Glow-worm F24
The F24 code appears when your Glow-Worm boiler detects that the water temperature in the heating circuit is climbing far more rapidly than it should. Under normal operation, the water temperature increases gradually as the boiler fires; when it surges upward too quickly, the flow pipe NTC thermistor picks this up and sends a signal to the PCB, which locks the boiler out to prevent overheating. On certain Glow-Worm models the fault is triggered specifically when the central heating return temperature exceeds 90°C, but the root cause is the same either way: heat generated inside the boiler is not being dispersed into the heating system quickly enough, usually because water is not circulating properly. This is a safety lockout and should not be ignored or repeatedly reset without investigating the underlying cause.