Daikin 8H-03 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin 8H-03 fault code mean?

The 8H-03 fault code indicates that the heat pump's internal safety thermostat has detected dangerously high water temperatures within the heating circuit and has triggered a protective lockout. Unlike 8H-00, which flags an abnormal rise in outlet water temperature as an early warning, 8H-03 means the thermostat protection device itself has tripped — signalling a more severe or sustained overheating event. The system will not restart automatically; a manual reset is required. This code is generated by the indoor/hydronic unit and points to a problem with water flow, circulation, or temperature sensing rather than anything in the refrigerant circuit.

Lockout — engineer likely 4 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Check that radiator valves, TRVs, and underfloor heating manifold valves are at least partially open DIY safe

    Walk around the property and confirm that not all TRVs or zone valves are fully closed. At least a portion of the circuit must be open for water to circulate. If every valve in the house is shut, open several partially and attempt a reset. This costs nothing and takes minutes.

  2. Check system pressure on the pressure gauge DIY safe

    Locate the pressure gauge on the indoor unit or on the buffer vessel — it should normally read between 1.0 and 1.5 bar when cold. If it reads below 1 bar, repressurise via the filling loop following the instructions in your Daikin user manual. Do not overpressurise beyond 2.5 bar. If the system loses pressure repeatedly, there may be a leak that requires a professional to investigate.

  3. Clear any obstructions from around the outdoor unit DIY safe

    While 8H-03 is primarily a water-side fault, it is good practice to confirm the outdoor unit has adequate airflow. Remove any leaves, debris, or snow that may have built up around the unit. Do not pour hot water on a frosted outdoor unit — allow it to defrost naturally or via the heat pump's own defrost cycle.

  4. Attempt a single manual reset from the controller DIY safe

    Navigate to the fault or alarm section of your Daikin controller and perform one manual reset. Allow the system to restart and monitor it for 15–20 minutes. If the 8H-03 code returns promptly, do not keep resetting — repeated restarts while a flow restriction exists can force the compressor to work against a bottleneck and risk serious damage. One reset attempt is reasonable; more than that risks turning a relatively minor repair into a much more expensive one.

  5. Contact Daikin UK to check your warranty status before booking a third-party engineer DIY safe

    Daikin Altherma systems installed by a Daikin D1 or D2 registered installer carry a five-year parts and labour warranty, provided the warranty was registered at daikin.co.uk/warranty within 30 days of installation. If your system is within warranty, log the fault with Daikin UK first — the repair may be covered at no cost to you.

  6. Arrange a visit from an MCS-certified heat pump engineer for diagnosis and repair heat pump engineer

    If the fault returns after a single reset, or if you cannot identify an obvious cause such as closed valves or low pressure, a qualified engineer must carry out a full diagnosis. They will test the circulation pump for correct speed, pressure, and operation; clean or replace any blocked filters or strainers; check the leaving and returning water thermistors for accuracy and secure mounting; verify the bypass valve is correctly installed and set; inspect zone valves and actuators; and assess the hydronic PCB if the pump appears to be receiving incorrect control signals. Do not attempt to work on any of these components yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£550, depending on the underlying cause.

Frequently asked questions

Why does the Daikin 8H-03 fault require a manual reset — will it clear itself?

No, 8H-03 will not clear automatically. Because the safety thermostat has physically tripped in response to dangerously high water temperatures, Daikin's design requires a deliberate manual reset by the user or engineer before the system will attempt to restart. This is intentional — it ensures someone has investigated the cause before the heat pump tries to run again. You can attempt one reset yourself via the controller, but if the fault returns, stop resetting and call an engineer.

Can I keep resetting the 8H-03 fault to get my heating back on?

This is strongly inadvisable. Each time you reset and run the heat pump with a flow restriction in place, the compressor is forced to operate under abnormal conditions. What might be a straightforward fix — such as a filter clean costing around £100–£200 — can escalate into compressor damage costing well over £1,500 if the unit is run repeatedly in an overheating state. One reset attempt is reasonable; beyond that, switch the system off and wait for an engineer.

Is my Daikin Altherma covered under warranty for an 8H-03 fault?

Possibly, yes. Daikin Altherma systems installed by a D1 or D2 registered Daikin installer come with a five-year parts and labour warranty, provided the warranty was registered at daikin.co.uk/warranty within 30 days of installation. If your system is within that period, contact Daikin UK before booking an independent engineer — Daikin have their own service network and may carry out the diagnosis and repair at no charge to you.

How much does it typically cost to fix a Daikin 8H-03 fault in the UK?

For the most common causes — a blocked filter, a faulty thermistor, or a circulation pump issue — most UK homeowners pay somewhere between £150 and £550 including call-out and labour. A circulation pump replacement typically falls in the £200–£500 range; a thermistor is usually £150–£300 all-in. A hydronic PCB is less common and tends to cost £300–£800 to replace. In rare cases where repeated overheating has caused compressor damage, costs can exceed £1,500 — which is why catching and resolving this fault promptly matters so much.

Affected models: Daikin Altherma 3 H HT F, Daikin Altherma 3 R F, Daikin Altherma 08CA, Daikin Altherma air-to-water heat pumps (general)

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin 8H-03 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →