Remeha H.01.07 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha H.01.07 fault code mean?

H.01.07 is a fault code appearing on Remeha boilers — most likely within the Quinta ACE or similar commercial range — that signals an abnormal operating condition requiring the boiler to shut down safely. The 'H' prefix on Remeha equipment typically indicates a model-specific or system-level fault, and the .01.07 sub-designation points toward an ignition, gas supply, or combustion-related issue within that fault family. The boiler will stop firing and lock out until the underlying problem is identified and resolved. Because H.01.07 is not publicly documented in Remeha's consumer-facing materials, the most reliable next step is to contact Remeha technical support on 0330 678 0140 with your exact model and the code displayed, or to book a Gas Safe registered engineer to diagnose the boiler in person.

Lockout — engineer likely May need a Gas Safe engineer 3 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that other gas appliances in the property are working DIY safe

    Turn on a gas hob ring or check another gas appliance. If nothing is working, the issue is likely a supply interruption — contact your gas supplier before calling an engineer.

  2. Check the boiler's system pressure DIY safe

    Look at the pressure gauge on the boiler front. It should read between 1.0 and 1.5 bar when the system is cold. If it is below 0.8 bar, top it up using the filling loop following the instructions in your boiler's user guide. Do not exceed 2.5 bar.

  3. Inspect the condensate pipe for freezing (winter months) DIY safe

    Locate the white plastic condensate pipe that exits the boiler and runs to an external drain or internal waste pipe. If it feels solid or you can see ice around it, thaw it carefully using warm (not boiling) water poured along its length, or wrap it in a warm cloth. Once thawed, attempt a reset.

  4. Reset the boiler once DIY safe

    Press and hold the reset button as described in your boiler manual. Allow the boiler to complete its full ignition cycle — this can take up to two minutes. If it lights and runs normally, monitor it over the next few hours. Limit resets to two or three attempts; repeated resetting without fixing the underlying fault can mask a serious problem.

  5. Do not attempt to inspect or adjust gas components Gas Safe engineer

    Working on the gas valve, burner assembly, ignition electrodes, flue, or any internal gas-carrying component requires Gas Safe registration. These parts must only be inspected and serviced by a qualified engineer.

  6. Do not attempt PCB or wiring repairs Gas Safe engineer

    The control board and associated wiring harness involve both mains voltage and gas control signals. Any intervention here must be carried out by a Gas Safe registered engineer with the appropriate Remeha technical training.

  7. Contact Remeha technical support or book a Gas Safe registered engineer Gas Safe engineer

    If the boiler has not recovered after the homeowner checks above, call Remeha technical support on 0330 678 0140 with your exact model name and the fault code shown on the display. Alternatively, book a Gas Safe registered engineer to attend, diagnose, and carry out any necessary repair. Because H.01.07 is a model-specific code not publicly documented, an engineer with access to Remeha's service documentation will be best placed to resolve it accurately.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£400, depending on the underlying cause.

Frequently asked questions

What does the H prefix mean on a Remeha fault code?

On Remeha commercial and Quinta ACE range boilers, the 'H' prefix typically indicates a model-specific or system-level fault condition that has caused the boiler to lock out for safety. Unlike the more common 'E' series codes used across Remeha's residential range, 'H' codes are associated with newer commercial platforms and often relate to gas supply, combustion, ignition, or PCB control issues. Because these codes are not publicly documented in consumer-facing materials, you will generally need to either contact Remeha on 0330 678 0140 or have a Gas Safe engineer consult the official service manual for your exact model.

Can I reset a Remeha H.01.07 fault myself?

Yes, a single reset attempt is a reasonable first step and is safe for a homeowner to carry out. Press the reset button and allow the boiler to complete its full start-up cycle. If it lights and runs normally, monitor it closely over the next day. However, if the boiler locks out again — or if you need to reset it repeatedly to keep it running — stop and call an engineer. Repeated resets without fixing the root cause can mask a developing fault and, in the case of gas-related issues, could be unsafe.

How much does it typically cost to repair a Remeha H.01.07 fault?

For the most common underlying causes — ignition electrode replacement, gas valve servicing or replacement, or fan repair — most homeowners pay in the region of £150 to £400 including parts and labour. A straightforward ignition component replacement at the lower end of that range, or a gas valve swap at the higher end, are the typical scenarios. If the fault turns out to involve the main PCB or control board, costs can rise to £400–£600 or more depending on the model, and a heat exchanger failure on a commercial unit can exceed that further still. Getting a diagnosis visit first (usually £50–£80) before committing to a repair is always advisable.

Is H.01.07 related to the Remeha H.02.05 or H.02.10 codes?

They appear to be part of the same fault code family used on Remeha's commercial and Quinta ACE range. H.02.10 is documented as relating to a blocked or defective gas valve, while H.02.05 has been reported in connection with a PCB failure requiring a circuit board replacement. H.01.07 sits in the same alphanumeric series, suggesting a related but distinct sub-fault — possibly in the ignition or combustion monitoring area. Because the precise definition of H.01.07 is not publicly available, an engineer with access to Remeha's technical documentation is the only reliable source for a definitive answer.

Affected models: Remeha Quinta ACE, Remeha Ace, Remeha commercial condensing boiler range

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha H.01.07 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →