What does the Ferroli F35 fault code mean?

The F35 code on a Ferroli boiler indicates that the boiler's control board has detected an irregular or unstable mains electrical frequency. The UK grid should supply alternating current at a steady 50Hz; when the frequency deviates outside acceptable limits, the boiler raises this fault to protect itself. F35 is an F-type blocking fault on Ferroli boilers, which means it may clear on its own once the underlying condition resolves — unlike A-type lockout codes, which always need a manual reset. Because the fault points squarely at the incoming electricity supply rather than at the gas or heating circuit, the first call should be to a qualified electrician rather than a Gas Safe engineer.

Engineer may be needed May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Attempt a single boiler reset DIY safe

    Locate the reset button on your Ferroli boiler — it is usually marked with an 'R' or a flame symbol. Press and hold it for around 5–10 seconds. If the boiler fires up normally and the fault does not return, the issue was likely a brief, one-off mains disturbance. Do not reset more than two or three times in total; repeated resets without a fix will not solve the underlying problem and can stress the boiler further.

  2. Check for any obvious electrical issues in your home DIY safe

    Look at your consumer unit (fuse box) to see whether any circuit breakers have tripped. Check that other mains-powered appliances in the home are working normally. If lights are flickering or other devices are behaving oddly, this supports a mains supply problem rather than a boiler fault.

  3. Call a qualified electrician to test the incoming mains frequency DIY safe

    Ask a qualified electrician to measure the frequency of the electricity supply reaching the boiler with a calibrated meter. They should confirm it is stable at 50Hz and check the boiler's dedicated fused spur for loose connections, corrosion, or wiring faults. This step should happen before any boiler components are replaced, as it may identify a cheap fix.

  4. If mains supply is confirmed healthy, call a Gas Safe registered engineer to inspect and replace the PCB Gas Safe engineer

    Once an electrician has confirmed the incoming supply is normal and stable, the fault almost certainly lies within the boiler's control board. A Gas Safe registered engineer will test the PCB, confirm the diagnosis, and replace it with a compatible unit. This is not a DIY job — do not attempt to open the boiler casing or handle internal electrical components yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £130–£320, depending on the underlying cause.

Frequently asked questions

Is the Ferroli F35 a lockout fault or will it clear by itself?

F35 is an F-type blocking fault on Ferroli boilers, which means it can clear automatically once the underlying condition — in this case an unstable mains frequency — goes away. This is different from an A-type lockout code, which always needs a manual reset button press before the boiler will fire again. If your F35 disappears on its own and does not return, a brief grid disturbance was most likely responsible. If it keeps coming back, you need an electrician or Gas Safe engineer to investigate.

Can I fix the Ferroli F35 myself?

The only homeowner action that is safe and appropriate is a single boiler reset (no more than two or three times). Beyond that, checking the mains frequency requires specialist electrical test equipment, and replacing the PCB requires opening the boiler — both need qualified professionals. Call a qualified electrician first to test the supply frequency; if they confirm the supply is fine, book a Gas Safe registered engineer to assess the control board.

How much does it cost to fix a Ferroli F35 fault?

Most people pay somewhere between £130 and £320 all-in. An electrician visit to test the mains supply typically costs £50–£100, and if the PCB turns out to be the culprit, parts and labour for a replacement board usually run to £200–£320. In rare cases — particularly on older or discontinued Ferroli models where the PCB has to be sourced specially — the board alone can exceed £300, pushing total costs higher. If your boiler is over ten years old and the repair is approaching 40% of the cost of a new boiler, replacement is often the more sensible long-term investment.

Why does my Ferroli boiler show F35 even though the rest of my house electrics seem fine?

The boiler's PCB is sensitive to frequency variations that would not be noticeable to other household appliances. Everyday devices such as televisions and kettles tolerate small fluctuations without any visible effect, whereas the boiler's control board is programmed to flag even relatively minor deviations. It is also possible the PCB's own frequency-monitoring circuit has developed a fault, causing it to report a problem that does not actually exist in the supply. An electrician can rule out a real supply issue, after which a Gas Safe engineer can determine whether the board itself needs replacing.

Affected models: Ferroli Modena, Ferroli Optimax, Ferroli BlueHelix, Ferroli Domicompact, Ferroli Econcept

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ferroli F35 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →