Saunier Duval F.20 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.20 fault code mean?

The F.20 code appears on most Saunier Duval boilers — including the Themaplus Condens, Thema Condens, Isomax, and ThemaClassic — when the water temperature inside the heat exchanger climbs past the manufacturer's safety limit of approximately 97°C. At that point, the boiler shuts itself down in a protective lockout to prevent component damage, dangerous pressure build-up, and any risk of scalding or explosion. The display will flash and alternate between two numbers (the second carrying a decimal point) to signal the fault type. Once the underlying cause has been addressed, pressing the Reset button restarts the boiler. Note: on the Condens range specifically, F.20 can occasionally point to a software incompatibility between components — often after an incorrect replacement part has been fitted — rather than a straightforward overheating event. Always cross-reference with your model's manual if the code reappears after a seemingly successful fix.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge DIY safe

    Look at the pressure gauge on the boiler front panel. It should read between 1.0 and 1.5 bar when the system is cold. A reading below 0.8 bar means there is insufficient water in the circuit, which can cause overheating.

  2. Top up system pressure via the filling loop if needed DIY safe

    Locate the filling loop — usually a short braided hose or a small tap beneath the boiler. Slowly open the valve(s) until the gauge reads approximately 1.2 bar, then close the valve fully. Never exceed 1.5 bar. If pressure drops again within a few days, there is likely a leak somewhere in the system.

  3. Bleed the radiators to remove trapped air DIY safe

    Starting with the radiator furthest from the boiler, use a bleed key to open the bleed valve at the top of each radiator until water (not air) starts to trickle out, then close it. Work back towards the boiler. Re-check the pressure gauge afterwards and top up if it has fallen below 1.0 bar.

  4. Reset the boiler DIY safe

    Once you have corrected the pressure and bled the radiators, press the Reset button and allow the boiler to restart. Observe it through at least one full heating cycle. If F.20 returns immediately or within a short time, do not keep resetting — repeated resets on an overheating fault can cause further component damage and should be avoided.

  5. Check whether the circulation pump is running DIY safe

    With the boiler running, place your hand carefully on the pipework near the pump — you should feel a slight vibration and the pipe should warm up as water flows. If the pump appears silent and the pipes stay cold, report this to your engineer. Do not attempt to open the pump or tamper with electrical connections yourself.

  6. Inspect for visible water leaks around the boiler DIY safe

    Look underneath and around the boiler casing for damp patches, drips, or white limescale staining that would indicate a slow leak. If you find one, turn off the boiler and contact a Gas Safe registered engineer — do not attempt to seal pipework joints or replace seals yourself.

  7. Call a Gas Safe registered engineer if F.20 returns or the cause is unclear Gas Safe engineer

    If the fault code reappears after your basic checks, or you could not identify an obvious cause, a Gas Safe registered engineer should carry out a full diagnostic. They can test the NTC temperature sensor with appropriate equipment, inspect and service or replace the circulation pump, perform a chemical flush or power flush to clear sludge and limescale from the heat exchanger and pipework, check and re-pressurise the expansion vessel diaphragm, and — on ThemaFast or Condens models — investigate any PCB communication issues. Only a Gas Safe registered engineer is legally permitted to carry out gas boiler component work in the UK.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£400, depending on the underlying cause.

Frequently asked questions

Can I just keep resetting the boiler when F.20 appears?

You can try one or two resets after correcting system pressure or bleeding radiators, but you should not repeatedly reset a boiler that keeps locking out on an overheating code. F.20 is a safety lockout designed to protect the heat exchanger and other components from damage caused by excessively high temperatures. Continually overriding it without fixing the root cause risks damaging the NTC sensor, the PCB, or the heat exchanger itself — repairs that can easily cost several hundred pounds. If the code returns within 48 hours of a reset, call a Gas Safe engineer.

How much does it typically cost to fix an F.20 fault in the UK?

Most homeowners pay somewhere between £120 and £400 to resolve an F.20 fault. A straightforward pump service or NTC sensor swap at the lower end, and a circulation pump replacement or expansion vessel job at the higher end, usually fall within that range. A power flush to clear sludge from the system typically costs £350–£500 on top of any component work. If the heat exchanger itself is found to be heavily scaled and needs replacing, costs can reach £600–£800 or more — at which point, on an older boiler, a new boiler installation may be worth considering.

Why does F.20 keep coming back a few days after I reset it?

An F.20 that clears on reset but reappears within a day or two — especially on the ThemaFast — often points to a faulty NTC temperature sensor giving intermittent false readings, or a communication fault between PCB boards rather than a genuine overheating event. On the Condens range, fitting an incompatible replacement part can also trigger this pattern. A Gas Safe engineer can test the sensor resistance with a multimeter and read live temperature data to confirm whether the boiler is truly overheating or whether the sensor is lying to the control board.

Could a water leak cause my Saunier Duval to show F.20?

Yes. A slow leak anywhere in the heating circuit — even a weeping joint behind a wall — gradually reduces system pressure. Once pressure falls low enough, there is insufficient water flowing through the heat exchanger and it overheats, triggering F.20. If your pressure gauge keeps dropping back below 1.0 bar despite regular top-ups, treat this as a strong indicator of a leak and have a Gas Safe engineer trace and repair it before the low pressure causes further damage.

Affected models: Themaplus Condens, Thema Condens, Isomax, ThemaClassic, ThemaFast, Condens

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer