Sime AL 09 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 09 fault code mean?

The AL 09 fault code (displayed as ALL 09 on some Sime models) means the boiler's flow switch has detected insufficient water circulation through the heating circuit. When circulation falls below the expected level, the boiler shuts down as a safety precaution to prevent the heat exchanger from overheating. If the condition persists for more than one minute, the boiler will pause for six minutes before attempting a restart. In plain terms, water is either not moving around your system at all, or not moving quickly enough for the boiler to consider it safe to fire.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the boiler pressure gauge DIY safe

    Look at the pressure gauge on the front of the boiler. It should read between 1 and 1.5 bar when the system is cold. If the needle is below 1 bar, the low water volume may be contributing to the circulation fault. Refer to your Sime manual and top up via the filling loop until the gauge reads around 1.2 bar, then attempt a reset.

  2. Reset the boiler (up to 2–3 times) DIY safe

    Press and hold the reset button as described in your Sime manual. If the boiler fires and runs normally, monitor it over the next few hours. If it locks out again with AL 09, do not keep resetting — move on to further checks.

  3. Bleed your radiators to remove airlocks DIY safe

    Turn off the heating and let the system cool. Using a radiator bleed key, open the bleed valve on each radiator (starting upstairs and working down) until water flows steadily with no air bubbles. Re-check the boiler pressure afterwards and top up if needed, as bleeding can cause a small pressure drop.

  4. Check all isolation and zone valves are fully open DIY safe

    Inspect any accessible valves on the pipework near the boiler and around the system. A valve handle that is perpendicular to the pipe is closed; it should be in line with the pipe to be open. If any zone valves are motorised, confirm they are not stuck shut.

  5. Have a Gas Safe engineer inspect and test the circulation pump Gas Safe engineer

    An engineer will check whether the pump is receiving power, running at the correct speed, and actually generating flow. A seized pump can sometimes be freed if caught early, but a failed pump will need replacing. Pump replacement on a Sime boiler typically costs £150–£350 including parts and labour.

  6. Have a Gas Safe engineer clean or replace the system filter Gas Safe engineer

    A heavily silted magnetic filter can choke the system enough to cause the AL 09 fault. An engineer can clean or replace this as part of a service visit. If there is no filter fitted, they may recommend installing one to protect the boiler long-term.

  7. Have a Gas Safe engineer inspect and test the flow switch Gas Safe engineer

    A qualified engineer can test the flow switch electrically without fully dismantling it. If it is found to be stuck due to debris, it can sometimes be cleaned; if it has failed, replacement parts are relatively inexpensive and the total repair including call-out and labour typically falls in the £80–£150 range.

  8. Have a Gas Safe engineer check the wiring and PCB Gas Safe engineer

    If the pump, filter, and flow switch have all been checked and the fault persists, an engineer will inspect the wiring harness for damage or corrosion and test the PCB. PCB replacement is a significant cost (typically £200–£450 including labour) so an engineer may advise whether repair is economical given the age of the boiler.

  9. Call a Gas Safe registered engineer if the fault has not cleared Gas Safe engineer

    If the AL 09 code returns after the homeowner checks above, or you are unsure about any step, contact a Gas Safe registered engineer. You can verify any engineer's registration at gassaferegister.co.uk. Do not remove the boiler casing or attempt internal repairs yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£350, depending on the underlying cause.

Frequently asked questions

Can I fix the Sime AL 09 fault myself?

Some initial checks are safe for a homeowner: topping up the system pressure via the filling loop, bleeding radiators, and checking that any accessible valves are fully open. If those steps do not clear the fault, the likely causes — a faulty pump, blocked filter, or failed flow switch — all require a Gas Safe registered engineer to diagnose and repair safely. Do not remove the boiler casing or attempt internal work yourself.

What is the difference between AL 09 and ALL 09 on a Sime boiler?

They are the same fault. Some Sime display panels show the code as AL 09 while others, particularly older or larger models, display it as ALL 09 due to differences in the screen format. Both indicate that the flow switch has detected insufficient water circulation through the heating circuit.

How much does it cost to fix a Sime AL 09 fault in the UK?

The cost depends entirely on the root cause. Simple fixes like topping up pressure or bleeding radiators cost nothing. Cleaning or replacing a flow switch typically runs £80–£150 including a Gas Safe engineer's call-out and labour. Replacing the circulation pump is the most common paid repair and usually costs £150–£350 all-in. In rare cases where the PCB is at fault, replacement can cost £200–£450 or more — at which point it is worth considering the age of the boiler and whether a replacement is better value overall.

My Sime boiler keeps showing AL 09 after I reset it — what should I do?

Resetting the boiler two or three times is reasonable if you have just made a change such as topping up the pressure or bleeding a radiator. However, if the fault returns each time without any improvement, continued resetting will not solve the underlying problem and may cause further wear. Stop resetting and book a Gas Safe registered engineer to carry out a proper diagnosis. Persistent AL 09 faults most commonly point to a circulation pump that is on its way out, a blocked system filter, or a faulty flow switch.

Affected models: Sime Friendly, Sime 90, Sime 102, Sime Format, Sime Murelle, Sime Brava

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 09 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →