Remeha H.01.00 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha H.01.00 fault code mean?

The H.01.00 code on a Remeha boiler is a blocking fault labelled 'Comm Error', indicating that the boiler's internal electronics have lost communication between key components — typically between the main PCB and the control panel or display board. Unlike a full lockout (E-prefix codes), a blocking fault (H-prefix) means the boiler has halted as a safety precaution but has not permanently shut down; it may attempt to restart on its own or after a reset. The fault can stem from a loose connector, damaged wiring on the communications bus, a misconfigured parameter, or a failed PCB or control panel. A single reset is always worth trying first — a momentary power glitch can trigger this code — but if the fault returns the boiler needs hands-on attention from a Gas Safe registered engineer.

Engineer may be needed May need a Gas Safe engineer 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once using the front-panel reset button DIY safe

    Press and hold the reset button as described in your boiler's user guide, then wait at least 60 seconds to see whether the boiler fires up normally. A transient power blip can trigger H.01.00 and a single reset often clears it. Do not reset more than two or three times in quick succession — repeated failed restarts will not fix an underlying fault and may make diagnosis harder.

  2. Check the basics: mains power, gas supply, and system pressure DIY safe

    Confirm the boiler has a stable mains supply and that no other appliances in the property have lost power. Check that the gas supply is turned on at the meter and that other gas appliances work. Verify the boiler's system pressure is within the normal operating range (typically 1–1.5 bar when cold on a sealed system); top up via the filling loop if it has dropped below 1 bar. None of these checks will cause H.01.00 directly, but ruling them out ensures you are not missing a simpler problem.

  3. Note the exact code displayed and check for any related sub-codes DIY safe

    Write down the full fault code as shown on the display — on Remeha boilers a blocking fault is shown with an H prefix (e.g. H.01.00). If the display is cycling through multiple codes such as H.00.36, H.00.37, H.01.06, or H.01.07 alongside H.01.00, make a note of all of them. This information is invaluable for the engineer and for any call to Remeha technical support.

  4. Have a Gas Safe engineer inspect the communications bus wiring and connectors Gas Safe engineer

    An engineer will open the boiler casing and check the wiring harness and all connectors associated with the PCB communications circuit. In particular, connector X021 between the control panel and the main PCB must be firmly seated on all five pins with no signs of corrosion, heat damage, or cracking. Any loose, damaged, or corroded connector should be reseated or replaced. This is the most common physical cause of H.01.00 and is often resolved quickly.

  5. Have the engineer check and verify PCB detection and configuration parameters Gas Safe engineer

    If the wiring is sound, the engineer will use Remeha's service software or the boiler's built-in diagnostics to confirm that the main PCB is being correctly detected. If not, the PCB may need to be reseated in its housing or re-registered in the boiler's memory. The engineer will also review the configuration parameters to identify any corrupted or unknown values, restoring correct settings where needed.

  6. Replace the PCB or control panel if a component has failed Gas Safe engineer

    If diagnostics confirm that the main PCB or the control panel module is defective, the faulty component will need to be replaced with a genuine Remeha-approved part. The engineer will source the correct part for your specific model and carry out the swap, followed by recommissioning and a functional test to confirm communication is fully restored.

  7. If the fault persists or you are in any doubt, call a Gas Safe registered engineer Gas Safe engineer

    All work on the boiler's internal wiring, PCB, gas valve, and associated electronics must be carried out by a Gas Safe registered engineer. Do not attempt to open the boiler casing, handle circuit boards, or adjust any internal components yourself. If you have already tried a single reset and the H.01.00 code has returned, stop resetting and book an engineer — continued attempts will not resolve a hardware fault.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£400, depending on the underlying cause.

Frequently asked questions

Is the Remeha H.01.00 a lockout fault or can the boiler restart on its own?

H.01.00 is a blocking fault, not a full lockout. On Remeha boilers, codes starting with H indicate the boiler has paused as a precaution rather than permanently shut down. This means it may attempt to restart automatically once the underlying problem clears, or it will restart after a manual reset. A code starting with E (for example E.01.xx) would be a true lockout requiring an engineer to reset. That said, if H.01.00 keeps coming back after resets it needs professional attention — repeated self-resetting will not cure a wiring or PCB fault.

Can I fix a Remeha H.01.00 Comm Error myself?

The only safe DIY steps are pressing the reset button once, confirming you have mains power and gas supply, and topping up the system pressure if it has dropped. Everything else — inspecting the PCB connectors, reseating the communications bus wiring, adjusting configuration parameters, or replacing components — must be done by a Gas Safe registered engineer. The boiler's internal wiring and circuit boards carry mains voltage and are closely integrated with gas-connected components, so opening the casing without the right qualifications is both unsafe and potentially illegal.

How much does it typically cost to fix a Remeha H.01.00 fault?

If the cause is simply a loose or corroded connector on the communications bus, an engineer may be able to resolve it in a single visit for around £100–£180 including call-out and labour. If the main PCB or control panel module needs replacing, expect to pay £250–£400 or more once parts and labour are included. In rare cases where a more significant board assembly is needed, costs can exceed £450, but this is uncommon for this particular fault. Always check your boiler's warranty first — Remeha (distributed in the UK by Baxi) offers a 2-year product warranty plus 5 years on the heat exchanger, which may cover parts and labour if the boiler is still within that period.

My Remeha is also showing H.00.36 or H.01.06 alongside H.01.00 — what does that mean?

On Remeha Quinta Ace boilers it is not unusual for several blocking codes to appear together or in sequence, because one underlying fault — such as a communications bus problem — can trigger multiple related alerts simultaneously. H.00.36 and H.00.37 are typically water-pressure or flow-related blocking codes, while H.01.06 and H.01.07 tend to relate to sensor or component detection issues. Write down every code shown on the display and pass all of them to your Gas Safe engineer or to Remeha technical support — having the full list allows a much faster and more accurate diagnosis.

Affected models: Remeha Quinta Ace 30, Remeha Quinta Ace 45, Remeha Quinta Ace 65, Remeha Quinta Ace 90, Remeha Quinta Ace 115, Remeha Quinta Ace 135, Remeha Quinta Pro, Remeha Avanta Plus

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha H.01.00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →