Grant A7 Fault Code: Causes, Fixes & Repair Costs

What does the Grant A7 fault code mean?

A7 on a Grant Aerona³ heat pump reports a defrost temperature sensor error: the thermistor on the outdoor coil that tells the controller when frost is forming — and when a defrost cycle has finished — has failed or is reading implausibly. Air source heat pumps frost their outdoor coil routinely in UK winters and rely on this sensor to time defrosts correctly: too few and the coil ices into a solid block, too many and efficiency drains away. With the reading untrustworthy the unit stops rather than mismanage defrosting. Grant's documented remedy is direct — a faulty sensor should be replaced — and diagnosis is the usual resistance check.

Engineer may be needed 4 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Power-cycle once at the external isolator DIY safe

    Switch the heat pump off at its external rotary isolator, wait about three minutes for the inverter capacitors to discharge, and switch back on. One controlled restart is legitimate; if the code returns, leave it for an engineer.

  2. Glance at the outdoor coil DIY safe

    If the coil is visibly caked in ice, mention it when booking — it suggests defrosting has been mistimed for a while. Do not chip ice off; the fins damage easily and the ice will melt once the unit is repaired.

  3. Have a suitably qualified heat pump engineer complete the documented checks heat pump engineer

    The engineer will measure the defrost sensor's resistance, check its mounting position and wiring, replace the faulty sensor, and confirm a defrost cycle initiates and terminates correctly afterwards. Work on the sealed refrigerant circuit legally requires an F-Gas registered engineer; your installer or a Grant-accredited (G1) installer is the right call, and Grant UK technical support (01380 736920) can assist with diagnosis.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£280, depending on the underlying cause.

Frequently asked questions

What does A7 mean on my Grant Aerona³?

The sensor that manages the outdoor coil's defrost cycles has failed. Without it the unit cannot time defrosting safely, so it stops. An engineer confirms the sensor with a resistance check and replaces it — a quick, inexpensive repair as heat pump faults go.

Is frost on my heat pump normal then?

Yes — an air source heat pump frosting its coil on cold, damp days is completely normal, and it defrosts itself automatically. A coil encased in solid ice is the abnormal sign, and often means the defrost sensor or cycle has been misbehaving.

Can I pour warm water over the iced coil?

Best not — sudden thermal shock and refreezing underneath the unit cause their own problems, and the fins are delicate. Let the engineer deal with the cause; the ice clears naturally once defrosting works again.

Affected models: Grant Aerona³ R32 HPID6R32, Grant Aerona³ R32 HPID10R32, Grant Aerona³ R32 HPID13R32, Grant Aerona³ R32 HPID17R32

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Grant A7 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →