Sime AL 07 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 07 fault code mean?

The AL 07 code appears on Sime boilers when the built-in safety thermostat (TS) has triggered a protective shutdown. This thermostat acts as a last line of defence against overheating — when it detects that temperatures inside the boiler have exceeded safe limits, or that a related component has failed, it cuts operation and locks the boiler out. On Sime displays, the fault is shown as "AL" followed by "07", accompanied by a red light bar. The boiler will not restart until the underlying cause has been identified and the fault is cleared. Because overheating can cause permanent damage to the heat exchanger, this code should always be investigated promptly rather than repeatedly reset.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check and restore system pressure if necessary DIY safe

    Look at the pressure gauge on the front of the boiler. It should read between 1.0 and 1.5 bar when the system is cold. If it is below 1 bar, use the filling loop to top it up slowly to around 1.2 bar. Low pressure alone can impair circulation and contribute to overheating faults.

  2. Bleed the radiators to remove trapped air DIY safe

    Using a radiator bleed key, open the bleed valve on each radiator starting with the one furthest from the boiler. Hold a cloth underneath and release air until water begins to flow steadily, then close the valve. Re-check boiler pressure afterwards and top up again if needed, as bleeding can lower it.

  3. Reset the boiler (no more than two or three times) DIY safe

    Once you have topped up the pressure and bled the radiators, attempt a boiler reset using the reset button or procedure described in your user manual. If the AL 07 code clears and the boiler runs normally, monitor it over the next 24 hours. If the fault returns, do not keep resetting — repeated resets on an overheating fault can cause heat exchanger damage.

  4. Have a Gas Safe engineer inspect the circulating pump Gas Safe engineer

    A qualified engineer will check whether the pump impeller is blocked, sticking, or has seized. They may be able to free a seized impeller or, if the pump has failed, replace it. This is not a homeowner task as it involves draining part of the system and working on internal components.

  5. Have a Gas Safe engineer test the safety thermostat and its wiring Gas Safe engineer

    The engineer will check the thermostat sensor connections for corrosion or looseness and test the component electrically. A faulty or incorrectly reading safety thermostat will be replaced. Wiring faults will be repaired at the same time.

  6. Have a Gas Safe engineer check the NTC thermistor Gas Safe engineer

    The engineer will use diagnostic equipment to verify that the NTC thermistor is reading temperatures accurately. A drifting or failed thermistor is relatively straightforward to replace and often resolves AL 07 faults that return after initial checks.

  7. If scale or sludge is suspected, arrange a powerflush Gas Safe engineer

    A Gas Safe engineer or heating specialist can carry out a powerflush to clear sludge and scale from the system. Inhibitor should be added afterwards to protect against future corrosion. This work does not require Gas Safe registration itself but should be arranged as part of the overall repair to prevent the fault recurring.

  8. Call a Gas Safe registered engineer if the fault persists or recurs Gas Safe engineer

    If the AL 07 fault continues after the above checks, or if you are not confident performing even the homeowner steps, contact a Gas Safe registered engineer. Overheating faults that are left unresolved risk permanent heat exchanger damage, which is a significantly more expensive repair. You can find your nearest Gas Safe engineer at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Is it safe to keep resetting my Sime boiler when AL 07 appears?

No — you should attempt a reset once or twice to see whether the fault clears after straightforward checks such as topping up pressure or bleeding radiators. However, if AL 07 returns, stop resetting. This code indicates a safety thermostat intervention, and repeated resets on a boiler that is genuinely overheating can cause lasting damage to the heat exchanger, turning what might have been a £150 repair into one costing £500 or more.

Could a frozen condensate pipe cause the AL 07 fault on a Sime boiler?

Unlikely. A frozen condensate pipe typically produces its own specific fault code related to ignition or flue problems rather than an overtemperature lockout. AL 07 is specifically linked to the safety thermostat circuit. That said, if you are also seeing condensate-related symptoms in very cold weather, you can carefully thaw the external condensate pipe with warm (not boiling) water, then reset. If AL 07 persists, the thermostat circuit itself needs professional attention.

How much does it typically cost to fix a Sime AL 07 fault?

For the most common causes — pump issues, sensor faults, or trapped air — most homeowners pay between £120 and £380 including parts and labour. A safety thermostat or NTC thermistor replacement is towards the lower end of that range. A pump replacement sits in the middle. If scale or sludge is the underlying cause, add the cost of a powerflush (typically £300–£500 as a standalone job). In rare cases where prolonged overheating has damaged the heat exchanger, costs can reach £600–£900 or more — another reason not to ignore this fault code or keep resetting without investigation.

How do I find a Gas Safe engineer to fix my Sime boiler?

You can search the official register at gassaferegister.co.uk by postcode. Always ask to see the engineer's Gas Safe ID card before work begins — it shows which gas appliances they are qualified to work on. For Sime boiler repairs, look for engineers experienced with European boiler brands. Some Sime approved service agents can also be located through Sime's UK distributor.

Affected models: Sime Brava Slim HE, Sime ALU HE, Sime Format HE, Sime Murelle HE, Sime Murelle Revolution

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 07 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →