Saunier Duval F.61 Fault Code: Causes, Fixes & Repair Costs

What does the Saunier Duval F.61 fault code mean?

The F.61 fault code signals that the boiler's PCB (printed circuit board) has detected a problem controlling or communicating with the gas valve. The gas valve is responsible for regulating gas flow to the burner, and if the PCB cannot send a reliable command to the valve — or cannot confirm the valve is responding correctly — the boiler shuts down as a safety precaution. This is a lockout fault, meaning the boiler will not attempt to fire again until the underlying issue is resolved and the unit is manually reset. Saunier Duval is part of the Vaillant Group, so the F.61 code also appears on some Vaillant ecoTEC and Glow-worm models with broadly the same meaning. On most displays, the fault code flashes and two characters alternate — the second number typically has a decimal point after it to distinguish it from other codes.

Lockout — engineer likely May need a Gas Safe engineer 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your gas supply is working DIY safe

    Confirm that other gas appliances in your home (such as a hob or gas fire) are working normally. If nothing gas-powered is working, contact your gas supplier, as there may be a supply interruption. Do not attempt to investigate the gas meter or pipework yourself.

  2. Attempt a boiler reset DIY safe

    Locate the reset button on the boiler's fascia (refer to your user manual if needed) and hold it for the duration specified — usually around 3 seconds. Allow the boiler a couple of minutes to attempt a restart. If it fires up and runs normally, monitor it closely over the next few hours. Do not reset the boiler more than two or three times in total, as repeated lockouts without a fix can indicate a more serious underlying problem.

  3. Call a Gas Safe registered engineer to inspect the gas valve Gas Safe engineer

    An engineer will test whether the gas valve is opening and closing correctly in response to signals from the PCB. A valve that is seized or has failed electrically will need to be replaced — this is not a DIY repair and must be carried out by a qualified professional, as it involves direct work on the gas circuit.

  4. Have the wiring and connections between the PCB and gas valve inspected Gas Safe engineer

    The engineer will check the wiring harness and terminal connections for signs of corrosion, looseness, or damage. If a simple connection issue is found, it can often be rectified quickly. If the harness itself is damaged, a replacement will be fitted.

  5. Have the PCB tested and replaced if necessary Gas Safe engineer

    If the gas valve and wiring are both found to be in good order, the PCB becomes the primary suspect. The engineer will test the board's output signals and, if a fault is confirmed, replace the PCB. For older boilers, it is worth asking the engineer whether the cost of a new PCB represents good value given the age and overall condition of the appliance.

  6. Ask the engineer to verify gas supply pressure and carry out a full system check Gas Safe engineer

    A thorough engineer will also confirm that gas pressure at the boiler is within the manufacturer's specified range, and will inspect related components such as the ignition electrode and ignition lead, which can occasionally contribute to this fault code.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£380, depending on the underlying cause.

Frequently asked questions

Can I fix an F.61 fault myself?

Your safe options as a homeowner are limited to checking that your gas supply is on and attempting one or two resets of the boiler. Any work beyond that — testing or replacing the gas valve, PCB, or wiring — must be carried out by a Gas Safe registered engineer. Working on gas components without the correct registration is illegal in the UK and potentially very dangerous.

How much does it cost to fix an F.61 fault code on a Saunier Duval boiler?

Most people with an F.61 fault end up paying somewhere between £150 and £380, depending on what needs replacing. A wiring or connection fix at the lower end, or a gas valve replacement in the mid-range, accounts for the majority of repairs. If the PCB turns out to be the faulty component, costs can rise further — a new PCB including labour can reach £400–£500 or more. On older boilers (over 10–12 years), it is worth comparing repair costs against the price of a new, more efficient appliance.

Why does the F.61 code also appear on Vaillant and Glow-worm boilers?

Saunier Duval is owned by the Vaillant Group, which means several of its boiler ranges share the same underlying control systems and fault-code definitions. The F.61 gas valve control error appears on Vaillant ecoTEC and certain Glow-worm models for the same reason — a PCB-to-gas-valve communication problem. The diagnostic approach and typical repairs are very similar across all three brands.

My boiler keeps showing F.61 after resetting — what does that mean?

If F.61 returns quickly after each reset, it strongly suggests there is a genuine component fault rather than a one-off glitch. Repeated lockouts are a sign that the boiler's safety systems are doing their job — the boiler is refusing to fire because it cannot confirm safe gas valve operation. Stop resetting and call a Gas Safe engineer to carry out a proper diagnosis, as continued resets without a fix will not resolve the underlying problem.

Affected models: Saunier Duval Thema, Saunier Duval Themaclassic, Saunier Duval Themis, Saunier Duval Isofast, Saunier Duval Isotwin, Saunier Duval Exacontrol, Vaillant ecoTEC (Vaillant Group shared code), Glow-worm (Vaillant Group shared code)

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Saunier Duval F.61 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →