What does the Keston E67 fault code mean?

The E67 code appears on Keston Qudos boilers when the system water pressure drops below 0.4 bar — the minimum threshold the boiler needs to operate safely. At this point the boiler locks out completely and will not restart on its own; you must resolve the pressure issue and then press the reset button to get it running again. Normal working pressure for a Keston system should sit between 1.0 and 1.5 bar, with around 1.2–1.3 bar being ideal. E67 is essentially the boiler's way of telling you there is not enough water in the sealed system to circulate safely.

Lockout — engineer likely Some DIY checks possible 1 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the pressure gauge on the boiler DIY safe

    Look at the pressure gauge — either a dial or a digital display. If it reads below 1.0 bar (or is showing near zero), low pressure is confirmed as the cause of E67. If the gauge reads above 1.0 bar, the fault may have a different underlying cause and you should contact an engineer.

  2. Top up the system pressure using the filling loop DIY safe

    Switch the boiler off and let it cool for at least 30 minutes — ideally an hour — before repressurising. Locate the filling loop, which is usually a braided flexible hose with two valves situated beneath the boiler. Slowly open both valves and watch the pressure gauge rise. Stop when it reaches approximately 1.2 bar (do not exceed 1.5 bar). Close both valves firmly, then disconnect and store the filling loop. If your Keston boiler has an integral (built-in) filling loop, follow the same principle using the designated valves.

  3. Reset the boiler DIY safe

    Press and hold the reset button on the boiler's control panel until the boiler attempts to fire. E67 will not clear automatically — the reset must be performed manually after the pressure has been restored. If the boiler does not restart after one or two reset attempts, do not continue pressing reset repeatedly.

  4. Monitor the pressure over the following days DIY safe

    Check the pressure gauge every day or two. If it holds steady around 1.0–1.5 bar and E67 does not return, the issue was a simple pressure drop and no further action is needed. If pressure falls again within days or weeks, there is an underlying problem — a leak, a faulty expansion vessel, or a weeping PRV — that needs professional attention.

  5. Check the PRV discharge pipe for dripping water DIY safe

    Find the small-diameter pipe that exits the boiler and terminates outside (often through an external wall, low down). If water is trickling or dripping from it, the PRV is releasing pressure — this suggests either the PRV itself is faulty or the expansion vessel is no longer absorbing pressure fluctuations correctly. Make a note of this to tell your engineer.

  6. Call a Gas Safe registered heating engineer Gas Safe engineer

    If pressure keeps dropping, if you cannot locate the filling loop, if the PRV discharge pipe is dripping, or if the boiler fails to stay running after a reset, contact a Gas Safe registered engineer. They will carry out a leak detection check, test the expansion vessel charge and replace it if needed, and assess the PRV. Do not attempt to open sealed system components, adjust the PRV, or carry out any internal boiler work yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£350, depending on the underlying cause.

Frequently asked questions

Can I repressurise my Keston boiler myself to clear E67?

Yes — topping up the system pressure via the filling loop is a straightforward homeowner task. Switch the boiler off, let it cool, then slowly open the filling loop valves until the gauge reads around 1.2 bar. Close the valves, then press reset. If the pressure holds and E67 does not return, you are done. However, if you cannot find the filling loop, if the pressure drops again quickly, or if you are unsure at any stage, call a Gas Safe engineer rather than guessing.

Why does my Keston boiler keep losing pressure and showing E67 again?

Recurring pressure loss after repressurising points to an underlying fault rather than a simple top-up issue. The most common culprits are a small leak somewhere in the pipework or radiator valves, a waterlogged expansion vessel that can no longer absorb pressure changes, or a pressure relief valve (PRV) that has started to weep. A Gas Safe engineer can carry out a leak detection check and test the expansion vessel charge to pinpoint the cause. Repeatedly topping up without fixing the root cause risks water damage to your property and boiler internals.

How much does it cost to fix a Keston E67 fault in the UK?

If the boiler simply needed repressurising, an engineer call-out for that alone typically costs £60–£100. A PRV replacement usually comes in around £100–£150 including labour. Expansion vessel replacement — the most common repair behind recurring E67 faults — typically costs £150–£350 all in, depending on the vessel size and access. If the expansion vessel and PRV both need replacing at the same time (which engineers often recommend when one has failed), expect to pay toward the upper end of that range. Leak repairs vary considerably depending on where the leak is located.

What pressure should my Keston boiler run at?

Keston recommends a cold system pressure of around 1.0 to 1.5 bar, with 1.2–1.3 bar being a good target when the system is cold. When the heating is running and the water is hot, pressure will naturally rise slightly — typically to around 1.5–2.0 bar — which is normal. If you see the pressure climbing above 2.5 bar or the PRV discharge pipe running with water, that suggests a different problem (often a failed expansion vessel) and you should call an engineer promptly.

Affected models: Keston Qudos

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Keston E67 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →