Saunier Duval F.63 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.63 fault code mean?

The F.63 fault code points to an electronic failure within the boiler's main printed circuit board (PCB), specifically involving the EEPROM — a small memory chip that stores the board's operating data. When this chip malfunctions or loses communication with other electronic components, the boiler detects an internal data or signalling error and shuts down as a precaution. Because the PCB is responsible for coordinating every major component — the pump, gas valve, sensors, and ignition — even a partial failure here can bring the whole boiler to a standstill. Saunier Duval is part of the Vaillant Group and shares its electronics platform with Vaillant and Glow-worm boilers, so F.63 carries the same meaning across all three brands. It is also worth noting that F.61, F.62, F.63, and F.64 codes can sometimes appear interchangeably on the same boiler; they often share a root cause, so diagnosing one thoroughly can resolve others.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Stop resetting the boiler repeatedly DIY safe

    A single reset is reasonable to attempt, but pressing the reset button again and again after an F.63 is not recommended. Repeated resets can mask the underlying fault, stress other components, and in some circumstances create safety risks. If the fault returns after one reset, leave the boiler off and move to the next step.

  2. Check that your gas supply is working DIY safe

    Before calling an engineer, confirm that other gas appliances in your home — a gas hob, for example — are working normally. If nothing gas-powered is functioning, the issue may be with your gas supply rather than the boiler. Contact your gas supplier if you suspect a supply interruption.

  3. Arrange a visit from a Gas Safe registered engineer for diagnosis Gas Safe engineer

    Because F.63 is rooted in the boiler's electronics and gas valve circuit, all further investigation must be carried out by a qualified Gas Safe engineer. They will use a multimeter to check resistance values across the gas valve coils, inspect PCB connections, and assess whether the EEPROM fault is isolated to the board or linked to a downstream component.

  4. Engineer to test the gas valve resistance Gas Safe engineer

    The engineer will measure the resistance across the gas valve's coils and compare the reading against the manufacturer's specification. A reading outside tolerance confirms the valve is faulty. If the valve tests correctly, attention turns to the PCB itself.

  5. Engineer to inspect all wiring and connector blocks Gas Safe engineer

    The engineer should check every connector leading to and from the PCB — particularly those serving the gas valve, pump, and temperature sensors — using a multimeter to identify any open circuits, high-resistance joints, or signs of corrosion. Re-seating loose connectors sometimes resolves F.63 without the need for a part replacement.

  6. Replace the faulty component (PCB or gas valve) Gas Safe engineer

    Once the diagnosis is clear, the engineer will replace the defective part. If a new PCB is fitted, it will need to be correctly configured for your specific boiler model before the appliance is restarted — skipping this step can cause the fault to reappear immediately. If both the gas valve and PCB are suspect, the engineer may recommend replacing both to avoid a repeat call-out.

  7. Consider whether repair or boiler replacement makes better financial sense DIY safe

    If your Saunier Duval boiler is 12 years old or more, or if the engineer identifies that several components are worn alongside the PCB, it may be worth getting a new boiler quote alongside the repair quote. PCB replacement is one of the more expensive single repairs on a boiler, so putting that money towards a new, efficient appliance can be the better long-term decision.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £250–£500, depending on the underlying cause.

Frequently asked questions

Is F.63 on a Saunier Duval always a PCB fault?

Not always, although the PCB is the most common cause. The F.63 code flags an EEPROM or electronic communication error, which usually originates on the main board — but a faulty gas valve, corroded wiring, or a misconfigured replacement PCB can produce exactly the same code. A Gas Safe engineer needs to work through the diagnosis systematically rather than automatically ordering a new PCB. In some cases a loose connector is the only issue and the repair cost is minimal.

Can F.63 appear alongside F.61, F.62, or F.64 on the same boiler?

Yes. On Saunier Duval (and the related Vaillant and Glow-worm ranges) these codes sit in the same electronic fault family. A single underlying problem — such as a deteriorating PCB or a failing gas valve — can cause the boiler to cycle through different codes on different occasions. If you have seen more than one of these codes on your boiler, tell the engineer when you call; it helps them build a clearer picture before they arrive.

How much does it cost to fix an F.63 fault in the UK?

Most homeowners pay somewhere between £250 and £500 all-in, depending on which component needs replacing. A gas valve swap typically costs around £200–£320 including parts and labour, while a PCB replacement tends to sit in the £320–£450 range. In straightforward cases where only a wiring connector needs re-seating the bill will be considerably lower — largely a call-out and labour charge. If the engineer finds that both the PCB and gas valve need replacing, costs can push above £600, at which point a new boiler quote is worth having for comparison.

Is it safe to keep using the boiler while it shows F.63?

No. F.63 is a lockout fault, which means the boiler has already shut itself down as a safety measure. You should not attempt to keep forcing it back on with repeated resets. Leave the boiler off, ensure your home stays warm through other means if needed, and contact a Gas Safe registered engineer promptly. Repeatedly overriding a lockout can put additional strain on components and, depending on the root cause, could create a safety risk.

Affected models: Saunier Duval Thelia, Saunier Duval Themafast, Saunier Duval Themis, Saunier Duval Isofast, Saunier Duval Isotwin, Saunier Duval Sdmo

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F.63 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →