Ferroli F20 Fault Code: Causes, Fixes & Repair Costs

What does the Ferroli F20 fault code mean?

The F20 fault code appears on certain Ferroli boiler models — most notably the Domiproject D/F range and the DOMIcondens HE 26C — and indicates that the boiler has detected a problem with combustion quality or combustion control. In plain terms, the boiler has sensed that the burner is not burning gas in the way it should, so it has shut down as a precaution. Because F20 begins with 'F', Ferroli classifies it as a blocking fault rather than a full lockout: it may clear on its own if the underlying condition resolves, but if it keeps returning you need a Gas Safe engineer to investigate. Do not confuse this with A-series codes (such as A01 or A02), which are hard lockouts always requiring a manual reset. Important note: Ferroli fault code meanings can differ between model ranges (Modena, Bluehelix, Optimax, i-Series, Domiproject). Always cross-reference your boiler's own user manual to confirm the exact meaning for your unit.

Engineer may be needed May need a Gas Safe engineer 3 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check whether other gas appliances in your home are working DIY safe

    Turn on a gas hob ring or check another gas appliance. If nothing is working, your gas supply has been interrupted — contact your gas supplier (e.g. Cadent, SGN) rather than a boiler engineer. If the hob lights normally, the gas supply is fine and the issue is with the boiler itself.

  2. Inspect the external flue terminal for visible blockages DIY safe

    From ground level, look at the flue outlet on the outside wall. Check for obvious obstructions such as leaves, a bird's nest, ice, or anything pressed against the terminal. Do not climb ladders or attempt to remove the flue yourself — if you spot a blockage you cannot safely clear from the ground, report it to your engineer.

  3. Check for a frozen condensate pipe in cold weather DIY safe

    In freezing temperatures, the plastic condensate pipe that runs outside (or through an unheated space) can ice up and cause the boiler to fault. You can safely thaw it by pouring warm — not boiling — water over the pipe or wrapping it in a warm cloth. Once thawed, attempt a reset. Consider lagging the pipe to prevent a repeat.

  4. Reset the boiler once DIY safe

    Press and hold the reset button (usually marked with an 'R' or a flame symbol) for around 5–10 seconds, then release. Allow the boiler a full minute to attempt a restart. If it fires up and runs normally, monitor it closely over the next few hours. If F20 returns, do not reset again — repeated resets on a combustion fault risk damaging the heat exchanger and fan.

  5. Check and restore boiler system pressure if low DIY safe

    Look at the pressure gauge on the boiler. It should read between 1.0 and 1.5 bar when cold (check your manual for the exact recommended range). If pressure is below 0.8 bar, top it up using the filling loop — a pair of small valves under the boiler connected by a braided hose. Open both valves slowly, watch the gauge, and close them once pressure reaches around 1.2 bar. Dry and replace the loop afterwards.

  6. Call a Gas Safe registered engineer if F20 persists or returns Gas Safe engineer

    If the fault code comes back after a single reset, or if none of the above steps resolve it, you need a qualified Gas Safe engineer. They will inspect and test the ionisation and ignition electrodes, verify gas inlet pressure and valve operation, check fan speed and airflow, examine the PCB for communication faults, and clear any internal condensate trap blockage. Do not continue resetting the boiler in the hope it clears — on a combustion fault this can cause costly secondary damage.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£350, depending on the underlying cause.

Frequently asked questions

Is the Ferroli F20 a lockout or a blocking fault?

F20 is a blocking fault, not a lockout. Ferroli uses codes starting with 'A' for hard lockouts that always need a manual reset. F-series codes like F20 may clear automatically if the root cause resolves itself — for example, a frozen condensate pipe that thaws out. However, if F20 keeps reappearing, it will not fix itself and you should book a Gas Safe engineer.

Can I keep resetting my Ferroli boiler to clear F20?

You should attempt no more than one or two resets. F20 is triggered by a combustion quality problem, and forcing the boiler to attempt firing repeatedly without fixing the cause can overheat the heat exchanger and burn out the fan — both expensive components to replace. If the fault returns after a single reset, leave the boiler off and call a Gas Safe engineer.

Does F20 mean the same thing on all Ferroli boilers?

Not exactly. F20 is specifically documented as a combustion quality fault on the Domiproject D and F models, and as a combustion control fault on the DOMIcondens HE 26C. Other Ferroli ranges such as the Modena, Bluehelix, and Optimax may use different codes to describe similar faults, or may not use F20 at all. Always check your model's user manual or ask a Gas Safe engineer to confirm the exact meaning for your boiler.

How much does it cost to fix a Ferroli F20 fault in the UK?

Most people pay somewhere between £120 and £350 all-in, depending on what the engineer finds. A diagnostic visit to clean the electrodes and clear a flue or condensate blockage typically costs £120–£180. Fan replacement usually runs £180–£250 including parts and labour, and a gas valve swap tends to be £250–£350. A PCB replacement can cost more — the board alone can be £180 or above on some Domiproject models, with fitting on top of that — so if the control board has failed on an older Ferroli, it is worth getting a like-for-like replacement quote alongside a new boiler quote before committing.

Affected models: Ferroli Domiproject D, Ferroli Domiproject F, Ferroli DOMIcondens HE 26C

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ferroli F20 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →