Ferroli A39 Fault Code: Causes, Fixes & Repair Costs

What does the Ferroli A39 fault code mean?

The A39 code indicates that the boiler has detected a problem with the external (outside air temperature) probe — an optional sensor that, when fitted, allows the boiler to modulate its output based on outdoor conditions, a feature known as weather compensation. The boiler has lost a valid signal from this sensor, either because it is damaged, disconnected, or was enabled in the boiler's configuration but never properly installed. Because A-prefix codes are lockout faults on Ferroli boilers, the boiler will shut down and require a manual reset to restart. It will not clear on its own.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 3 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Attempt a boiler reset DIY safe

    Locate the reset button on your Ferroli boiler — it is usually marked with an 'R' or a flame symbol. Press and hold it for 5–10 seconds. If the fault clears and the boiler fires up normally, monitor it over the next few hours. If A39 returns, move on to the next step rather than repeatedly resetting.

  2. Visually inspect the external sensor and its cable DIY safe

    The outside air temperature sensor is typically a small probe clipped or screwed to an external wall. Without opening the boiler casing, check whether the sensor is still physically in place and that its cable appears intact — no obvious cuts, chew marks, or sections pulled away from the wall. Note any visible damage to report to your engineer.

  3. Contact a Gas Safe registered engineer to inspect and reconfigure or replace the sensor Gas Safe engineer

    If the fault returns after a reset, or if you can see cable or sensor damage, you need a Gas Safe engineer. They can: test the sensor's resistance to confirm whether it has failed; re-seat any loose wiring connections; disable the external probe setting in the boiler's configuration menu if weather compensation is no longer required (this is often the quickest permanent fix); or replace the sensor if it has genuinely failed.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£150, depending on the underlying cause.

Frequently asked questions

Can I just disable the external probe setting to clear the A39 fault?

Yes — if you no longer need or use weather compensation, a Gas Safe engineer can turn off the external probe function in the boiler's configuration menu. Once disabled, the boiler stops expecting a sensor signal and the A39 fault should clear permanently. This is often the cheapest and quickest resolution, covered within a standard call-out fee of roughly £80–£120.

Is the A39 fault dangerous?

Not directly. Unlike faults related to gas pressure, combustion, or flue gases, A39 is about an optional temperature sensor rather than a core safety system. However, you should still arrange a fix promptly — the boiler is in lockout and will not provide heating or hot water until the fault is resolved. As always, if you smell gas or notice any leak, leave the property and call the National Gas Emergency Service on 0800 111 999 immediately.

How much does it cost to fix a Ferroli A39 fault?

Because A39 involves an inexpensive optional sensor, it is one of the more affordable Ferroli fault repairs. A call-out, diagnosis, and configuration change (disabling the probe setting) typically costs £80–£150. If the sensor itself needs replacing, parts are cheap — usually under £30 — so an all-in replacement is often only marginally more. Labour rates vary by region, so always get a quote upfront.

My Ferroli boiler keeps returning to A39 after I reset it — what should I do?

A fault that keeps coming back after a reset almost always means the underlying problem has not been fixed. Stop resetting the boiler repeatedly and call a Gas Safe engineer to properly diagnose the cause — whether that is a failed sensor, damaged wiring, or a configuration setting that needs changing. Repeated lockout and restart cycles without resolving the root cause can place unnecessary stress on other boiler components.

Affected models: DOMIcondens HE 26 C, OPTIMAX HE PLUS 31C, OPTIMAX HE PLUS 38C

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ferroli A39 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →