Saunier Duval F13 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F13 fault code mean?

The F13 fault code on a Saunier Duval boiler points to a problem with the main control board (PCB). The boiler's internal diagnostics have detected either a failure of the board itself, a fault in its wiring connections, or a component that communicates with it — such as the domestic hot water storage tank sensor. When F13 appears the boiler will typically lock out completely and refuse to fire until the underlying issue is resolved. Because Saunier Duval and Glow-Worm share a platform within the Vaillant Group, the same code is sometimes described on shared models as a 'PCB main connections fault', highlighting that wiring and connector integrity is just as important to check as the board itself. Older Saunier Duval models may also show F13 when the relay that switches between central heating and domestic hot water modes has failed, so the exact cause can vary by model age and specification.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler using the reset button or by switching it off at the mains for 10–15 minutes DIY safe

    A sustained power-down (rather than a quick switch-off) allows the PCB's capacitors to fully discharge and the firmware to reinitialise. After restoring power, observe whether the boiler fires normally. If F13 does not return after one or two resets, a transient electrical glitch may have been the cause. Do not reset more than two or three times — repeated resets without a successful start indicate a genuine fault that needs investigation.

  2. Check that the boiler's mains electricity supply is stable and that no other sockets or circuits in the home are showing signs of power issues DIY safe

    A power surge or unstable voltage can damage the PCB. If you have experienced a power cut or electrical storm recently, note this when speaking to the engineer as it is diagnostically useful. If voltage instability is a recurring issue in your property, an engineer may recommend a surge-protection device on the boiler's supply.

  3. Do not attempt to open the boiler casing, inspect the PCB, or disturb any internal wiring Gas Safe engineer

    Checking and reseating PCB connectors, inspecting for burn marks, and testing wiring harnesses with a multimeter are diagnostic steps that must be carried out by a Gas Safe registered engineer. Interfering with internal wiring without the correct training can create unsafe conditions and will invalidate any remaining warranty.

  4. Contact a Gas Safe registered engineer to carry out a full electrical diagnosis Gas Safe engineer

    The engineer will power down the boiler safely, inspect all wiring looms and connector blocks for loose pins, corrosion, or damage, and test the PCB's input and output voltages with a multimeter. On models with a DHW storage tank they will also check the tank sensor's resistance reading. This systematic approach identifies whether the fault lies in wiring, a sensor, the relay, or the board itself — avoiding unnecessary parts replacement.

  5. Have the engineer replace the faulty component — PCB, sensor, relay, or wiring harness as identified Gas Safe engineer

    If the PCB itself has failed the engineer will source a compatible replacement board for your specific Saunier Duval model, fit it, and carry out a full commissioning check. If a DHW sensor or changeover relay is at fault, these are typically less costly to replace than the whole board. Once the repair is complete the engineer should reset and test all boiler functions including central heating and hot water modes.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£450, depending on the underlying cause.

Frequently asked questions

Can I fix an F13 fault myself on a Saunier Duval boiler?

The only safe DIY step is to attempt a full power-down reset. Everything beyond that — opening the casing, checking wiring, testing the PCB, or replacing any component — must be carried out by a Gas Safe registered engineer. Working on the internal electrics of a gas boiler without the correct qualifications is unsafe and illegal in the UK.

My F13 fault only appears when the boiler is in hot water mode — why?

This is a recognised pattern on Saunier Duval system boilers connected to a hot water cylinder. The most likely causes are a failing DHW tank sensor sending an erratic signal, or a worn changeover relay that struggles when it switches from heating to hot water mode. Tell your engineer exactly when the fault appears — it narrows the diagnosis significantly and can save time and money.

How much does it cost to fix a Saunier Duval F13 fault in the UK?

Most people pay between £120 and £450. A wiring or connector repair at the lower end can cost around £120–£200 including call-out. A sensor or relay swap typically falls in the £150–£280 range. A full PCB replacement — parts and labour — generally comes to £300–£500, though on some older or less common models where the board is hard to source, costs can be higher. Engineers in London and the South East tend to charge towards the top of these ranges.

Is it worth repairing an F13 fault or should I replace the boiler?

If your boiler is under ten years old and otherwise in good condition, repair is almost always worthwhile — especially if the fault turns out to be a sensor or wiring issue rather than the PCB itself. If the boiler is over twelve years old and a full PCB replacement is needed, it is worth getting a new boiler quote at the same time. As a rule of thumb, if the repair cost exceeds half the price of a comparable new boiler installation, replacement becomes the more sensible long-term investment.

Affected models: Saunier Duval Themaclassic, Saunier Duval Themis, Saunier Duval Isofast, Saunier Duval Isotwin, Saunier Duval Themaflex, Saunier Duval Gaz Solo (shared Glow-Worm platform variants)

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F13 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?