JSJohnson & Starley logo

Johnson & Starley E18 Fault Code: Causes, Fixes & Repair Costs

What does the Johnson & Starley E18 fault code mean?

E18 on a Johnson & Starley unit is the third of the stuck-sensor lockouts: a supervised temperature channel has frozen — the reading refuses to move while the unit's actual temperature changes. The controller cross-checks its sensors against expected behaviour every cycle, and a static value during heat-up fails that test immediately. As with E16 and E17 (the same supervision on the other channels), the code's job is to point the engineer at the right circuit; the underlying fault is a failed thermistor, a lead pinning the signal, or — rarely — the board input. The repair is short: confirm with a resistance check, replace the failed element, verify readings track through a full cycle.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset once and observe DIY safe

    Use the reset control (or switch off at the fused spur for 30 seconds and back on) a single time. If the code returns, stop resetting and book a Gas Safe registered engineer.

  2. Have a Gas Safe registered engineer complete the documented checks Gas Safe engineer

    The engineer will watch the affected sensor's live reading through a heat-up cycle — a healthy thermistor moves continuously; a stuck one sits flat. They will then measure its resistance against specification and replace the sensor, repair the wiring, or (rarely) replace the board.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £90–£250, depending on the underlying cause.

Frequently asked questions

What does E18 mean on my Johnson & Starley?

A temperature sensor has failed 'stuck' — its output stopped tracking the unit's real temperature, so the controller locked out. It is the same fault class as E16 and E17 on a different sensor channel. An engineer confirms which probe with a resistance check and replaces it.

Why are there three codes for the same fault?

Each code maps to a specific sensor circuit, which saves diagnostic time — the engineer goes straight to the right probe instead of testing them all. For the homeowner the meaning is identical: one failed temperature sensor.

How long is the repair?

Typically well under an hour once the engineer is on site with the sensor — access, measurement, replacement and a verification heat cycle. Cost usually lands £90–£250 depending on region and call-out terms.

Affected models: Johnson & Starley WarmCair CD, Johnson & Starley WarmCair CU, Johnson & Starley WarmCair DW, Johnson & Starley Economaire

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Johnson & Starley E18 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.