Nibe 220 Fault Code: Causes, Fixes & Repair Costs

What does the Nibe 220 fault code mean?

Alarm 220 on a NIBE system is a high pressure alarm: the outdoor heat pump unit has sent a fault message to the indoor controller reporting that refrigerant pressure on the high side of its circuit went out of range, and the compressor is blocked in response. High-side pressure climbs when the heat being produced cannot be shed — most often because water flow through the condenser is restricted (clogged filter, airlock, pump or diverter trouble), occasionally because of refrigerant-circuit faults or a pressure switch problem. It appears on split and VVM-based systems where an indoor module supervises an outdoor unit, and it is the NIBE counterpart of the high-pressure lockouts every refrigeration circuit carries.

Stop & check now Some DIY checks possible 6 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Check system pressure and open heating zones DIY safe

    Confirm heating system pressure is in the normal band and zones/radiators are open — give the heat somewhere to go before resetting.

  2. Acknowledge the alarm once and observe DIY safe

    Reset/acknowledge the alarm on the indoor display a single time. If it returns, stop resetting — the outdoor unit is reporting a genuine condition and repetition only stresses the compressor.

  3. Have a suitably qualified heat pump engineer complete the documented checks heat pump engineer

    The engineer will verify flow rate against commissioning, clean the filter, test the pump and diverter valve, and — with the water side proven — investigate the refrigerant pressures and the switch itself. Any work on the sealed refrigerant circuit legally requires an F-Gas registered engineer; a NIBE-accredited (NIBE Pro) installer is the natural choice.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£450, depending on the underlying cause.

Frequently asked questions

What does alarm 220 mean on my NIBE?

The outdoor unit reported refrigerant pressure too high on the discharge side and the compressor is blocked. It usually means the heat could not be carried away — restricted water flow is the prime suspect. Check pressure and open zones, reset once; recurrence needs an engineer's flow and refrigerant checks.

It trips mostly when heating hot water — why?

Cylinder reheat is the hardest duty: highest temperatures, and everything hanging on the diverter valve directing full flow to the coil. Marginal flow or a lazy diverter shows up there first. Tell the engineer the pattern — it points the diagnosis.

Is repeated resetting harmful?

Yes — each reset restarts the compressor into the same over-pressure conditions. One reset to clear a transient is fine; beyond that you are wearing the most expensive component in the system against a known fault.

Affected models: Nibe VVM 225, Nibe VVM 320, Nibe VVM 500, Nibe F2040 (with VVM indoor module), Nibe F2120 (with VVM indoor module), Nibe AMS 10

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Nibe 220 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →