Saunier Duval F.67 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.67 fault code mean?

The F.67 fault code appears on Saunier Duval boilers when the main PCB (printed circuit board) is not receiving a valid flame signal during or after the ignition sequence. In straightforward terms, the boiler attempts to light, but its control board either sees no flame signal at all, or the signal it receives is too weak or erratic to confirm a stable flame is present. As a safety response, the boiler locks out to prevent unburned gas from building up. Saunier Duval shares its boiler platform and fault-code architecture with Vaillant (both are part of the same group), so F.67 carries an identical meaning on Vaillant appliances. The most common culprits are a faulty ionisation (flame-sensing) electrode and PCB-related issues such as loose connections, water ingress, or a damaged board. A professional diagnosis is always needed because the fault sits squarely within the electrical and gas-detection side of the appliance.

Lockout — engineer likely May need a Gas Safe engineer 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the boiler's gas supply is live DIY safe

    Before anything else, confirm that the gas isolation valve on the supply pipe to the boiler is fully open (handle parallel to the pipe). Check that other gas appliances in the property — hob, cooker, gas fire — are working normally. If there is no gas at other appliances, contact your gas supplier rather than a boiler engineer.

  2. Attempt a single reset DIY safe

    Press and hold the reset button on the boiler's control panel as described in your user manual (typically 3–5 seconds). Allow the boiler a full minute to attempt re-ignition. If the F.67 code reappears promptly, do not keep resetting repeatedly — doing so without resolving the root cause will not help and can mask useful diagnostic information. Limit yourself to two or three resets at most.

  3. Engineer: inspect and test the ionisation electrode and its cable Gas Safe engineer

    A Gas Safe engineer will remove the boiler casing and access the burner assembly. They will visually inspect the electrode for cracks in the ceramic insulator, check the rod for heavy oxidation or soot deposits, and test the connecting cable for continuity and insulation integrity. A lightly soiled electrode may be cleaned with fine abrasive; a cracked or failed one must be replaced with the correct Saunier Duval part.

  4. Engineer: check all PCB wiring connectors and grounding Gas Safe engineer

    The engineer will reseat all relevant plug connectors at the PCB, paying particular attention to the flame-detection circuit. They will also verify that the electrode's ground path back to the burner chassis is intact — poor grounding can prevent a valid ionisation current even when the electrode itself is in good condition.

  5. Engineer: inspect for internal water leaks before touching the PCB Gas Safe engineer

    Before any PCB assessment, the engineer should check around the heat exchanger, pump, and pipework joints for signs of moisture or dried limescale deposits that indicate a previous leak. Any active leak must be repaired first; fitting a new PCB into a leaking boiler risks immediate repeat damage.

  6. Engineer: test and replace the PCB if required Gas Safe engineer

    If the electrode, cabling, and connections all test satisfactory, the engineer will assess the PCB itself — checking for visible damage such as burned tracks or cracked solder joints. If the flame-detection circuit has failed, the board will need to be replaced with a compatible Saunier Duval PCB. This is a specialist task requiring the correct part and post-installation testing of all safety functions.

  7. Call a Gas Safe registered engineer if the fault persists or you are unsure Gas Safe engineer

    F.67 is not a fault that resolves itself or one that a homeowner can safely work on. If the reset has not cleared it, or it returns after clearing, book a Gas Safe registered engineer as soon as possible. You can verify an engineer's registration at gassaferegister.co.uk. Continuing to use a boiler that is locking out on a flame-detection fault is not safe.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£400, depending on the underlying cause.

Frequently asked questions

Can I fix the Saunier Duval F.67 myself?

Not safely, no. The F.67 fault involves the boiler's flame-detection circuitry and requires access to the internal components of a gas appliance. In the UK, working inside a boiler is legally restricted to Gas Safe registered engineers. What you can safely do is check that the gas supply is on and try resetting the boiler once or twice. If the fault persists, you need to call a qualified engineer.

Will replacing the PCB definitely fix F.67?

Not necessarily — and that is exactly why a proper diagnosis matters. The PCB is one possible cause, but a faulty ionisation electrode or a simple loose connector is statistically more likely and far cheaper to fix. A good engineer will work through the electrode, cabling, and connections before recommending a board replacement. If the PCB does turn out to be the problem, expect to pay in the region of £300–£550 including labour. On a boiler older than ten years, it is worth comparing that cost against a new boiler installation before committing.

How long does it take to repair an F.67 fault?

If the problem is a dirty or failed electrode or a loose connection, an engineer can usually diagnose and resolve it within an hour or two on the same visit, provided they carry common parts. A PCB replacement takes longer — typically two to three hours — and may require the engineer to order the specific board if they do not have one on the van, which can mean a return visit.

Why does F.67 keep coming back after I reset the boiler?

A reset simply clears the fault flag and lets the boiler attempt ignition again; it does nothing to address the underlying problem. If F.67 returns each time, it means the root cause — most likely a degraded ionisation electrode, a damaged PCB connection, or water damage to the board — is still present. Repeated resets without a repair can also mask diagnostic patterns that help an engineer pinpoint the fault quickly, so it is best to stop resetting and book an engineer promptly.

Affected models: Saunier Duval Thema, Saunier Duval Themaclassic, Saunier Duval Themis, Saunier Duval Isofast, Saunier Duval Isotwin, Saunier Duval Gaz Solo, Saunier Duval Opalia, Saunier Duval Combitek

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F.67 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →