Grant U1 Fault Code: Causes, Fixes & Repair Costs

What does the Grant U1 fault code mean?

U1 on a Grant Aerona³ heat pump (the 13kW and 17kW HPID13R32/HPID17R32 models) is compressor overheat protection: the compressor's thermal protection has operated because it ran hotter than its safe limit. Grant's documentation names the underlying causes — refrigerant gas leakage, or the overheat relay operating — and its remedy is telling: recover the refrigerant and recharge with the prescribed mass. A compressor short of refrigerant loses the cooling effect the refrigerant flow itself provides and overheats; that makes U1 one of the codes most likely to involve the sealed circuit, which only an F-Gas registered engineer may legally open, leak-test and recharge.

Stop & check now 2 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Let it cool; restart once at most DIY safe

    After the compressor cools, one restart is reasonable. If U1 returns, stop — repeatedly running an overheating compressor is how a repair becomes a replacement.

  2. Have a suitably qualified heat pump engineer complete the documented checks heat pump engineer

    The engineer will check compressor temperatures and running conditions and, if refrigerant loss is suspected, leak-test the circuit, repair, recover and recharge with the prescribed mass — the documented remedy, and strictly F-Gas work. Work on the sealed refrigerant circuit legally requires an F-Gas registered engineer; your installer or a Grant-accredited (G1) installer is the right call, and Grant UK technical support (01380 736920) can assist with diagnosis.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£700, depending on the underlying cause.

Frequently asked questions

What does U1 mean on my Grant Aerona³?

On the 13kW and 17kW models, the compressor overheated and its protection shut it down. The documented cause is usually refrigerant loss — the compressor relies on refrigerant flow to keep itself cool — and the remedy is a leak-test, repair and weighed recharge by an F-Gas registered engineer.

Can refrigerant just be topped up?

Not properly — the charge is a prescribed mass, and 'topping up' a leaking system without finding the leak is both poor practice and environmentally regulated. The documented remedy is recover, repair, recharge to specification.

Is this the beginning of the end for my heat pump?

Not necessarily — a found-and-fixed leak with a fresh charge often restores years of service. But recurring U1 with a proven charge suggests compressor wear, and at that point an honest engineer will price the repair against the unit's age and warranty position for you.

Affected models: Grant Aerona³ R32 HPID13R32, Grant Aerona³ R32 HPID17R32

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Grant U1 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →