Ferroli A41 Fault Code: Causes, Fixes & Repair Costs

What does the Ferroli A41 fault code mean?

The A41 code is a manual lockout fault on Ferroli boilers — meaning the boiler shuts itself down and will not restart without you pressing the reset button first. It points to a problem with the flow (CH) temperature sensor, also known as the NTC thermistor. This is the component responsible for monitoring how hot the water leaving the boiler is. When the boiler cannot get a reliable reading from this sensor — whether because the sensor has physically shifted away from the flow pipe, its wiring has come loose, or the sensor itself has failed — it triggers A41 and locks out as a safety precaution. In essence, the boiler has lost confidence in its own temperature data and refuses to fire until the situation is resolved.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Press the reset button to attempt to clear the lockout DIY safe

    Locate the reset button on your Ferroli boiler — it is usually marked with an 'R' symbol or a flame icon. Press and hold it for approximately 5 seconds until the boiler attempts to restart. If the boiler fires up and the A41 code does not return within a short period, the fault may have been a temporary one-off. Do not reset the boiler more than two or three times in total — repeated resets without fixing the underlying cause can damage the heat exchanger.

  2. Check that the fault code does not immediately return DIY safe

    After resetting, keep an eye on the boiler display for the next 15–30 minutes. If A41 reappears quickly or the boiler fails to restart at all, there is a genuine fault with the sensor or its wiring that needs a qualified engineer to diagnose. Do not continue resetting in the hope it will eventually clear.

  3. Contact a Gas Safe registered engineer for diagnosis Gas Safe engineer

    A Gas Safe engineer will physically inspect the flow sensor to check whether it has simply moved out of position on the pipe — the official Ferroli guidance specifically advises checking the sensor's positioning and contact. If repositioning resolves it, the fix is straightforward. If not, they will test the thermistor's resistance with a multimeter to determine whether the sensor itself has failed and needs replacing.

  4. Engineer to test and replace the flow NTC thermistor if required Gas Safe engineer

    If the sensor is confirmed faulty, the engineer will fit a replacement NTC thermistor suitable for your Ferroli model. Ferroli parts are generally competitively priced, though lead times can be longer on older or discontinued models. Once replaced, the engineer will reset the boiler, run it through a heating cycle, and confirm the fault has cleared and temperature readings are within normal range.

  5. Engineer to inspect wiring and PCB if sensor replacement does not resolve the fault Gas Safe engineer

    Should A41 persist after a new sensor is fitted, the engineer will trace the wiring loom from the sensor to the PCB looking for corrosion, chafing, or a failed connector. If the wiring is sound, attention turns to the control board itself, which may need replacing — a more costly repair that is worth weighing against the age of the boiler.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £90–£200, depending on the underlying cause.

Frequently asked questions

Can I fix the Ferroli A41 fault code myself?

The only safe DIY step is pressing the reset button — once or twice at most. Everything else, including checking the sensor's position, testing it with a multimeter, or replacing it, involves accessing the internals of the boiler and should only be done by a Gas Safe registered engineer. Attempting internal repairs yourself is unsafe and will invalidate any remaining warranty.

How much does it cost to fix an A41 fault on a Ferroli boiler?

For most people, the repair involves either repositioning the existing sensor (low cost — mainly a call-out and labour fee of roughly £90–£120) or replacing the NTC thermistor (typically £90–£200 including parts and labour). If the fault turns out to be a wiring issue, costs are similar. A PCB replacement is a more expensive outlier — typically £250–£350 all in — but this is rarely the cause of an A41 code and would only be considered after the sensor and wiring have been ruled out.

Why does the A41 code keep coming back after I reset it?

If A41 returns repeatedly after resetting, it means the underlying hardware fault has not been resolved. Resetting only clears the lockout temporarily — it does not repair a displaced, damaged, or wiring-faulted sensor. Continuing to reset without fixing the cause risks damaging other components such as the heat exchanger. Book an engineer to diagnose and repair the root cause.

Is A41 the same as an F10 fault on a Ferroli boiler?

They are related but not identical. F10 on a Ferroli boiler also indicates a flow sensor issue — typically a short circuit or open circuit on the NTC thermistor — and is a blocking fault that may clear automatically once conditions improve. A41 is a harder lockout that always requires a manual reset. Both ultimately point to the same component (the flow temperature sensor), so the diagnosis and repair process is very similar.

Affected models: Ferroli Modena HE S, Ferroli Modena HE, Ferroli Optimax HE, Ferroli BlueHelix, Ferroli Sigma, Ferroli Domiproject

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ferroli A41 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →