Daikin 8F-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin 8F-00 fault code mean?

The 8F-00 code tells you that the heat pump's control system has lost confidence in the reading from the second suction pipe temperature sensor used during heating on System 1. This thermistor monitors refrigerant conditions at the suction side of the circuit; when the controller detects a signal that is absent, erratic, or outside the expected range, it raises this alarm and prevents the system from running heating. On multi-system Daikin units, code 8E covers System 1's first suction thermistor and 8F covers the second — on a single-system installation, 8F still refers specifically to this secondary sensor on System 1.

Lockout — engineer likely 5 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Confirm the active fault code on your controller DIY safe

    On a Daikin wired remote or indoor controller, press and hold the CANCEL button for approximately five seconds until the display shows '00' and the unit beeps. Press CANCEL repeatedly to step through stored codes — a long beep indicates the active fault. Note the code (8F-00), then press CANCEL once more to exit diagnostic mode. This confirms the fault before calling an engineer.

  2. Check the outdoor unit isolator and any tripped MCBs DIY safe

    Head to your consumer unit and confirm that the heat pump circuit breaker has not tripped. Also check that the outdoor unit's local isolator switch (usually mounted on the wall beside the unit) is in the ON position. A brief power interruption sometimes causes a fault to latch; if everything looks normal, switch the unit off at the isolator, wait two minutes, then switch back on to attempt a reset. If the 8F-00 code returns, the underlying fault is genuine and requires an engineer.

  3. Clear any debris or obstructions from around the outdoor unit DIY safe

    While this step will not resolve a thermistor fault, it is worth doing before the engineer arrives. Remove any leaves, snow, ice or other debris from the outdoor unit's casing, fan grille and the area immediately around it. This ensures good airflow and rules out any secondary issues that could complicate the engineer's diagnosis.

  4. Have an engineer inspect and reseat the thermistor wiring and connectors heat pump engineer

    An MCS-certified engineer will open the outdoor unit and locate the suction pipe thermistor wiring harness. They will check each connector for signs of corrosion, pin damage or a loose crimp, reseat any suspect connections and clear any moisture. If the harness itself is damaged, it will be replaced. After reseating, the engineer will clear the fault code and test the unit to see whether the error returns.

  5. Test the thermistor resistance and replace the sensor if faulty heat pump engineer

    Using a multimeter, the engineer will measure the thermistor's resistance and compare it against Daikin's reference values at the current ambient temperature. A reading that is open-circuit, short-circuit or significantly outside the expected range confirms the sensor has failed. Replacement involves fitting a new, compatible Daikin thermistor, clipping it correctly to the suction pipe and reconnecting the wiring harness before retesting.

  6. Inspect and replace the outdoor unit main PCB if required heat pump engineer

    If the thermistor and all wiring test as good, the fault lies with the outdoor PCB's ability to process the sensor signal. The engineer will carry out further electrical checks on the board before condemning it. PCB replacement on a Daikin outdoor unit is a specialist task involving careful handling of the refrigerant-circuit connections and correct programming of the new board to match the installation.

  7. Contact an MCS-certified heat pump engineer heat pump engineer

    Because every step beyond the basic checks above involves working inside the outdoor unit — and potentially near the refrigerant circuit — you should book an MCS-certified heat pump engineer. If the fault is traced to a refrigerant-side component, only an F-Gas registered engineer is legally permitted to handle the sealed circuit. Daikin's UK Approved Service Partner network can typically source thermistors and PCBs next-day from the UK distribution centre, so most 8F-00 faults are resolved on the first or second visit.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £180–£350, depending on the underlying cause.

Frequently asked questions

Can I keep using my Daikin heat pump while the 8F-00 code is showing?

No. The 8F-00 fault will lock out heating mode because the system can no longer monitor suction pipe conditions reliably. Running the heat pump without this protection risks the compressor operating outside safe parameters. Leave the unit off and book an engineer promptly — particularly important in cold weather when you need heating.

Is the 8F-00 fault covered under my Daikin warranty?

It may be. Daikin's standard residential warranty covers component faults for three years (some extended schemes offer longer), provided the unit has been serviced annually by an F-Gas certified engineer and you have the service records to prove it. Wear-and-tear failures — such as a thermistor that has simply reached the end of its service life — are typically not covered. Contact your installer or a Daikin Approved Service Partner with your installation and service paperwork before authorising any repair.

How much does it cost to fix an 8F-00 fault in the UK?

The majority of 8F-00 faults come down to a failed thermistor or a loose connector. A sensor swap including engineer call-out, parts and labour typically costs £180–£350. If the outdoor PCB turns out to be the cause, expect to pay £450–£900 for the board plus labour. These are the two scenarios that cover the vast majority of cases. In rare situations where a refrigerant-circuit component contributes to the fault, costs can be higher — your engineer will advise once they have diagnosed the root cause.

How can I prevent the 8F-00 fault from recurring?

Annual servicing by an MCS-certified, F-Gas registered engineer is the single most effective measure. During a service, the engineer will check all thermistor readings and connections, clean the outdoor unit coil and fan, and verify refrigerant pressures — catching sensor degradation before it causes a lockout. Keeping the outdoor unit clear of debris and ensuring good airflow around it year-round also reduces stress on the system's components.

Affected models: Daikin Altherma 3, Daikin Altherma R32, Daikin Altherma LT, Daikin Multi-Split (System 1 units), Daikin Altherma HT

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin 8F-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →