Nibe 2 Fault Code: Causes, Fixes & Repair Costs

What does the Nibe 2 fault code mean?

Alarm code 2 on Nibe heat pumps indicates that the BT2 sensor — which monitors the temperature of water returning from the heating circuit back into the heat pump — is either disconnected or has failed. Without a valid reading from this sensor, the unit cannot safely manage heating output, so both the main heating function and any supplementary electric backup heating are blocked until the fault is resolved.

Lockout — engineer likely 10 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Restart the heat pump from the controller DIY safe

    Switch the unit off from the controller or the dedicated isolator, wait around 30 seconds, then power it back on. A transient electrical disturbance can occasionally trigger a sensor alarm that clears itself once the system reinitialises. If the alarm does not return, monitor the unit over the next few hours to confirm normal operation.

  2. Reset the alarm via the controller menu DIY safe

    On Nibe controllers, an active alarm is indicated by a service-technician symbol in the display and a lit status indicator. Navigate to the alarm log in the menu and attempt a manual reset. If the underlying cause has been resolved — for example, a connector that reseated itself — the alarm will clear. If it returns immediately, the fault is still present.

  3. Check around the unit for obvious signs of cable damage DIY safe

    Without opening the unit's casing, take a visual look at any sensor cables that are visible at the exterior of the indoor unit. Look for chewed insulation, kinks, or cables that appear to have been pulled taut. Do not attempt to open the casing, move any wiring, or test electrical continuity yourself — this is purely a visual check to give a useful report to your engineer.

  4. Contact an MCS-certified Nibe engineer to inspect and test the BT2 sensor heat pump engineer

    An engineer will open the unit safely, locate the BT2 sensor at the heating return pipework, and check that the connector is fully seated at the control board. They will use a multimeter to measure the sensor's resistance against the expected NTC curve from the service manual. If the reading is outside tolerance, the sensor will be replaced. If the sensor tests fine, the engineer will trace the cable for breaks and, if necessary, test the relevant input channel on the PCB.

  5. Replace the BT2 sensor or repair the wiring as directed by the engineer's findings heat pump engineer

    Sensor replacement involves disconnecting the old sensor from its pipe pocket and the control board, fitting a correctly specified NTC replacement, and verifying the reading in the service menu before returning the unit to normal operation. Where the cable is damaged, the engineer may repair or re-route it. PCB replacement is only required if the board input is confirmed faulty after all other causes are excluded.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£350, depending on the underlying cause.

Frequently asked questions

Can my Nibe heat pump still provide hot water while alarm 2 is active?

It depends on your system setup, but in most cases alarm 2 blocks the heating function and supplementary heating while it is active. Hot water production via a separate DHW circuit may still operate if the relevant sensors are unaffected, but you should not rely on this. Check your controller display — if the hot water schedule is showing as blocked or the cylinder is not reaching temperature, treat it as a full system shutdown until the fault is cleared.

How long does it take to fix a BT2 sensor fault?

In most cases an engineer visit takes one to two hours. If the issue is simply a loose connector, the repair can be completed in the same visit once the engineer has the unit open. If a replacement sensor needs to be ordered, there may be a short wait — Nibe parts occasionally need to be shipped from stock, though many independent engineers carry common NTC sensors. Aim to get the fault attended to promptly, especially in cold weather, as backup heating is also blocked while alarm 2 is active.

Is alarm 2 on a Nibe heat pump an emergency?

It is not an immediate safety emergency in the way that a refrigerant leak or electrical fault would be, but it is a priority fault because it disables both your heating and any electric backup. In cold weather this can leave your home without heat relatively quickly. Contact an MCS-certified engineer promptly rather than leaving it for a routine appointment.

Could a faulty PCB cost more than the estimate shown?

Yes — if the sensor and wiring both test as healthy and the fault is traced to a failed input channel on the main control PCB, the board replacement cost can range from around £350 to over £600 for parts alone on some Nibe models, plus labour. However, PCB failure is the least common cause of alarm 2; the large majority of cases are resolved by a sensor or cable repair within the typical £150–£350 range shown above.

Affected models: Nibe F2040, Nibe F2120, Nibe S2125, Nibe F730, Nibe F1145, Nibe F1245, Nibe VVM 320, Nibe VVM 500, Nibe SMO 20, Nibe SMO 40

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Nibe 2 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →