Keston E11 Fault Code: Causes, Fixes & Repair Costs

What does the Keston E11 fault code mean?

The E11 code indicates that your Keston boiler's control board has detected an internal electronics fault. In plain terms, the PCB (printed circuit board) — the brain of the boiler — has either lost its stored settings, encountered a component-level failure, or is struggling to send and receive signals correctly. On C40 and C55 models, the manufacturer describes this as an internal electronics error requiring a reset or control box replacement. On the C36, E11 (alongside the closely related E10) points to a control box fault, though some C36 firmware versions may also associate E11 with an ignition failure — both ultimately trace back to the control electronics. The boiler will lock out and stop operating until the fault is resolved and a manual reset is performed.

Lockout — engineer likely May need a Gas Safe engineer 3 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Power-cycle the boiler DIY safe

    Switch the boiler off at the mains isolator or programmer and leave it off for at least 30 seconds. Turn it back on and allow it to complete its startup sequence. A brief power interruption can clear a transient electronic fault. If the E11 reappears immediately, move on to the next step rather than repeating this more than two or three times.

  2. Press the reset button DIY safe

    After a lockout, Keston boilers require a manual reset before they will attempt to fire again. Press and hold the reset button (usually marked with a flame or reset symbol on the front panel) for a few seconds. If the fault clears and the boiler runs normally, monitor it closely over the next day or two. If E11 returns, further investigation by an engineer is needed.

  3. Check for visible water leaks around the boiler DIY safe

    Look around the base of the boiler, the pipework connections, and inside the boiler casing if you can safely see in without removing panels. Any signs of dampness, corrosion staining, or dripping water should be noted and reported to your engineer. Do not attempt to repair a leak yourself — but flagging it early helps the engineer prioritise the correct fix and avoids spending money on a new PCB while a leak remains.

  4. Arrange a Gas Safe engineer visit for diagnostic testing Gas Safe engineer

    An engineer will use a multimeter to confirm whether the PCB is receiving the correct power supply and sending appropriate signals. They will also inspect all wiring harnesses and connectors for damage, corrosion, or loose terminals. This diagnostic work must be carried out by a Gas Safe registered engineer — do not attempt to open the boiler casing or touch any internal components yourself.

  5. Repair any identified leak before replacing the PCB Gas Safe engineer

    If a water leak is found during the engineer's inspection, it should be fixed first. Fitting a new control board into a boiler that still leaks is likely to result in the same E11 fault returning within months. Leak repairs typically involve replacing seals, a heat exchanger, or pipework joints — all Gas Safe work.

  6. PCB / control box replacement if required Gas Safe engineer

    Where the PCB is confirmed faulty and no underlying cause can be resolved, a full control board replacement is required. The engineer will source a compatible unit for your specific Keston model (C36, C40, or C55), fit and configure it, and carry out commissioning checks before returning the boiler to service. On older boilers, it is worth discussing with the engineer whether replacement of the entire boiler may be more cost-effective than a PCB at this stage.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£500, depending on the underlying cause.

Frequently asked questions

Can I fix the Keston E11 fault myself?

The only safe DIY actions are a power-cycle and a boiler reset. Everything beyond that — testing the PCB, inspecting internal wiring, repairing leaks, or replacing the control board — must be carried out by a Gas Safe registered engineer. Working on boiler electronics without the correct qualifications is unsafe and could invalidate your boiler warranty or home insurance.

How much does a Keston PCB replacement cost in the UK?

A full PCB replacement on a Keston boiler typically costs in the region of £400–£550 once parts and labour are included, with the board itself accounting for the majority of that figure. However, if the underlying problem turns out to be a wiring fault or a repairable component, your bill could be considerably lower — closer to £150–£250 for diagnosis and repair. Always ask the engineer to carry out a full diagnostic before committing to a new board.

My Keston C36 shows E11 — is it a PCB fault or an ignition fault?

On the C36, E11 is primarily listed as a control box error, but certain firmware versions of the C36 also associate E11 with ignition failure. In practice, an engineer will test both the PCB and the ignition circuit during their diagnosis. The two are related — ignition problems can produce signals the PCB cannot process, triggering an electronics fault code — so both systems will typically be checked at the same visit.

Is it worth repairing a Keston boiler with an E11 fault, or should I replace it?

This depends heavily on the boiler's age and service history. If the boiler is under 10 years old and has been regularly serviced, a PCB repair or replacement is usually worthwhile. On older Keston models — particularly the Qudos range — efficiency is significantly lower than modern alternatives, and a PCB replacement costing £400–£550 on top of an ageing boiler may not represent good value. Ask your engineer for an honest assessment before proceeding.

Affected models: Keston C36, Keston C40, Keston C55

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Keston E11 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →