Saunier Duval F.26 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.26 fault code mean?

The F.26 fault code on a Saunier Duval boiler signals one of two distinct problems depending on your model. On most modern condensing boilers — including much of the Thema Condens range — F.26 points to a fault with the gas valve's stepper motor, meaning the PCB has detected an abnormal electrical signal from, or has lost communication with, the stepper motor that controls gas modulation. The boiler will typically lock out and refuse to ignite. On certain older Saunier Duval models (such as the Thema Condens F18 E SB), F.26 instead indicates that the temperature difference between the flow and return pipes has exceeded the permitted maximum — a sign that water is not circulating properly around the system. In both cases the boiler shuts down as a safety measure. Because Saunier Duval is part of the Vaillant Group and the two brands share engineering platforms, engineers familiar with Vaillant fault codes will recognise very similar root causes here.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your gas supply is working DIY safe

    Confirm the gas meter isolation valve is fully open and that other gas appliances in your home (hob, fire) are working normally. If you have no gas at all, contact your gas supplier rather than the boiler engineer.

  2. Top up boiler pressure if it is below 1 bar DIY safe

    Look at the pressure gauge — it should read between 1 and 1.5 bar when the heating is cold. If it is below 1 bar, use the filling loop (a small braided hose with one or two valves beneath the boiler) to add water until the gauge reads around 1.2 bar, then close the valve(s). Low pressure alone is unlikely to cause F.26 but a combined low-pressure and circulation issue can worsen the fault on some models.

  3. Attempt a boiler reset DIY safe

    Locate the reset button — usually marked with a flame symbol or the word 'Reset' on the front panel — and hold it for around three seconds. Allow the boiler a full minute to attempt a restart. If F.26 reappears immediately or returns within a short time, do not keep resetting repeatedly, as this will not fix an underlying fault and may mask important diagnostic information for the engineer.

  4. Note the exact model and when the fault first appeared DIY safe

    Find your boiler's model number (usually on a label inside the front panel or on the bottom casing) and make a note of any patterns — for example, does F.26 appear only on cold mornings, or immediately on every start attempt? This information helps the engineer narrow down whether the cause is stepper-motor-related or circulation-related before they even open the casing.

  5. Have a Gas Safe engineer inspect the wiring and connections to the gas valve and stepper motor Gas Safe engineer

    The engineer will remove the boiler casing and use a multimeter to check the electrical continuity and resistance of the stepper motor winding and the condition of all connectors between the PCB and the gas valve. Loose or corroded connectors are sometimes all that needs attention; re-seating them and resetting the boiler can restore normal operation at minimal cost.

  6. Have the gas valve and stepper motor tested and replaced if necessary Gas Safe engineer

    If the wiring checks out, the engineer will test the stepper motor and valve assembly directly. A valve that is mechanically seized or electrically open-circuit will need to be replaced. On Saunier Duval boilers the gas valve is a safety-critical component and must be sourced and fitted by a Gas Safe registered engineer. Note that Saunier Duval no longer trades in the UK, so confirm parts availability before committing to the repair.

  7. Have the circulation pump and system sludge levels assessed (if delta-temperature fault) Gas Safe engineer

    On models where F.26 flags a flow-to-return temperature problem, the engineer will check pump operation and may carry out a system chemical flush or power flush to remove magnetite sludge. Installing a magnetic filter at this stage helps prevent recurrence.

  8. Have the NTC thermistors tested if circulation appears normal Gas Safe engineer

    The engineer will measure the resistance of the flow and return NTC sensors at known temperatures and compare the readings against the manufacturer's specification. A drifted thermistor giving a false high or low reading is straightforward and relatively inexpensive to replace.

  9. Have the PCB assessed if all other components test satisfactory Gas Safe engineer

    If the gas valve, wiring, pump, and sensors all check out, the control board itself may be generating a spurious fault. PCB replacement is one of the more costly repairs; get a clear quote before proceeding and weigh this against the age of the boiler.

  10. Call a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    F.26 involves either a gas valve component or a safety-critical temperature fault — both require a Gas Safe registered engineer. You can find one at the Gas Safe Register website (gassaferegister.co.uk). Always ask to see their Gas Safe ID card before work begins.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£350, depending on the underlying cause.

Frequently asked questions

Is F.26 always a gas valve fault on Saunier Duval boilers?

Not always — it depends on the model. On most modern Saunier Duval condensing boilers the code relates to the gas valve's stepper motor, meaning the PCB has detected an abnormal electrical signal from the component that controls gas flow. On certain older models, however, F.26 indicates that the temperature difference between the flow and return pipes is too large, pointing instead to a circulation problem such as a failing pump or heavy sludge build-up. Check your model number and share it with the engineer so they can focus their diagnosis correctly from the start.

Can I reset a Saunier Duval F.26 fault myself?

You can attempt one or two resets using the reset button on the front panel, and occasionally a transient electrical glitch will clear after a reset. However, if F.26 returns immediately or comes back within a short time, further resetting will not help and may delay a proper fix. The underlying cause — whether a faulty stepper motor, loose wiring, or a circulation fault — will need a Gas Safe registered engineer to diagnose and repair.

How much does fixing a Saunier Duval F.26 fault typically cost in the UK?

Most people with this fault end up spending between £150 and £350. A gas valve or stepper motor replacement including labour typically falls in the £180–£300 range. If the problem turns out to be loose wiring or a faulty NTC thermistor, the cost can be lower. A full PCB replacement is a bigger outlay — often £350–£500 or more — but this is a less common outcome. Bear in mind that Saunier Duval no longer operates in the UK, so parts can sometimes be harder to source and prices may reflect that. If quotes are approaching or exceeding £500, it is worth comparing the repair cost against the price of a new boiler, especially on older units.

Can sludge cause F.26 on a Saunier Duval boiler?

Yes, on models where F.26 represents a flow-to-return temperature delta fault, sludge is a plausible culprit. Black iron oxide sludge reduces the rate at which water circulates around the system, causing the water returning to the boiler to be much cooler than the water leaving it. When this temperature gap exceeds the boiler's permitted limit, it logs F.26 and shuts down. A power flush or chemical system clean carried out by a heating engineer, ideally combined with fitting a magnetic filter to catch future sludge, can resolve this and prevent recurrence.

Affected models: Thema Condens, Thema Condens F18 E SB, Thema Condens F24 E, Isofast Condens, Isotwin Condens, Semia Condens

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F.26 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →