Ravenheat E42 Fault Code: Causes, Fixes & Repair Costs

What does the Ravenheat E42 fault code mean?

E42 on a Ravenheat boiler belongs to the E42–E44 fault group, which Ravenheat's documentation describes as a 'different temperature' error — the control board is comparing readings from its temperature sensors (typically the flow and return NTC thermistors) and finding a difference or pattern that should not be possible if water were circulating properly and both sensors were healthy. Rather than keep firing on readings it cannot reconcile, the board stops the boiler and displays the code. In practice E42 comes down to one of two things: a sensor (or its wiring) drifting out of specification, or a genuine circulation problem — a struggling pump, air in the system or a blockage — making the real temperatures diverge abnormally.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 3 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge DIY safe

    Low pressure worsens circulation and sensor disagreement. If the gauge is below 1 bar, top up slowly to around 1.2 bar using the filling loop, then reset once.

  2. Bleed the radiators DIY safe

    If radiators are cold at the top or the system has recently been refilled, bleed the air out with a radiator key, re-check pressure afterwards, and try one reset.

  3. Reset once and observe DIY safe

    Reset the boiler a single time and watch it run. If E42 returns within minutes, stop resetting — a drifting sensor or circulation fault will not clear itself.

  4. Have an engineer test the sensors and circulation Gas Safe engineer

    A Gas Safe registered engineer will measure both NTC sensors against the specification table, inspect the wiring, and check the pump and system flow. The usual outcome is a replacement sensor or attention to the pump/system, after which the readings reconcile and the code clears.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£300, depending on the underlying cause.

Frequently asked questions

What does E42 mean on a Ravenheat boiler?

It is part of Ravenheat's E42–E44 'different temperature' group: the board has compared its temperature sensor readings and found a difference it cannot reconcile. That points either at a faulty/drifting sensor (or its wiring) or at a genuine circulation problem such as a struggling pump or air in the system.

Can I fix E42 myself?

You can do the safe basics: top the pressure up to around 1.2 bar if it is low, bleed the radiators, and reset once. If the code returns, the diagnosis — testing sensors against their resistance table and checking the pump — needs a Gas Safe registered engineer.

How is E42 different from E43 and E44?

They are siblings in the same comparison-fault family; the specific code reflects which check tripped. The practical diagnosis is the same across all three: verify the sensors and their wiring, then verify circulation.

Affected models: Ravenheat RSF, Ravenheat CSI, Ravenheat LS Series

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ravenheat E42 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →