Nibe 222 Fault Code: Causes, Fixes & Repair Costs

What does the Nibe 222 fault code mean?

Alarm 222 on a NIBE system is a motor protection alarm: the outdoor unit has reported that its compressor motor protection operated — the device guarding the compressor against overcurrent, phase problems and overheating — and the compressor is blocked. Motor protection trips when the compressor works abnormally hard or its electrical supply misbehaves: seized or tight bearings, refrigerant conditions loading the motor (including liquid refrigerant returning to the compressor), voltage sags or phase loss, or the protection module itself failing. One reset after a possible supply blip is reasonable; a recurring 222 needs proper electrical and refrigerant-side diagnosis before the compressor pays the price.

Stop & check now 6 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Acknowledge the alarm once and observe DIY safe

    Reset/acknowledge the alarm on the indoor display a single time. If it returns, stop resetting — the outdoor unit is reporting a genuine condition and repetition only stresses the compressor.

  2. Have a suitably qualified heat pump engineer complete the documented checks heat pump engineer

    The engineer will measure the supply voltage and the compressor's actual running current, check the protection device and its wiring, and assess the refrigerant conditions the motor is working under — establishing whether the protection tripped honestly before any thought of overriding or replacing it. Any work on the sealed refrigerant circuit legally requires an F-Gas registered engineer; a NIBE-accredited (NIBE Pro) installer is the natural choice.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£700, depending on the underlying cause.

Frequently asked questions

What does alarm 222 mean on my NIBE?

The outdoor unit's compressor motor protection tripped — the device guarding the compressor from overcurrent and overheating — and the compressor is blocked. One reset after a possible power blip is fine; a recurring alarm needs the supply, the protection device and the compressor's real load professionally measured.

Is my compressor failing?

Not necessarily — supply problems and protection-module faults trip the same alarm. But because a genuinely labouring compressor is among the possibilities, recurring 222s deserve prompt diagnosis rather than repeated resets; the compressor is the one part you cannot afford to sacrifice to impatience.

The alarm coincides with evening peaks — meaningful?

Quite possibly — local voltage sags at peak demand load motors measurably harder. An engineer logging the supply voltage across an evening can confirm it, and persistent undervoltage is worth raising with your network operator.

Affected models: Nibe VVM 225, Nibe VVM 320, Nibe VVM 500, Nibe F2040 (with VVM indoor module), Nibe F2120 (with VVM indoor module), Nibe AMS 10

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Nibe 222 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →