Sime AL 01 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 01 fault code mean?

The AL 01 fault code on a Sime boiler signals that the water pressure within the central heating circuit has dropped below the minimum safe operating level. When the boiler detects this condition, it locks out — shutting itself down to prevent damage — and the display shows 'AL 01' alongside a red light bar. System pressure on a Sime boiler should normally sit between 1.0 and 1.5 bar when cold. Because AL 01 is a relatively broad code, the underlying cause can vary, and Sime's own documentation recommends qualified technical assistance to pinpoint the exact fault on the boiler in front of you.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the pressure gauge and top up via the filling loop DIY safe

    With the boiler switched off and cool, locate the filling loop — typically a braided silver hose with one or two valves beneath the boiler. Open the valve(s) slowly, watching the pressure gauge, until the needle reaches between 1.0 and 1.5 bar. Close both valves firmly. Do not overshoot 2.0 bar. Switch the boiler back on and allow it to fire up normally.

  2. Reset the boiler DIY safe

    Once pressure has been restored, the boiler may need a manual reset. Refer to your Sime manual for the reset button location — on most models it is held for a few seconds until the display clears. If the boiler restarts and runs normally, monitor the pressure gauge over the next few days to see if pressure holds steady.

  3. Monitor pressure over the following weeks DIY safe

    If the pressure remains stable above 1.0 bar and AL 01 does not return, you may have resolved a one-off pressure drop. However, if you need to top up more than once a month, or if the pressure drops rapidly within days, this points to an underlying fault that needs professional attention.

  4. Inspect visible pipework and radiator connections for leaks DIY safe

    Walk around the property and check accessible pipework, radiator valves and any visible joints for dampness, rust staining or mineral deposits, which can indicate a slow weep. Check under the boiler casing for signs of dripping. Do not open the boiler casing yourself.

  5. Arrange a Gas Safe registered engineer to investigate further Gas Safe engineer

    If pressure keeps dropping, or if you cannot identify a visible leak, contact a Gas Safe registered engineer. They will pressure-test the system, inspect the expansion vessel pre-charge, check the auto air vent, and assess the heat exchanger for any internal splitting. All internal boiler work — including expansion vessel replacement, AAV replacement, and any pipework repairs within the boiler — must be carried out by a qualified professional.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£450, depending on the underlying cause.

Frequently asked questions

Can I fix Sime AL 01 myself by topping up the pressure?

Topping up the pressure via the filling loop is a perfectly safe DIY task, and if a one-off pressure drop is the cause, this may resolve AL 01 straight away. However, if the pressure drops again within days or weeks, there is an underlying fault — a leak, a failed expansion vessel, or another component issue — that requires a Gas Safe registered engineer to diagnose and fix. Do not repeatedly top up and ignore the root cause, as running a leaking system can cause further damage.

How often should I need to top up my Sime boiler pressure?

On a healthy sealed heating system, you should rarely need to top up pressure at all — perhaps once a year at most, usually after bleeding radiators. If you are topping up more than once a month, or if the pressure drops rapidly, this is a sign of a leak or a failing expansion vessel and you should book an engineer promptly.

What does it cost to repair AL 01 on a Sime boiler in the UK?

For the most common causes, typical repair costs range from around £150 to £450 including parts and labour. Re-pressurising during a service call sits at the lower end. Expansion vessel recharging or replacement usually costs £180–£350. Leak tracing and repairs vary depending on where the leak is. A split plate heat exchanger is a more significant repair and can cost £400–£700 or more — if that is suspected on an older boiler, it is worth getting a replacement quote alongside a repair quote.

Why does my Sime boiler keep losing pressure even after I top it up?

Recurring pressure loss almost always points to either a water leak somewhere in the system, a failed expansion vessel diaphragm, or — less commonly — a cracked heat exchanger allowing cold mains water to enter and then escape. A Gas Safe engineer can pressure-test your system and inspect the expansion vessel pre-charge to identify which component is responsible. Ignoring repeated pressure loss risks further component damage and, in the case of a leak, potential water damage to your property.

Affected models: Sime Brava One ErP, Sime Format, Sime Murelle, Sime Metropolis, Sime Friendly

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 01 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →