Saunier Duval F.85 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.85 fault code mean?

The F.85 code indicates that the boiler's PCB has detected a persistent, abnormal temperature difference between the flow and return NTC thermistors — the two sensors that monitor water temperature as it leaves and re-enters the boiler. This could mean the sensors are fitted to the wrong pipes, are reading incorrect resistance values, have wiring faults, or that heat transfer through the heat exchanger is poor. Because Saunier Duval is part of the Vaillant Group, the F.85 carries the same meaning across Saunier Duval and Vaillant boilers. The boiler will lock out and must be investigated by a Gas Safe registered engineer before normal operation can resume.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the boiler display and note the fault code DIY safe

    On most Saunier Duval models the display alternates between two numbers — the second has a decimal point after it — to indicate a fault. Confirm you are seeing F.85 so a correct diagnosis can be given when you contact an engineer.

  2. Attempt a single boiler reset DIY safe

    Press and hold the reset button as described in your boiler's user guide. If the boiler restarts and runs normally, monitor it closely. If F.85 returns promptly or the boiler locks out again within a short time, do not keep resetting — repeated resets can mask a genuine fault and may cause further damage.

  3. Check that your gas supply is working DIY safe

    Confirm other gas appliances in your home (e.g. a gas hob) are working normally. If there is no gas supply to any appliance, contact your gas supplier rather than an engineer.

  4. Do not attempt to access or move the temperature sensors Gas Safe engineer

    The NTC thermistors are internal components attached to the boiler's pipework and wiring loom. Repositioning, disconnecting, or replacing them requires a Gas Safe registered engineer and should never be attempted by a homeowner.

  5. Do not interfere with the wiring or PCB Gas Safe engineer

    Inspecting or repairing the wiring loom or PCB inside the boiler is not homeowner-safe work. Incorrect handling can create new faults, invalidate your warranty, and pose an electrical hazard.

  6. Have a Gas Safe engineer test the thermistors with a multimeter Gas Safe engineer

    The engineer will disconnect each NTC thermistor and measure its resistance (expected ~12 kΩ at 20°C). A reading significantly above or below this indicates a faulty sensor. They will also check that each sensor is clamped to the correct pipe.

  7. Have the engineer inspect the wiring loom and connections Gas Safe engineer

    All wiring between the thermistors and the PCB should be checked for continuity, correct terminal seating, and any signs of heat damage or corrosion. Faulty sections of wire or terminals will be repaired or replaced.

  8. Have the engineer assess heat exchanger performance and gas rate Gas Safe engineer

    If sensors and wiring are healthy, the engineer should verify the gas input rate and check whether heat exchanger scaling or blockage is causing a persistently low temperature differential.

  9. Have the PCB tested if all other components are satisfactory Gas Safe engineer

    Only once sensors, wiring, and heat exchanger performance have been ruled out should the PCB be investigated. A competent engineer will test the PCB's signal inputs and outputs rather than replacing it on assumption.

  10. Call a Gas Safe registered engineer Gas Safe engineer

    F.85 is not a fault that can be resolved by homeowner action beyond a single reset attempt. Contact a Gas Safe registered engineer — check the register at gassaferegister.co.uk — and describe the F.85 code. Always ask for a written quote and confirm whether the call-out fee is included.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£350, depending on the underlying cause.

Frequently asked questions

Can I fix the Saunier Duval F.85 fault myself?

No. While you can safely attempt one reset and check that your gas supply is on, the underlying cause of F.85 — whether it is a mispositioned sensor, a faulty thermistor, damaged wiring, or a PCB issue — requires a Gas Safe registered engineer to diagnose and repair. Attempting to access internal components yourself is unsafe and will likely void any remaining warranty.

How much does it cost to fix an F.85 fault on a Saunier Duval boiler?

Most homeowners pay between £150 and £350 to resolve an F.85 fault. Replacing one or both NTC thermistors, including parts and labour, typically falls in the £150–£200 range. If wiring repairs are also needed the cost rises toward the upper end of that range. In the less common scenario where the PCB needs replacing, costs can exceed £400 — but a good engineer will always rule out cheaper causes first before recommending a PCB replacement.

Why does the Saunier Duval F.85 code look the same as the Vaillant F.85?

Saunier Duval is owned by the Vaillant Group and shares the same underlying boiler technology and fault code architecture as Vaillant and Glow-worm. The F.85 code means the same thing across all three brands: a persistent, abnormal difference detected between the flow and return temperature sensor readings.

Will my boiler work at all when F.85 is showing?

No. F.85 is a lockout fault, which means the boiler shuts itself down completely and will not provide heating or hot water until the fault is cleared. This is a safety feature — running the boiler with unreliable temperature data could allow dangerously high temperatures to develop undetected. You may get a brief restart after pressing reset, but the boiler will lock out again if the root cause has not been fixed.

Affected models: Saunier Duval Thema, Saunier Duval Themaplus, Saunier Duval Isofast, Saunier Duval Isotwin, Saunier Duval Themafast, Saunier Duval Themis

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F.85 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →