Remeha E.00.40 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha E.00.40 fault code mean?

The E.00.40 fault code on a Remeha boiler indicates that the hydraulic pressure sensor is reporting a reading that falls below its expected minimum threshold, or that the sensor is not responding at all. In plain terms, the boiler cannot confirm that adequate water pressure exists within the system. To protect itself from running dry or overheating, the boiler locks out and halts operation until the underlying cause is identified and resolved. This fault is most commonly seen on the Remeha Quinta Ace range and can stem from genuinely low system pressure, a blocked water filter restricting flow, or a faulty pressure sensor.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge DIY safe

    Look at the pressure gauge on the boiler's display or on the pipework. It should read between 1 and 2 bar when the system is cold. If the needle sits below 1 bar or the display shows a very low figure, low pressure is almost certainly responsible for the E.00.40 fault.

  2. Repressurise the boiler using the filling loop DIY safe

    Switch the boiler off and allow it to cool below 40°C. Open all radiator valves fully. Slowly open the filling loop valve — usually a small lever or tap on the pipework beneath the boiler — while watching the pressure gauge. Once the reading reaches approximately 1 to 1.5 bar, close the filling loop valve firmly. Switch the boiler back on and reset the fault. If pressure rises normally but drops again within a few days, there is likely a leak in the system that needs a Gas Safe engineer to investigate.

  3. Reset the boiler DIY safe

    After repressurising, press and hold the reset button as described in your Remeha boiler's user guide. Allow the boiler to complete its ignition sequence. If the E.00.40 code returns immediately, do not keep resetting repeatedly — move on to the next checks or call an engineer.

  4. Inspect for visible leaks around the boiler and pipework DIY safe

    Check around radiator valves, visible pipework joints, and underneath the boiler for signs of dripping water or damp patches. Even a slow weep can cause pressure to drop gradually. Do not attempt to tighten gas connections yourself, but tightening a dripping radiator valve tail or bleed screw is a straightforward homeowner task.

  5. Check that all system valves are fully open DIY safe

    Ensure all lockshield and thermostatic radiator valves are fully open, and that any isolating valves on the boiler's flow and return pipework are in the open position. Partially closed valves can restrict flow and contribute to pressure-related faults.

  6. Inspect and clean the water filter (engineer task on sealed systems) Gas Safe engineer

    The Remeha Quinta Ace has an inline water filter that can become clogged with system debris. Cleaning it involves isolating the boiler and draining a section of the hydraulic circuit. This should be carried out by a Gas Safe registered engineer who can also check the heat exchanger cleanliness and ensure the system is properly de-aired at the same time.

  7. Have the pressure sensor tested and replaced if faulty Gas Safe engineer

    If system pressure and filter condition are both confirmed as satisfactory but the E.00.40 fault persists, the hydraulic pressure sensor itself is likely defective. A Gas Safe registered engineer will test the sensor's electrical output, check its wiring harness, and replace the sensor if required. The engineer should also inspect the safety relief valve operation during the same visit.

  8. Call a Gas Safe registered engineer Gas Safe engineer

    If the fault code returns after repressurising, or if you are unable to identify an obvious cause, contact a Gas Safe registered engineer. They can carry out a full system diagnosis, check the heat exchanger, test the sensor, and safely resolve any underlying leak or component failure. Always verify an engineer's Gas Safe registration at gassaferegister.co.uk before booking.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£320, depending on the underlying cause.

Frequently asked questions

Can I fix the Remeha E.00.40 fault myself without calling an engineer?

The most common cause — low system pressure — is something you can resolve yourself by repressurising via the filling loop. That costs nothing if you do it yourself, or just a call-out fee if an engineer does it. However, if the pressure keeps dropping, the filter needs cleaning, or the sensor needs replacing, a Gas Safe registered engineer is required. Attempting internal boiler work without Gas Safe registration is illegal and potentially dangerous.

How much does it typically cost to fix the E.00.40 fault in the UK?

For most households, the repair falls between £120 and £320 including parts and labour. A simple pressure sensor replacement with a standard call-out will sit at the lower end of that range. If the engineer also needs to clean the heat exchanger, power flush the system, or address a hidden leak, costs move towards the higher end. Note that labour rates in London and the South East tend to run 20–40% above the UK average. In rare cases where the fault has caused damage to other components such as the PCB, costs can be higher — but that is uncommon for this particular code.

Why does my Remeha boiler keep losing pressure and showing E.00.40?

Recurring pressure loss nearly always points to a leak somewhere in the system — this could be a weeping radiator valve, a dripping joint, a failing pressure relief valve, or, less commonly, a micro-leak within the boiler itself. Repeatedly topping up the pressure without finding the source is not a safe long-term fix, as it gradually dilutes the system inhibitor and can lead to corrosion. Book a Gas Safe engineer to pressure-test the system and locate the source of the loss.

How do I prevent the E.00.40 fault from coming back?

Annual boiler servicing by a Gas Safe engineer is the single most effective preventative measure — it includes checking system pressure, inspecting the water filter, and testing sensor operation. Between services, keep an eye on the pressure gauge and top up if it dips below 1 bar. Make sure the system contains an appropriate dose of corrosion inhibitor, and avoid introducing any chemicals or solvents near the boiler's hydraulic components.

Affected models: Remeha Quinta Ace, Remeha Quinta Ace 30c, Remeha Quinta Ace 45c, Remeha Quinta Ace 65c, Remeha Quinta Ace 90c, Remeha Quinta Ace 115, Remeha Quinta Ace 135

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha E.00.40 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →