GGrant logo

Grant L0 Fault Code: Causes, Fixes & Repair Costs

What does the Grant L0 fault code mean?

L0 on a Grant Aerona³ heat pump is an EEPROM error on the controller: the non-volatile memory holding the controller board's configuration and stored settings has failed its integrity check. A controller that cannot trust its stored parameters cannot safely run a compressor, defrost logic and heating circuit, so the unit stops. Grant's documentation lists the remedy plainly — the controller PCB should be replaced when the error persists — with a power-off reset the documented first response, since a corrupted-but-recoverable memory state occasionally clears on a genuine cold restart. If L0 returns, it is a board replacement, followed by reconfiguration for your installation.

Stop & check now Some DIY checks possible 4 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Power off fully, wait three minutes, power on DIY safe

    Grant's documented reset for this code is a power-off restart. Switch off at the external isolator, wait a full three minutes, and switch back on — a genuine cold start is the only kind that counts.

  2. Have a suitably qualified heat pump engineer complete the documented checks heat pump engineer

    If L0 returns, the controller PCB is replaced per the documentation and reconfigured for your system — heating curves, cylinder settings and any zone arrangements — then proven through a full heating and hot water cycle. Work on the sealed refrigerant circuit legally requires an F-Gas registered engineer; your installer or a Grant-accredited (G1) installer is the right call, and Grant UK technical support (01380 736920) can assist with diagnosis.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £180–£420, depending on the underlying cause.

Frequently asked questions

What does L0 mean on my Grant Aerona³?

The controller board's stored memory failed its integrity check, so the unit stopped — it cannot safely run on settings it does not trust. Try one full power-off restart (three minutes off); if L0 returns, the controller PCB needs replacing and setting up again for your system.

Will my settings survive the repair?

The new board arrives blank, so the engineer reconfigures it — heating curve, hot water schedule, zones. If you know your installer set specific weather-compensation values, mention it; otherwise commissioning defaults plus a tidy-up visit get you back to normal.

Is this covered by warranty?

If the unit is registered and has its annual services, very likely — controller boards are exactly what manufacturer warranties are for. Check your registration before paying for parts.

Affected models: Grant Aerona³ R32 HPID6R32, Grant Aerona³ R32 HPID10R32, Grant Aerona³ R32 HPID13R32, Grant Aerona³ R32 HPID17R32

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Grant L0 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.