Navien E351 Fault Code: Causes, Fixes & Repair Costs

What does the Navien E351 fault code mean?

The E351 code appears on Navien combi boilers when the central heating circuit cannot reach or hold its target pressure within an acceptable timeframe. Specifically, the boiler monitors how long the built-in auto feeder valve stays open while attempting to top up the system. If that valve remains open for more than five minutes without the heating circuit reaching its required pressure — typically around 12–15 PSI (roughly 0.8–1.0 bar) when cold — the boiler shuts down and displays E351. This is distinct from the domestic hot water side, which runs at mains pressure; E351 concerns only the sealed heating circuit. The fault is the boiler's way of saying: 'I've been trying to refill the system for too long and something is stopping me from succeeding.'

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the boiler's pressure gauge and compare it with the display reading DIY safe

    Look at the physical pressure gauge on the front of the boiler. A cold heating system should normally sit between 1.0 and 1.5 bar (roughly 15–22 PSI). If the gauge shows normal pressure but the boiler is still displaying E351, this may indicate a faulty pressure sensor rather than a genuine pressure loss — note this down to tell your engineer. If the gauge shows low pressure (below 1.0 bar), move to the next step.

  2. Top up the system pressure using the filling loop if pressure is low DIY safe

    Locate the filling loop — usually a braided flexible hose or a built-in lever valve beneath the boiler. Slowly open the valve and allow pressure to rise to around 1.2–1.5 bar, then close the valve completely. Do not overfill; stop before 2.0 bar. If you cannot find the filling loop or are unsure how the system works, do not attempt this and contact an engineer instead.

  3. Reset the boiler (no more than 2–3 times) DIY safe

    Once pressure is at the correct level, press and hold the reset button as described in your Navien user manual. If the boiler fires up and runs normally, monitor the pressure over the next 24–48 hours. If pressure drops again within a short period, this strongly suggests a leak or a failed expansion vessel and you should not continue resetting — call an engineer.

  4. Inspect visible pipework, radiators, and the boiler casing for signs of water leaks DIY safe

    Walk around your home and look for damp patches near radiators, beneath the boiler, along visible pipe runs, and around radiator valves. Check for water stains or corrosion on pipework. If you spot any active dripping or persistent moisture, do not attempt to fix it yourself — note the location and report it to your engineer.

  5. Bleed radiators, starting from the highest floor and working downwards DIY safe

    If you suspect trapped air (for example, radiators feel cold at the top but warm at the bottom, or the system was recently drained), bleeding may help. Use a radiator bleed key to open the bleed valve on each radiator until water dribbles out steadily with no hissing air. Remember to check and re-top the system pressure afterwards, as bleeding releases a small amount of water.

  6. Check that the cold water supply isolating valve is fully open DIY safe

    Locate the isolating valve on the cold water feed pipe to the boiler — this is typically found on or near the boiler itself and will have a flat-head screw slot or a lever handle. Ensure it is fully open (lever in line with the pipe, or slot in line with the pipe for a screw type). If you are unsure which valve this is, do not operate any valves and let your engineer identify it.

  7. Call a Gas Safe registered engineer to diagnose and repair the underlying fault Gas Safe engineer

    If the fault persists after the homeowner checks above, or if pressure keeps dropping, a Gas Safe engineer is required. They will check the expansion vessel pre-charge pressure and replace the vessel if the membrane has failed, inspect internal boiler components including the heat exchanger for leaks, test and replace the auto feeder valve if stuck or malfunctioning, verify the pressure sensor and wiring harness, and carry out a full system pressure test to locate any hidden leaks. Do not repeatedly reset the boiler or ignore this fault — low pressure in a sealed system can affect boiler safety and efficiency.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£400, depending on the underlying cause.

Frequently asked questions

Can I just keep resetting the Navien E351 and topping up the pressure myself?

You can reset the boiler and top up the pressure once or twice as an initial check, but you should not make a habit of it. If the pressure keeps dropping and E351 keeps returning, there is an underlying problem — most likely a leak or a failed expansion vessel — that will not resolve itself. Repeatedly resetting while ignoring the root cause risks further damage and in the case of a leak, water damage to your property. Treat recurring E351 as a sign to book an engineer promptly.

How much does it cost to fix Navien E351 in the UK?

For the most common causes, most homeowners pay between £150 and £400 all in. An expansion vessel replacement typically costs £200–£350 including labour, while a faulty auto feeder valve or pressure sensor usually comes in at £150–£280. If the fault turns out to be a heat exchanger leak or a PCB failure, costs can rise to £400–£600 or more — at that level it is worth comparing the repair cost against a new boiler, particularly if your Navien is over ten years old.

Why does the Navien E351 fault relate to the expansion vessel so often?

Navien's own technical data indicates that expansion vessel failure accounts for a large proportion of E351 faults. The expansion vessel contains a pressurised air chamber separated from the heating water by a rubber membrane. Over time the membrane degrades or the pre-charge air pressure drops, meaning the vessel can no longer absorb the normal pressure changes as the system heats and cools. This causes the system pressure to swing unpredictably, prompting the auto feeder to activate repeatedly and eventually time out. Expansion vessels have a typical lifespan of 8–12 years and are one of the more commonly replaced components on maturing boiler systems.

Is E351 dangerous — should I stop using my boiler immediately?

E351 is a lockout code, meaning the boiler has already shut itself down as a precaution, so the immediate safety risk is low. However, you should not simply force it back into operation and ignore the fault. If the cause is a water leak inside the boiler, continued operation could worsen the leak or damage electrical components. If you can see any active dripping from the boiler or pipes, turn the boiler off at the mains and call an engineer without delay. If there is no visible leak and the boiler runs normally after a single reset and pressure top-up, it is reasonable to use it while awaiting an engineer appointment — but monitor the pressure daily.

Affected models: Navien NCB-240E, Navien NCB Series, Navien NFC-175, Navien NFC Series, Navien NCB-H Series

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Navien E351 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →