Grant C4 Fault Code: Causes, Fixes & Repair Costs

What does the Grant C4 fault code mean?

The C4 fault code on the Grant Aerona³ heat pump indicates a problem with the outgoing (flow) water temperature sensor — the NTC thermistor that monitors the temperature of water leaving the heat pump. When this sensor reports a reading outside its expected range, the controller flags C4 and may lock out the unit to protect the system. The fault code appears on the Aerona³ Remote Controller display alongside a warning icon and a flashing red LED, and is simultaneously shown on the Terminal PCB LED display inside the outdoor unit.

Lockout — engineer likely 3 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Check for an obvious system reset first DIY safe

    Before calling an engineer, switch the heat pump off at the external isolator, wait at least three minutes to allow the system electronics to fully discharge, then switch it back on. In some cases a transient sensor error will clear automatically once the heat pump returns to normal operation. If C4 reappears, do not attempt further resets yourself — note down the code and call your installer or an MCS-certified heat pump engineer.

  2. Inspect the sensor wiring harness and connectors heat pump engineer

    An engineer will check the wiring harness running from the outgoing water temperature sensor to the main PCB. They will look for loose terminals, signs of corrosion, and any mechanical damage to the cable. Corroded or loose connectors are cleaned, tightened, or replaced as needed.

  3. Test the NTC sensor resistance heat pump engineer

    Using a calibrated multimeter, the engineer measures the sensor's resistance and compares it against the temperature/resistance table in the Grant Aerona³ installation manual (Fault Finding section). An out-of-tolerance reading confirms the sensor has failed and must be replaced.

  4. Replace the outgoing water temperature sensor heat pump engineer

    If the resistance test confirms a faulty thermistor, the engineer replaces it with the correct OEM-specified NTC sensor. The probe is seated properly in its pocket and all connectors are secured before the system is restarted and retested.

  5. Investigate the main PCB if the sensor tests correctly heat pump engineer

    Should the sensor and wiring both test within specification yet C4 returns after a full power cycle, the main PCB is likely at fault. PCB replacement is a more involved job and typically the most costly outcome of a C4 fault — your engineer will confirm whether repair or replacement is appropriate.

  6. Arrange a manual fault-code reset and system recommission heat pump engineer

    Grant's guidance is clear that a C4 lockout should only be manually reset by a qualified heating engineer or your original installer — not the homeowner. Once the root cause is resolved, the engineer resets the code either via the Aerona³ Remote Controller menu or via the Terminal PCB, then verifies the heat pump returns to normal operation.

  7. Contact an MCS-certified heat pump engineer if you have not already done so heat pump engineer

    If the unit has not recovered after a single power-cycle reset, book a visit from an MCS-certified heat pump engineer. For work involving the refrigerant circuit, ensure the engineer is also F-Gas registered. Using a Grant-accredited engineer also helps protect any remaining warranty — Grant UK's website includes an installer locator tool.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£380, depending on the underlying cause.

Frequently asked questions

Can I reset the Grant Aerona³ C4 fault code myself?

Grant's own guidance advises homeowners not to manually reset fault codes on the Aerona³ Remote Controller. Some codes clear automatically once the underlying fault is resolved, while others require a manual reset by your installer or a qualified engineer. You can try a single power-cycle at the external isolator (off, wait three minutes, back on), but if C4 reappears you should call your engineer rather than repeatedly resetting — doing so without fixing the root cause can mask a developing problem.

How much does it cost to fix a Grant Aerona³ C4 fault in the UK?

For the most common outcome — a failed outgoing water NTC sensor — you are typically looking at £150 to £380 including the engineer's call-out, the replacement part, and labour. If the sensor tests fine and the fault turns out to be the main PCB, costs rise considerably; a PCB replacement can bring the total to £500–£800 or more. Getting a quote before work proceeds is always advisable.

Will my Grant Aerona³ still produce heat with a C4 fault showing?

It depends on the severity. In some cases the heat pump may continue running at reduced capacity while logging C4; in others it will lock out completely and stop heating or providing hot water. If the unit has locked out, your home will lose heating and hot water until the fault is cleared — so it is worth arranging an engineer visit promptly, particularly in colder months.

Can a dirty or poorly maintained system cause the C4 fault?

Indirectly, yes. Heavily contaminated system water or sludge build-up can cause localised temperature stratification around the sensor pocket, producing erratic readings. Using the correct inhibitor concentration and having the system flushed during annual servicing reduces the risk of sensor-related faults. Grant recommends annual servicing of Aerona³ units, which typically includes checking sensor readings and electrical connections — the kind of checks that can catch a deteriorating thermistor before it triggers a lockout.

Affected models: Grant Aerona³ R32, Grant Aerona³ HPID12R32, Grant Aerona³ (all Aerona³ variants — confirm against your installation manual)

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Grant C4 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →