01–.04 means repeated flame loss, E.01–.11 points to a fan speed problem, E.02–.07 flags low system pressure, and E.04–.08 indicates the boiler has reached an unsafe temperature. All codes in the E.01–E.12 family work the same way — the boiler locks out, displays the code, and waits. Common sub-codes you may see include: E.01–.02 (return sensor reading higher than flow sensor), E.01–.04 (flame lost five times in 24 hours), E.01–.05 (return temperature sensor open-circuit), E.01–.11 (incorrect fan speed or draught), E.01–.12 (return temp greater than flow temp), E.01–.17 (no circulation detected), E.01–.20 (flue gas temperature above 140°C), E.02–.07 (low or no system water pressure), E.02–.16 (onboard control unit time-out — possible PCB damage), E.02–.17 (communication lost between gas valve and PCB), E.04–.01 (flow sensor short-circuit), E.04–.02 (flow sensor open-circuit), E.04–.03 (critically high flow temperature due to poor circulation), E.04–.04 (flue temperature sensor short-circuit), E.04–.08 (maximum safe temperature reached — safety thermostat open), and E.04–.10 (failure to ignite — check gas supply).

