Saunier Duval F.73 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.73 fault code mean?

The F.73 code appears when the boiler's water pressure sensor sends a signal that falls outside the expected range, or when the sensor connection to the control board is interrupted or short-circuited. In plain terms, the boiler can no longer trust the reading it's getting from the pressure sensor — so it shuts down as a precaution. You'll typically see the F.73 code flashing on the display, with no heating or hot water available, and the fault may return immediately after a reset if the underlying cause hasn't been addressed. Saunier Duval boilers are part of the Vaillant Group, and this fault code carries the same meaning across compatible models in both ranges.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler DIY safe

    Press and hold the reset button as described in your boiler's user guide. If the F.73 code clears and the boiler fires up normally, monitor it over the next few hours. If the fault returns promptly after reset, move on to the next checks rather than repeatedly resetting — more than two or three resets without success won't help and could mask the problem.

  2. Check the system pressure gauge DIY safe

    Look at the pressure gauge on the boiler (or your heating system). For a Saunier Duval boiler at rest (cold), the pressure should sit between 1.0 and 1.5 bar. If it reads below 0.8 bar, the system needs topping up. Locate the filling loop — usually a silver braided hose with a small valve beneath the boiler — and slowly open the valve until the gauge rises to around 1.2–1.5 bar, then close it firmly. Do not exceed 2 bar.

  3. Bleed the radiators if pressure drops repeatedly DIY safe

    If you find yourself needing to top up pressure regularly, trapped air may be escaping and pulling pressure down. Turn the heating off and allow it to cool. Using a radiator bleed key or flat-head screwdriver, open each radiator's bleed valve (starting with the lowest floor) just enough to let air hiss out, then close it once water appears. Re-check and top up system pressure afterwards if needed.

  4. Look for signs of a water leak DIY safe

    With the boiler casing on (do not remove it), check the area around and beneath the boiler for drips, damp patches, or white limescale staining on pipework. Also check nearby radiator valves and any visible pipework. If you spot a leak, do not attempt to fix it yourself — note its location and report it to a Gas Safe engineer.

  5. Gas Safe engineer: inspect and reseat the sensor wiring Gas Safe engineer

    With the boiler isolated from power, the engineer will trace the cable running from the pressure sensor to the PCB, checking for chafing, pinching, burnt insulation, or a damaged sheath. A multimeter in resistance mode will confirm whether continuity is intact. If the connector has worked loose or moisture is present, reseating or cleaning the plug often clears the fault without any parts being replaced.

  6. Gas Safe engineer: test and replace the pressure sensor if required Gas Safe engineer

    The engineer will disconnect the sensor connector and measure the resistance across its pins, comparing the result against the specification for your specific model. A zero-ohm reading indicates an internal short; an infinite reading indicates an open circuit. In either case — or if scale or debris has blocked the sensor port — the component needs replacing. The Saunier Duval pressure sensor (part no. S5720500) typically costs £15–£30 in parts, with total labour and parts usually coming in at £80–£200.

  7. Gas Safe engineer: replace the PCB if all else checks out Gas Safe engineer

    If the sensor and wiring are confirmed to be functioning correctly but F.73 persists, the PCB is the remaining suspect. PCB replacement is a last-resort diagnosis and carries a higher cost — typically £180–£400 depending on the model. An experienced engineer will want to be confident the board is genuinely at fault before committing to this repair, particularly on an older boiler where the cost-versus-replacement calculation matters.

  8. Call a Gas Safe registered engineer if you haven't already Gas Safe engineer

    If the homeowner checks above haven't resolved the fault, or if you've found a leak or suspect an electrical issue, contact a Gas Safe registered engineer. You can verify any engineer's registration at gassaferegister.co.uk. Attempting to work on the internal components of a gas boiler without Gas Safe registration is illegal in the UK and potentially dangerous.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£250, depending on the underlying cause.

Frequently asked questions

Can I fix the Saunier Duval F.73 fault myself?

Only to a limited extent. As a homeowner you can safely reset the boiler, check and top up the system pressure via the filling loop, bleed the radiators, and look for obvious leaks. However, inspecting or replacing the pressure sensor, checking wiring, or touching any internal electrical components must be carried out by a Gas Safe registered engineer. Working on a gas appliance without registration is illegal in the UK.

How much does it cost to fix a Saunier Duval F.73 fault?

Most F.73 repairs fall in the £80–£200 range, covering a call-out, sensor inspection, and — if needed — a replacement pressure sensor. Interestingly, more than 60% of cases are resolved simply by reseating a loose connector or drying out moisture, so you may not need a new part at all. If the PCB turns out to be the root cause, costs typically rise to £180–£400 depending on the model. On an older boiler, it's worth getting a boiler health check at the same time to weigh up repair versus replacement.

Why does my boiler keep showing F.73 even after I reset it?

If F.73 returns immediately or within a short time after a reset, a simple power-cycle is unlikely to be the solution — the underlying fault is still present. This pattern usually points to a failed pressure sensor sending a consistently out-of-range signal, a persistently loose or corroded connector, or moisture in the wiring. Repeated resets won't cause harm but won't fix it either; you need a Gas Safe engineer to diagnose the root cause.

Is the Saunier Duval F.73 the same fault as Vaillant F.73?

Yes. Saunier Duval is part of the Vaillant Group, and the two brands share the same fault-code definitions across their condensing boiler ranges. F.73 on a Vaillant boiler means exactly the same thing — a water pressure sensor signal that is out of range, short-circuited, or disconnected — and the diagnostic and repair process is essentially identical.

Affected models: Semia Condens, Themaplus Condens, Isotwin Condens, Themafast Condens, Isomax Condens

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F.73 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →