Remeha A.03.17 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha A.03.17 fault code mean?

The A.03.17 code appears on Remeha boilers that use the structured alphanumeric fault code system — most notably the Quinta Ace range and similar newer Remeha models. The 'A' prefix denotes a Warning rather than a full blockage or lockout, meaning the boiler has detected a developing problem but is still attempting to operate. The '03' group relates to the water pressure and flow subsystem, and '.17' is the specific sub-fault indicating that system pressure has dropped towards or below the safe minimum threshold. In plain terms, the boiler's pressure sensor is telling you the water pressure is too low and, if left unaddressed, the warning will escalate to a blocking ('H') or lockout ('E') code, causing the boiler to shut down entirely. Act on this warning promptly — it is the system giving you an early chance to resolve the issue before a full breakdown occurs.

Engineer may be needed Some DIY checks possible May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge DIY safe

    Locate the pressure gauge on the boiler — on most Remeha models it is visible on the front panel or display. A healthy reading is between 1 and 2 bar when the system is cold. If the needle or digital reading is below 1 bar, low pressure is almost certainly the cause of the A.03.17 warning.

  2. Repressurise via the filling loop if pressure is below 1 bar DIY safe

    Find the filling loop — usually a braided flexible hose with one or two valves beneath or near the boiler. Slowly open the valve(s) and watch the pressure gauge rise. Stop when the pressure reaches approximately 1.5 bar. Close the valve(s) securely. Never overfill beyond 2 bar. If you are unsure how to locate the filling loop on your specific model, consult the user manual or call Remeha technical support on 0330 678 0140.

  3. Inspect the system for visible leaks DIY safe

    Walk around the property and check all accessible radiators, towel rails, pipe joints, and the area immediately around the boiler for signs of moisture, damp patches, rust staining, or dripping water. Pay close attention to radiator valve connections and any recent plumbing work. If you find an active leak, do not simply keep topping up the pressure — the leak must be repaired.

  4. Clean the boiler water filter DIY safe

    If pressure is adequate but the warning persists, locate the in-line water filter on the boiler's return pipework. Turn off the boiler and isolate the relevant section of pipework before carefully removing the filter cartridge. Rinse it under warm running water to clear any sediment or debris, then refit securely. Check the manufacturer guidance in your installation manual for the correct isolation procedure for your specific model.

  5. Reset the boiler DIY safe

    Once you have repressurised the system and checked for leaks, attempt a boiler reset. Turn the boiler off, wait approximately 30 seconds, then switch it back on — or use the dedicated reset button if your model has one. If the A.03.17 warning clears and does not return within a day or two, the issue was likely a straightforward low-pressure event. If the warning returns repeatedly, there is an underlying fault that needs professional attention.

  6. Have a Gas Safe engineer inspect the pressure sensor and safety valve Gas Safe engineer

    If the system pressure is correct but the warning persists, a Gas Safe registered engineer should test the pressure sensor to confirm it is reading accurately and check the safety relief valve is not weeping or discharging. A faulty sensor giving a false low reading will need to be replaced — this is not a homeowner task.

  7. Have a Gas Safe engineer test and service the circulation pump Gas Safe engineer

    If there are signs of poor circulation — for example, some radiators staying cold, or the boiler cycling on and off rapidly — a Gas Safe or suitably qualified heating engineer should inspect the pump. They can test whether it is running correctly, check its wiring and speed settings, and replace it if it has failed. Pump replacement on commercial-scale units such as the Quinta Ace is a job for a professional.

  8. Call a Gas Safe registered engineer if the fault persists or you are unsure Gas Safe engineer

    If the A.03.17 warning keeps returning after repressurisation, if you cannot identify the cause, or if any of the above checks are beyond what you are comfortable doing, contact a Gas Safe registered engineer. The warning will escalate to a blocking or lockout fault if ignored, leaving you without heating or hot water. You can verify an engineer's Gas Safe registration at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£400, depending on the underlying cause.

Frequently asked questions

Is the Remeha A.03.17 a lockout — will my boiler have stopped working?

No, not immediately. The 'A' prefix in A.03.17 stands for Warning in Remeha's fault code hierarchy, which sits below 'H' (Blocking) and 'E' (Lockout). At the warning stage the boiler is still attempting to operate but is alerting you to a pressure problem that needs attention. If the underlying cause is not resolved, the boiler will typically escalate to a blocking or lockout code and shut down completely, so it is important to act promptly rather than ignoring the warning.

How often should I check the pressure on a Remeha Quinta Ace?

A quick monthly check is a good habit. The pressure should sit between 1 and 2 bar when the system is cold, with 1.5 bar being the typical target. If you find yourself topping up the pressure more than once every few months, there is likely a slow leak somewhere in the system that should be investigated by a heating engineer rather than simply repressurising repeatedly.

My Remeha keeps losing pressure and showing A.03.17 — what does that mean?

Recurring pressure loss that keeps triggering the A.03.17 warning almost always points to a leak in the system. This could be a weeping radiator valve, a pinhole in pipework, a leaking pump seal, or a faulty pressure relief valve that is discharging water. Topping up the pressure will clear the warning temporarily but will not fix the root cause. A Gas Safe registered engineer should trace and repair the leak. Left unresolved, persistent pressure loss can cause corrosion damage and eventually a more serious breakdown.

Could the A.03.17 warning mean I need a new heat exchanger or PCB?

It is very unlikely. The A.03.17 code specifically relates to water pressure, so in the vast majority of cases the repair involves repressurising the system, fixing a leak, replacing a pressure sensor, or servicing the pump — all relatively modest costs typically in the £100–£400 range. A heat exchanger or PCB replacement would only become relevant if sludge damage or an electrical fault were discovered during investigation of the underlying pressure problem, and these scenarios are uncommon. If an engineer quotes for either component purely on the basis of this code, it is worth seeking a second opinion.

Affected models: Remeha Quinta Ace, Remeha Quinta Ace 45, Remeha Quinta Ace 65, Remeha Quinta Ace 90, Remeha Quinta Ace 115, Remeha Calenta, Remeha Gas 210 Eco

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha A.03.17 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →