Grant E8 Fault Code: Causes, Fixes & Repair Costs

What does the Grant E8 fault code mean?

The E8 fault code on the Grant Aerona³ air source heat pump indicates that the unit has entered a protective shutdown due to unreasonable or overload operating conditions. This is most commonly triggered by restricted airflow at the outdoor unit's air inlet or outlet, or by an incorrect refrigerant charge. When the system detects it is operating outside safe parameters — unable to move or exchange heat effectively — it shuts down to prevent damage to the compressor and other components. The fault is displayed as E8 on the Aerona Remote Controller (accompanied by a flashing red LED) and on the terminal PCB LED display on the outdoor unit itself.

Lockout — engineer likely 5 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Inspect the area around the outdoor unit and clear any obstructions DIY safe

    Walk around the outdoor unit and remove any leaves, garden debris, plant growth or other objects blocking the air inlet grille or the outlet at the top or sides. Grant and most manufacturers recommend at least 300mm of clear space around the unit. In winter, check for compacted snow or ice around the base and grilles — carefully clear these by hand or with lukewarm water (never boiling water or a sharp implement that could damage the fins).

  2. Check that the outdoor unit fan is visible and not physically jammed DIY safe

    With the unit powered off at the isolator, visually inspect the fan blade through the outlet grille. Confirm there is no debris wedged in the fan. Do not reach into the unit or attempt to spin the blade manually. If you can see the blade is visibly bent or damaged, note this for the engineer.

  3. Power the unit down at the external isolator and wait at least three minutes before restarting DIY safe

    Switch off the outdoor unit at the dedicated isolator (usually a red or grey weatherproof switch mounted on the wall near the unit). Wait a full three minutes to allow the control board to fully reset. Then switch the isolator back on and observe the controller. If the E8 code clears and the unit returns to normal operation, monitor it closely over the next few hours. Note that Grant advises homeowners against manually resetting fault codes on the Aerona Remote Controller — if the unit does not restart cleanly on its own after power restoration, leave the reset to your engineer.

  4. Check your system pressure and top up if below the recommended range DIY safe

    While the E8 code is not directly caused by low system water pressure, confirming that your heating circuit is within the correct pressure range (typically 1.0–2.0 bar when cold, as shown on your system pressure gauge) rules out any secondary issues. If pressure is low, top up via the filling loop in the usual way. If you are unsure how to do this safely, leave it to your engineer.

  5. If the fault persists, contact an MCS-certified heat pump engineer heat pump engineer

    If the E8 code returns after clearing obstructions and a clean power cycle, the underlying cause is likely to require professional investigation. An MCS-certified engineer will inspect and clean the outdoor coil, test the fan motor electrically, check operating pressures and — if a refrigerant-circuit fault is confirmed — carry out recovery and recharge work. Any refrigerant handling must legally be carried out by an F-Gas registered engineer. The engineer will also test all relevant temperature sensors against the resistance tables in the Aerona³ service manual and, if required, replace the main PCB.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£450, depending on the underlying cause.

Frequently asked questions

Can I reset the E8 fault code on my Grant Aerona³ myself?

Grant's own guidance is clear that homeowners should not attempt to manually reset fault codes on the Aerona Remote Controller. Some codes clear automatically once the underlying issue is resolved, but others require a manual reset by a trained engineer. The safest approach is to switch the unit off at the external isolator, wait three minutes, and switch it back on. If the E8 code does not clear on its own after that, call your installer or an MCS-certified engineer rather than attempting a controller-level reset yourself.

Why does my Grant Aerona³ show E8 in winter — could it be snow or ice?

Yes, this is one of the more common winter triggers for the E8 fault. Snow accumulation around the base of the unit, or ice forming over the air inlet grilles, can restrict airflow enough to push the system into overload protection. Carefully clear any snow or ice from around the unit (do not use sharp tools near the fins) and ensure the area immediately around the outdoor unit is free from obstruction. If the fault clears after this and does not return, no further action is needed beyond keeping the area clear during cold spells.

How much does it cost to fix an E8 fault on a Grant Aerona³?

For the most common causes — a professional coil clean, airflow check and service visit — most homeowners pay in the region of £120 to £300. If the refrigerant charge needs to be corrected (recovered and recharged by an F-Gas registered engineer), expect costs of roughly £200 to £450 depending on the amount of refrigerant required and travel time. More involved repairs such as a fan motor replacement typically fall in the £250–£500 range including parts and labour. A main PCB replacement is less common but can cost £500–£900 or more — if your engineer suspects this, it is worth getting a written quote before proceeding.

How can I prevent the E8 fault from happening again?

Annual servicing by an MCS-certified engineer is the most effective preventive measure — the engineer will clean the outdoor coil, check refrigerant pressures, test sensors and inspect the fan, catching any developing issues early. Between services, keep the area around the outdoor unit clear of vegetation and debris, and check after heavy snowfall in winter. Keeping your service schedule up to date also protects your manufacturer warranty with Grant.

Affected models: Grant Aerona³ 6kW, Grant Aerona³ 10kW, Grant Aerona³ 13kW, Grant Aerona³ 17kW, Grant Aerona³ Monobloc Series

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Grant E8 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →