Remeha E.00.41 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha E.00.41 fault code mean?

The E.00.41 code appears on Remeha Quinta-series boilers (including the Quinta Ace and Quinta Pro) when the control system detects that the heating flow temperature has climbed faster than the permitted safe limit. Rather than risk overheating the heat exchanger or pipework, the boiler cuts out as a protective measure. On first occurrence the boiler will pause for around ten minutes and attempt to restart automatically; if the same condition is detected across five consecutive restart attempts, the boiler locks out fully and displays E.00.41 as a persistent fault requiring a manual reset. The E.00.4x block of codes as a whole covers water flow and temperature protection: E.00.40 relates to a flow or pressure sensor reading below its expected range, while E.00.41 specifically flags the excessive rate of temperature rise — essentially the boiler saying the heat it is generating cannot be carried away quickly enough by the circulating water.

Lockout — engineer likely May need a Gas Safe engineer 3 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge DIY safe

    Look at the pressure gauge on the boiler — it should read between 1 and 1.5 bar when the system is cold. If it has dropped below 1 bar, top up the system using the filling loop (usually a flexible braided hose with one or two isolation valves beneath the boiler). Open the valves slowly until the gauge reads around 1.2 bar, then close them. Do not overfill above 2 bar.

  2. Bleed radiators to release trapped air DIY safe

    Starting with the radiator furthest from the boiler, use a radiator bleed key to open each bleed valve slightly. Hold a cloth underneath and wait until a steady stream of water (not air or sputtering) emerges, then close the valve. Work back towards the boiler. Re-check system pressure afterwards and top up again if it has dropped.

  3. Check the boiler water filter for debris DIY safe

    Many Quinta installations include an in-line magnetic filter or dirt separator. Check whether it requires cleaning — a heavily blocked filter will visibly restrict flow. Isolating and removing the filter canister for a rinse is generally a straightforward homeowner task on most installations, but only do this if you are confident and the system is cool. If in doubt, leave it for the engineer.

  4. Verify that all system valves are fully open DIY safe

    Walk around the system and confirm that all lockshield valves on radiators, and any zone valves or motorised valves, are in the open or auto position. A single closed valve on a small circuit can be enough to restrict flow and trigger this code.

  5. Reset the boiler and observe DIY safe

    Once you have carried out the pressure, bleeding, and valve checks, reset the boiler using the reset button on the control panel. Allow it to complete a full heating cycle and watch whether the fault returns. Do not reset more than two or three times in quick succession — repeated resets without resolving the underlying cause can mask the problem and potentially cause further damage.

  6. Inspect and test the circulating pump — Gas Safe engineer required Gas Safe engineer

    An engineer will check whether the pump is energised and running at the correct speed setting. A seized pump can sometimes be freed by carefully turning the spindle, but if the pump is electrically faulty or has failed mechanically it must be replaced. This is not a job for an unqualified person, as it involves draining part of the system and working on electrical components within the boiler.

  7. Test the flow and return temperature sensors — Gas Safe engineer required Gas Safe engineer

    The engineer will use a multimeter to check the resistance of both NTC sensors against the expected values at a known water temperature. Loose or corroded connectors will also be inspected. A faulty sensor is straightforward and relatively inexpensive to replace, but accessing it correctly and verifying the reading requires proper diagnostic tools.

  8. Review boiler output and commissioning parameters — Gas Safe engineer required Gas Safe engineer

    On Quinta-series boilers the maximum output, pump speed, and temperature rise parameters are set in the service menu. An engineer can verify that these were set correctly during commissioning and adjust them if the boiler has been incorrectly configured for the connected system.

  9. PCB diagnosis and replacement if required — Gas Safe engineer required Gas Safe engineer

    If all physical components test as serviceable, the engineer may carry out further electronic diagnostics on the PCB. A board replacement is a last-resort step and must be carried out by a qualified engineer using a genuine Remeha-compatible part.

  10. Call a Gas Safe registered engineer Gas Safe engineer

    If the E.00.41 fault persists after you have checked the pressure, bled the radiators, and confirmed all valves are open, the fault requires professional diagnosis. Book a Gas Safe registered engineer who has experience with Remeha commercial or semi-commercial equipment — Quinta-series boilers are common in light commercial and larger domestic settings and not all domestic heating engineers will be familiar with them.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Can I reset a Remeha E.00.41 fault myself?

Yes, a manual reset is safe to attempt. Press and hold the reset button on the boiler's control panel until the fault clears, then allow the boiler to complete a full heating cycle. If the fault returns within a short period, do not keep resetting — it means an underlying problem needs professional attention. Repeated resets without a fix can mask the fault and won't address whatever is causing the temperature to rise too quickly.

What is the difference between Remeha fault codes E.00.40 and E.00.41?

Both codes sit within the same E.00.4x overheating and flow protection group on Quinta-series boilers. E.00.40 indicates that a flow or water pressure sensor has dropped below its expected minimum reading, suggesting insufficient water in the system. E.00.41 moves one step further and flags that the rate at which the flow temperature is rising has exceeded the permitted limit — meaning the boiler is generating heat faster than the circulating water can carry it away. The two codes share several common causes (low pressure, poor circulation) but E.00.41 can also point more specifically to a pump or flow restriction issue.

How much does it typically cost to repair a Remeha E.00.41 fault in the UK?

Most people with this fault pay somewhere between £120 and £380 all-in, depending on what is found. A pump service or sensor replacement at the lower end, or a pump replacement with a full system flush at the upper end, covers the majority of cases. Call-out and diagnosis alone typically runs £60–£100 for an independent Gas Safe engineer. If the PCB turns out to be the cause, the board itself can cost £200–£350 for a Remeha Quinta-compatible part on top of labour, which would push the total higher — worth bearing in mind if the boiler is already ageing.

Why does E.00.41 keep coming back on my Remeha Quinta?

A recurring E.00.41 usually means the root cause has not yet been identified and fixed. The most common culprits for a repeat fault are a circulating pump that is running but not at full capacity (a worn pump can limp along for months before failing completely), a partially blocked system filter, or creeping air returning to the system through a micro-leak. If the fault has returned more than twice after a reset, it is worth booking an engineer for a full flow-rate check and system pressure test rather than continuing to reset and hope.

Affected models: Remeha Quinta Ace, Remeha Quinta Pro, Remeha Quinta 115

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha E.00.41 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →