The F85 code appears on your Glow Worm boiler when the PCB (printed circuit board) has detected a problem with one or both of the NTC thermistors — the temperature sensors fitted to the flow and return heating pipes. The flow thermistor sits on the pipe carrying hot water out of the boiler, while the return thermistor monitors water coming back in after circulating around the heating system. These sensors continuously send resistance readings to the PCB, which uses them to control heat output. When a reading falls outside the expected range — due to a failed sensor, a wiring fault, or in rarer cases a PCB issue — the boiler locks out and displays F85 to prevent unsafe operation. A simple reset is unlikely to clear this fault permanently; the underlying sensor or wiring problem needs to be diagnosed and resolved by a Gas Safe registered engineer.