Remeha H.00.16 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha H.00.16 fault code mean?

H.00.16 is a temporary blocking fault on Remeha e-Smart boilers (Tzerra Ace, Quinta Ace, Gas 320/620 Ace and similar ranges). The 'H' prefix means the boiler has halted operation as a precaution but has not permanently locked out — it may self-recover or can be manually reset. Group '00' covers core control and sensing parameters, and sub-code '16' points specifically to a flame detection or ionisation signal anomaly: the control board has either detected an unexpected ionisation signal when the burner should be off (sometimes called a 'ghost flame'), or it has registered an ionisation signal inconsistency during or immediately after a burner firing cycle. Because any unintended flame condition is a safety concern, the boiler shuts down until the issue is resolved. Note that the permanent lockout equivalent of this fault is E.00.16 — if your display shows that code instead, the boiler requires a manual reset after the underlying problem is fixed.

Engineer may be needed May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Attempt a single boiler reset DIY safe

    Locate the reset button on the boiler's front panel (refer to your user guide if unsure). Press and hold as directed, then wait about 60 seconds to see if the boiler fires successfully. If it returns the H.00.16 code immediately or after one or two firing attempts, do not keep resetting — repeated resets without identifying the cause can mask a developing problem.

  2. Check the system pressure DIY safe

    Look at the pressure gauge on the boiler fascia. It should read between 1.0 and 1.5 bar when the system is cold. If it has dropped below 1 bar, top up via the filling loop following your boiler's user guide, then attempt one further reset. Low pressure alone is unlikely to cause this specific code, but it is worth ruling out before calling an engineer.

  3. Inspect the external flue terminal DIY safe

    Go outside and visually check the flue outlet and air intake terminal for obvious obstructions — debris, bird nesting material, or ice in cold weather. Do not attempt to dismantle any flue components; simply clear any external blockage you can reach safely from ground level. If the terminal looks clear, the issue is internal and requires an engineer.

  4. Engineer: inspect and test the ionisation/ignition electrode Gas Safe engineer

    A Gas Safe registered engineer should remove the electrode assembly, check the ceramic insulator for cracks, measure the electrode gap, and test the ionisation current under live firing conditions. A reading outside the 3–9 µA range indicates the electrode needs cleaning or replacement. The electrode itself is a relatively low-cost part (typically £15–£30), making this the first physical component to address.

  5. Engineer: check CO₂ combustion settings and gas valve operation Gas Safe engineer

    Incorrect CO₂ levels at the gas valve affect combustion quality and can destabilise the flame enough to produce erratic ionisation readings. The engineer should verify combustion analysis figures, check the gas valve actuator and seating for signs of leaking-by, and confirm adequate gas pressure and flow rate at full load. Any gas valve work is strictly Gas Safe only.

  6. Engineer: test the wiring loom and PCB Gas Safe engineer

    Using a multimeter, the engineer should check continuity and signal integrity on the wiring between the electrode and the PCB. If wiring checks out, the PCB's ionisation detection circuit should be tested. Depending on the findings, the PCB may be repairable by a specialist, which is generally more cost-effective than a straight replacement.

  7. Engineer: inspect the flue system for recirculation Gas Safe engineer

    If no component fault is found, the engineer should carry out a full flue integrity check — looking for incorrect terminal positioning, gaps in the flue run, or signs that combustion gases are being recirculated into the air supply. Flue modifications must comply with current Gas Safe and Building Regulations requirements.

  8. Call a Gas Safe registered engineer if the fault persists Gas Safe engineer

    If the boiler continues to display H.00.16 after a reset and your basic checks reveal nothing obvious, contact a Gas Safe registered engineer. Provide them with the full code, your boiler model, and any pattern you have noticed (e.g. only faults on ignition, or only after the boiler has been running a while). You can verify any engineer's registration at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Can I just keep resetting the boiler to clear H.00.16?

You can try one or two resets — the 'H' blocking code may clear itself if the fault was a momentary signal glitch. However, if the code returns each time the boiler attempts to fire, repeated resets will not fix the underlying problem and could mask a developing fault. Stop resetting after two or three attempts and arrange for a Gas Safe engineer to diagnose the root cause.

What is the difference between H.00.16 and E.00.16?

Both codes point to the same ionisation or flame signal fault, but the prefix tells you how serious it is. An 'H' code is a temporary blocking fault — the boiler has paused and may recover on its own or after a reset. An 'E' code is a permanent lockout, meaning the boiler will not restart at all until a Gas Safe engineer investigates and manually resets the unit. If your display has changed from H.00.16 to E.00.16, the fault has escalated and engineer attendance is now urgent.

My Remeha boiler is still under warranty — will this repair be covered?

Remeha (now marketed as Remeha by Baxi) offers a standard 2-year warranty on commissioned products and a 5-year warranty on the heat exchanger. If your boiler is within its warranty period, contact Remeha's customer support or your installing engineer before arranging an independent repair, as unauthorised work may affect your warranty. A warranty claim could mean the repair costs you nothing.

Could a PCB replacement be the answer, and how much does it cost?

A faulty PCB is a possible but less common cause of H.00.16 — engineers will typically test and replace the electrode and check the gas valve first, as these are cheaper and more frequently at fault. If the PCB does need replacing, the part alone typically costs £280–£380 for Remeha Ace-series boards, plus £100–£150 in labour. Some independent PCB repair specialists can refurbish the board for considerably less. If the PCB replacement cost approaches the value of an older boiler, it may be worth obtaining a new boiler quote for comparison.

Affected models: Remeha Tzerra Ace, Remeha Quinta Ace, Remeha Gas 320 Ace, Remeha Gas 620 Ace, Remeha Calenta Ace

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha H.00.16 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →