Sime AL 04 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 04 fault code mean?

The AL 04 code appears on Sime boilers when the control board loses confidence in the readings from the domestic hot water (DHW) temperature sensor — also known as an NTC thermistor or temperature probe. This small component monitors the temperature of the hot water circuit by changing its electrical resistance as the water temperature rises or falls. When the PCB detects a reading that is implausible, inconsistent, or completely absent, it triggers AL 04 and locks the boiler out as a protective measure. The boiler will not restart until the underlying sensor issue is resolved.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once DIY safe

    Press and hold the reset button on your Sime boiler for the required time as shown in your user guide. A one-off reset can clear a transient signal glitch. Do not attempt more than two or three resets in succession — persistent AL 04 after resetting means a physical fault needs attention.

  2. Check that the boiler has power and the gas supply is on DIY safe

    Confirm the boiler's mains switch is on, the consumer unit has not tripped, and the gas isolation valve at the meter is in the open position. These simple checks rule out unrelated supply issues before calling an engineer.

  3. Arrange for a Gas Safe engineer to inspect the DHW sensor wiring Gas Safe engineer

    An engineer will isolate the appliance from mains power and close the gas supply before opening the casing. They will check each connector on the DHW sensor circuit for corrosion, loose pins, or chafed cable. Reseating or replacing a corroded connector can sometimes clear the fault at minimal cost.

  4. Have the engineer test the DHW NTC sensor with a multimeter Gas Safe engineer

    The sensor's resistance is measured and compared against the manufacturer's specification at a known water temperature. An out-of-range reading confirms the sensor has failed and needs replacement. This is a straightforward test that takes only a few minutes.

  5. Replace the DHW NTC thermistor if it has failed Gas Safe engineer

    Genuine or compatible Sime DHW sensors are relatively inexpensive parts. The engineer will fit the correct replacement, reseal any connections, and power the boiler back up to verify the fault code has cleared and hot water is functioning normally.

  6. Have the PCB investigated if AL 04 persists after a new sensor Gas Safe engineer

    If the fault code returns with a confirmed-good sensor in place, the control board itself is the likely culprit. PCB diagnosis and replacement is specialist work and the most costly outcome of an AL 04 fault. Your engineer may advise whether repair or boiler replacement is more economical at this stage.

  7. Call a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    All work beyond the basic homeowner checks above — including opening the boiler casing, testing components, and replacing parts — must be carried out by a Gas Safe registered engineer. It is a legal requirement in the UK and essential for your safety and insurance.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£220, depending on the underlying cause.

Frequently asked questions

Can I fix Sime AL 04 myself?

The only safe DIY steps are resetting the boiler once or twice and confirming your gas supply and power are on. Everything else — opening the casing, testing the sensor with a multimeter, and replacing components — must be done by a Gas Safe registered engineer. Attempting internal boiler repairs without Gas Safe registration is illegal and potentially dangerous.

How much does it cost to fix a Sime AL 04 fault in the UK?

A straightforward DHW sensor replacement typically costs £100–£220 all-in, covering the engineer's call-out, around an hour of labour, and the sensor part itself. If the PCB turns out to be the problem, the board alone can cost £200–£350 in parts, pushing the total bill significantly higher. Getting a written quote before work starts is always advisable.

Will the boiler produce any hot water while AL 04 is showing?

No. Because AL 04 is a lockout fault, the boiler shuts down completely and will not fire up for central heating or domestic hot water until the fault is cleared and the boiler successfully restarted. You will need to arrange alternative hot water arrangements until an engineer has resolved the issue.

Could a boiler service have prevented AL 04?

Quite possibly, yes. An annual service includes inspecting sensor connections and checking component readings, so a corroded terminal or a sensor drifting out of specification can be caught before it causes a full lockout. Keeping your boiler on a regular service schedule is the most cost-effective way to avoid unexpected breakdowns.

Affected models: Sime Brava Slim HE, Sime Brava Slim BF, Sime Brava One, Sime ALU HE Series

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 04 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →