Saunier Duval F.24 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.24 fault code mean?

The F.24 code indicates that your Saunier Duval boiler has detected little or no water flowing through the central heating circuit. To protect its internal components from overheating or running dry, the boiler locks out and shuts down, leaving you with no heating or hot water until the underlying problem is resolved. Because Saunier Duval is part of the Vaillant Group and shares the same control architecture, this code carries the same meaning across both brands. The boiler will need to be reset once the root cause has been addressed, though repeated resets without fixing the fault will not clear it permanently.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge on the boiler DIY safe

    Look at the pressure gauge or manometer on the boiler front. If the reading is below 1.0 bar, the system is likely under-pressurised. Top up slowly using the filling loop until the needle reaches between 1.0 and 1.5 bar, then close the filling loop valves fully. Do not overfill beyond 2.0 bar.

  2. Inspect isolation valves around the boiler and pump DIY safe

    Trace the pipework immediately around the boiler and pump. Isolation valves (typically with a flat-head slot on the body) should be turned so the slot runs parallel with the pipe, indicating they are fully open. If any are perpendicular to the pipe, they are closed — open them and then attempt a reset.

  3. Bleed your radiators to release trapped air DIY safe

    Starting on the ground floor and working upward, use a radiator bleed key to open each radiator bleed valve just until water (not air) emerges, then close it again. Check the system pressure afterwards and top up if it has dropped. This helps eliminate airlocks that may be preventing adequate circulation.

  4. Reset the boiler (up to 2–3 times only) DIY safe

    Once you have completed the checks above, press and hold the reset button on the boiler for 3–5 seconds, or follow the reset procedure in your user manual. Allow the boiler a few minutes to restart and attempt normal operation. If the F.24 code returns immediately or after a short time, stop resetting and move on — repeated resets without fixing the cause will not help and may mask a worsening problem.

  5. Listen and look for obvious pump problems DIY safe

    With the boiler running (if it restarts), listen near the pump location for grinding, rattling, or complete silence when the pump should be running. Also check for any obvious signs of a nearby water leak, which could indicate why pressure has been dropping. Note your findings to share with an engineer — do not attempt to open or dismantle the pump yourself.

  6. Call a Gas Safe registered engineer to diagnose and repair the fault Gas Safe engineer

    If the fault persists after the homeowner checks above, a Gas Safe registered engineer is needed. They will test pump operation and flow rates, check the diverter valve on combi models, inspect wiring and PCB connections, and carry out a system flush or powerflush if sludge is identified. Pump replacement, valve repair, and any work involving the boiler's internal components must only be carried out by a qualified engineer.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£400, depending on the underlying cause.

Frequently asked questions

Can I fix the Saunier Duval F.24 fault myself?

Some of the initial checks are perfectly safe for a homeowner — topping up system pressure via the filling loop, opening any closed isolation valves, bleeding radiators to remove airlocks, and resetting the boiler up to two or three times. However, if these steps do not clear the fault, the repair will almost certainly involve the pump, diverter valve, or internal wiring, all of which must be handled by a Gas Safe registered engineer. Attempting to dismantle or replace these components yourself is unsafe and could invalidate your boiler warranty.

How much does it typically cost to fix an F.24 fault in the UK?

For most UK homeowners, the repair falls between £150 and £400. A straightforward pump replacement — the most common fix — typically costs £150–£350 including parts and labour. If sludge is the root cause, a chemical flush for mild build-up runs around £100–£200, while a full powerflush (needed for heavily contaminated systems) costs roughly £350–£600 depending on the number of radiators. Adding a magnetic filter at the same time as a flush is advisable and typically adds £80–£150. In rare cases where a PCB fault is involved, costs can be higher — ask your engineer for a written quote before authorising any work.

Why does my F.24 fault keep coming back after resetting?

If the code clears after a reset but then returns within minutes, hours, or a few days, it means the underlying cause has not been resolved — the reset has simply allowed the boiler to attempt normal operation again. The most common reasons for recurring F.24 faults are a pump that is gradually seizing up, progressive sludge restriction, or a slow pressure leak that keeps bringing system pressure below the minimum threshold. Each reset without a fix adds wear to the boiler. Have a Gas Safe engineer investigate as soon as possible rather than continuing to reset.

Is the Saunier Duval F.24 the same as the Vaillant F.24?

Yes — Saunier Duval is part of the Vaillant Group and both brands use the same underlying control and fault-code system. An F.24 on either brand indicates a water circulation fault. The diagnostic approach and likely causes are identical, although the specific components may differ slightly between models. If you have a Vaillant engineer or a specialist familiar with either brand, they will recognise the fault immediately.

Affected models: Saunier Duval Themaclassic F24E, Saunier Duval Themaclassic Plus, Saunier Duval Themis, Saunier Duval Isofast, Saunier Duval Isotwin, Saunier Duval Thema, Saunier Duval Opalia

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F.24 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →