Grant L4 Fault Code: Causes, Fixes & Repair Costs

What does the Grant L4 fault code mean?

L4 on a Grant Aerona³ heat pump reports a mix water temperature sensor error: the thermistor measuring temperature at a mixing point — used on installations with a mixed (blended) circuit, most commonly underfloor heating running cooler than the radiator circuit — has failed or reads implausibly. The controller blends flow water down to the mixed circuit's target using that reading; without it, it cannot guarantee the underfloor loops are protected from full-temperature flow, so the affected circuit stops. Grant's documented diagnosis is a resistance check with a tester, and the remedy the standard one: a faulty sensor is replaced. This code auto-resets once the reading returns to normal.

Engineer may be needed 4 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Note which circuits are affected DIY safe

    L4 concerns the blended circuit — typically underfloor heating. If radiators still heat while the underfloor stays cold, that pattern confirms it and is useful to report when booking.

  2. Have a suitably qualified heat pump engineer complete the documented checks heat pump engineer

    The engineer will measure the mix sensor's resistance with a tester (Grant's documented method), inspect its wiring and seating at the mixing valve or manifold, and replace the faulty sensor — the code auto-resets once a valid reading returns. Work on the sealed refrigerant circuit legally requires an F-Gas registered engineer; your installer or a Grant-accredited (G1) installer is the right call, and Grant UK technical support (01380 736920) can assist with diagnosis.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£260, depending on the underlying cause.

Frequently asked questions

What does L4 mean on my Grant Aerona³?

The sensor at the mixing point — where flow water is blended down for a cooler circuit like underfloor heating — has failed. That circuit stops so the floor loops cannot be fed full-temperature water. An engineer confirms the sensor with a resistance test and replaces it; the code clears itself once the reading is valid.

Why do my radiators work but the underfloor doesn't?

That is exactly the L4 signature: the fault sits on the blended circuit's sensor, so only that circuit is stopped. It is protective — underfloor pipework and floor coverings are specified for low temperatures.

Do I even have a mix circuit?

If your system is radiators-only on a single temperature, possibly not — some L4 configurations relate to how the installation was set up. Quote your model and system layout to the engineer; a sensor configured but not fitted, or vice versa, produces exactly this kind of code.

Affected models: Grant Aerona³ R32 HPID6R32, Grant Aerona³ R32 HPID10R32, Grant Aerona³ R32 HPID13R32, Grant Aerona³ R32 HPID17R32

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Grant L4 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →