Navien E352 Fault Code: Causes, Fixes & Repair Costs

What does the Navien E352 fault code mean?

The E352 fault code on Navien boilers signals that the system has detected excessively high water pressure. Specifically, the boiler's water pressure sensor has registered a reading of approximately 3.9 bar (around 56.6 PSI) or above for at least three consecutive seconds, prompting an automatic shutdown to protect the system. The fault will clear itself automatically once pressure falls back to around 3.0 bar (43.5 PSI) or below. This is a safety-driven lockout — the boiler is doing its job by refusing to operate under potentially damaging conditions.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge DIY safe

    Look at the pressure gauge on the front of the boiler or on the pipework nearby. Normal operating pressure for a Navien boiler is between 1.0 and 2.0 bar when the system is cold. If the gauge reads significantly above 2.0 bar — and especially if it is approaching or above 3.0 bar — you have confirmed the system is overpressurised. Note the reading before doing anything else.

  2. Check whether the filling loop is open or leaking DIY safe

    Locate the filling loop — usually a flexible braided hose with one or two valves connecting the cold mains supply to the heating pipework. Both valve handles should be perpendicular to the pipe (closed position). If either handle is in line with the pipe, it is open and allowing water in. Close both valves fully and monitor whether pressure continues to rise. If the loop has been disconnected after use, confirm it is fully removed and capped.

  3. Attempt a boiler reset DIY safe

    On most Navien boilers, you can reset the fault by pressing the Back button on the front panel. If the boiler restarts and runs normally without the fault reappearing, monitor the pressure gauge over the next 30–60 minutes. If E352 returns quickly or repeatedly, do not continue resetting — repeated lockouts indicate an underlying issue that requires an engineer.

  4. Do not attempt to bleed pressure by opening valves or components Gas Safe engineer

    Releasing pressure from a heating system by opening drain cocks, bleed valves on the boiler body, or any internal component is not a safe DIY task on a system that may be at very high pressure. Scalding water or steam can be released suddenly. Leave any pressure reduction to a Gas Safe registered engineer who has the correct tools and training.

  5. Do not attempt to inspect or replace the expansion vessel, PRV, auto-fill valve, or pressure sensor Gas Safe engineer

    These components sit within the sealed heating system or involve pressurised connections. Testing the expansion vessel pre-charge, replacing a PRV, or verifying sensor output voltage all require specialist equipment and Gas Safe competency. Attempting these without the correct qualifications may also invalidate your Navien warranty.

  6. Call a Gas Safe registered engineer Gas Safe engineer

    If the boiler has locked out on E352, the most common repairs — expansion vessel recharge or replacement, PRV replacement, auto-fill valve repair, or pressure sensor replacement — all require a qualified engineer. When you call, mention the E352 code and describe what the pressure gauge shows. This will help the engineer arrive prepared with appropriate parts. You can verify an engineer's credentials at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£380, depending on the underlying cause.

Frequently asked questions

Can I fix a Navien E352 fault myself without calling an engineer?

There are a couple of safe checks you can do yourself: confirm the filling loop is fully closed, read the pressure gauge, and attempt a single reset using the Back button. However, if the boiler locks out again or the pressure remains above 2 bar, the underlying fix — whether that is recharging the expansion vessel, replacing the PRV, or swapping the pressure sensor — must be carried out by a Gas Safe registered engineer. Attempting internal system work yourself risks scalding injuries, voiding your Navien warranty, and potentially invalidating your home insurance.

Why does my Navien boiler keep showing E352 even after I reset it?

A fault that keeps returning after resetting almost always points to an ongoing condition rather than a one-off glitch. The most common culprits are a waterlogged expansion vessel that can no longer absorb pressure changes, a filling loop or auto-fill valve that is continuously admitting water, or a faulty pressure sensor generating false readings. Each of these requires professional diagnosis and repair — repeated resetting without addressing the root cause can mask a worsening problem and may eventually cause the PRV to discharge, which wastes water and can damage flooring or ceilings.

What pressure should my Navien boiler run at, and what triggers E352?

Navien boilers operate correctly at between 1.0 and 2.0 bar when the system is cold (cold fill pressure). As the system warms up, pressure naturally rises slightly — this is normal. The E352 fault is triggered when pressure reaches approximately 3.9 bar and holds there for three or more seconds. The fault clears automatically once pressure drops back to around 3.0 bar or below. If your gauge regularly climbs above 2.5 bar, you should have the expansion vessel inspected at your next service even if E352 has not yet appeared.

How much does it cost to fix a Navien E352 fault in the UK?

Most people with an E352 fault pay somewhere between £100 and £380 all-in. A pressure sensor swap or PRV replacement at the lower end of this range (£100–£200) is straightforward for an experienced engineer. Expansion vessel replacement — the most common root cause — typically costs £180–£350 depending on access and the vessel size required. In more complex cases where an internal heat exchanger has failed and is allowing mains water into the heating circuit, costs can rise considerably higher, but this is a rare outcome. Getting two or three quotes from Gas Safe registered engineers is always worthwhile.

Affected models: Navien NCB-180, Navien NCB-240, Navien NCB-300, Navien NCB-H series, Navien NPE series (combi models)

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Navien E352 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →