GWGlow-worm logo

Glow-worm F61 Fault Code: Causes, Fixes & Repair Costs

What does the Glow-worm F61 fault code mean?

The F61 code appears when your Glow-Worm boiler detects a problem with the gas valve control system. In practice this sits at the crossroads of two related faults: the boiler's PCB (printed circuit board) is responsible for sending precise electrical signals to open and close the gas valve, so a failure in either the PCB's output circuitry or in the gas valve itself can trigger this code. Glow-Worm's own classification groups F61 through F68 as main board faults, with F61 specifically flagging the gas valve control pathway. The boiler will lock out and refuse to fire until the root cause is identified and resolved. Because both gas components and the control board are involved, this fault always requires attention from a Gas Safe registered engineer — it is not safe or appropriate for a homeowner to attempt repairs beyond a single reset.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Attempt a single boiler reset DIY safe

    Locate the reset button on your Glow-Worm boiler's control panel — on most models this is a clearly marked button you hold for approximately one second. Allow the boiler a minute or two to run through its ignition sequence. If the boiler fires and runs normally, monitor it over the next few hours. If F61 returns, do not keep resetting: repeated lockouts on this code indicate a genuine component fault that resetting will not fix.

  2. Check your gas supply is working DIY safe

    Confirm that other gas appliances in your home — a gas hob, for example — are working normally. If they are not, there may be a wider gas supply issue; contact your gas supplier or call the National Gas Emergency Service on 0800 111 999. If other appliances are fine, the issue is internal to the boiler.

  3. Do not attempt any further DIY investigation Gas Safe engineer

    F61 involves the gas valve control circuit and potentially the PCB — both of which are outside the scope of homeowner intervention. Do not open the boiler casing, disconnect any wiring, or attempt to inspect or clean the gas valve. Doing so could be dangerous and will likely invalidate any remaining warranty.

  4. Book a Gas Safe registered engineer for diagnosis Gas Safe engineer

    A qualified engineer will use a multimeter and boiler-specific diagnostic tools to test voltage and continuity across the PCB's gas valve output, the solenoid coils on the valve itself, and the wiring harness between them. This pinpoints whether the fault lies with the board, the valve, or the connecting wiring, and avoids unnecessary part replacement.

  5. PCB repair or replacement (engineer only) Gas Safe engineer

    If the PCB is at fault, the engineer will assess whether the damage is minor enough to repair on-site — for example, a re-soldered joint — or whether a full board replacement is required. Given the cost of labour versus a damaged board, full replacement is more common. Ensure the replacement board is the correct part number for your specific Glow-Worm model.

  6. Gas valve replacement if required (engineer only) Gas Safe engineer

    If testing confirms the gas valve solenoid has failed or the valve is mechanically seized, the engineer will replace it with an approved part. Gas valve work is a Gas Safe legal requirement — under no circumstances should this be attempted by anyone without current Gas Safe registration.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £220–£500, depending on the underlying cause.

Frequently asked questions

Can I fix a Glow-Worm F61 fault myself?

No. F61 involves the gas valve control circuit — and potentially the PCB — both of which require a Gas Safe registered engineer. A homeowner can safely try one reset and check that their gas supply is working, but that is the limit of safe DIY involvement. Opening the boiler casing or touching gas components without Gas Safe registration is illegal and dangerous.

How much does it cost to fix a Glow-Worm F61 fault in the UK?

Most people with an F61 fault pay somewhere between £220 and £500 all-in, depending on whether the root cause is a wiring fault, a gas valve replacement (typically £200–£350 including labour), or a PCB replacement (typically £300–£500 including labour and parts). Engineers may also charge a diagnostic fee of £60–£100 before committing to a repair. In rare cases where both the PCB and gas valve have failed simultaneously, costs can exceed £600 — at that point, if the boiler is over 10 years old, a full replacement may offer better long-term value.

What is the difference between F61 and the other F6x codes on a Glow-Worm boiler?

Glow-Worm classifies F61 through F68 as main board faults, but F61 is specifically linked to the gas valve control pathway on the PCB. F62–F67 relate to other aspects of board function (such as sensor input circuits or internal communication errors). If your display shows F61, the focus of diagnosis will be the PCB's gas valve output and the valve itself — whereas other F6x codes may point the engineer toward different sections of the board.

My Glow-Worm boiler keeps coming back to F61 after a reset — is it safe to keep resetting it?

No. A single reset is reasonable to try, but if F61 returns each time, there is a genuine component fault that resetting will not resolve. Repeatedly resetting a boiler with an active gas valve or PCB fault does not make the boiler safer — it just delays the inevitable repair and may allow a worsening fault to cause additional damage. Book a Gas Safe engineer promptly rather than cycling through resets.

Affected models: Glow-Worm Energy, Glow-Worm Flexicom, Glow-Worm Ultimate, Glow-Worm Betacom, Glow-Worm Easicom, Glow-Worm Hideaway

Last reviewed 30 June 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Glow-worm F61 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →